01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DIDOMUR S49-03

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Refractory product

Manufacturers & Suppliers

RHI Magnesita GmbH logo

RHI Magnesita GmbH

manufacturer

Kranichbergstrasse 6, 1120 Vienna, Austria

+43 50213 0

http://rhimagnesita.com

Emergency Contacts

Emergency Contact

+43 502 13 5426

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Unshaped product for refractory use on basis of

Chemical Name CAS Number Concentration Hazardous
alumina silicate (kyanite) EC: 215-106-4 1302-76-7 70 - 80% No
aluminium silicate EC: 215-113-2 1302-93-8 5 - 10% No
quartz (SiO2) EC: 238-878-4 14808-60-7 2.5 - 5% Yes
fumes, silica EC: 273-761-1 69012-64-2 5 - 10% No

In order to avoid dust during installation, the technical possibilities available at the site should be used. Please observe the instructions for personal protective equipment given in section 8. For the wording of the listed hazard phrases refer to section 16. Free SILICA free silica > 2,5%

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

No special measures required.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Workers must be informed of the presence of crystalline silica and trained in the proper use and handling of this product as required under applicable regulations

Storage

Store only in the original receptacle. Protect from humidity and water.

Fire prevention

The product is not flammable

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Use gloves of stable material (e.g. Nitrile) - if necessary tricoted to improve the wearability. After each cleaning use treatment creams, for very dry skin greasy ointments. Material of gloves Use gloves of stable material (e.g. Nitrile) - if necessary tricoted to improve the wearability. Penetration time of glove material not applicable

Eyes

Safety glasses

Respiratory

Filter P2. Use suitable respiratory protective device in case of insufficient ventilation. Recommended filter device for short term use: Filter P2

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
Dark
Colour Intensity
---
Form
Solid
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not applicable.
Melting Point
---
Boiling Point
---
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable.
Vapor Pressure
Not applicable.
Vapor Density
Not applicable.
Relative Density
Not determined.
Bulk Density
---
Density
Not determined
Flammability
Product is not flammable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not applicable.
Kinematic Viscosity
Not applicable.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used and stored according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known

Avoid

No decomposition if used and stored according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Aquatic toxicity: No further relevant information available.

No further relevant information available regarding aquatic toxicity.

12.2 Persistence and degradability

No further relevant information available.

No further relevant information available.

12.3 Bioaccumulative potential

No further relevant information available.

12.4 Mobility in soil

No further relevant information available.

No further relevant information available.

12.5 Results of PBT and vPvB assessment

PBT: Not applicable. vPvB: Not applicable.

The substance is not classified as PBT or vPvB.

12.6 Other adverse effects

No further relevant information available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Disposal must be made according to official regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DIDOMUR S49-03?

The signal word is no signal word.

What is the physical form of DIDOMUR S49-03?

DIDOMUR S49-03 is a solid with dark color. It has characteristic odor.

What is DIDOMUR S49-03 used for?

Refractory product