Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DOMOPOL 5176 60SA
- Product Code
- 479343
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
HSE dept.
+386 (1) 722 4383
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Solution of saturatedpolyester resin in organic solvents.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| hydrocarbons, C9 aromatics EC: 918-668-5 | --- | 30 - 49.99% | Yes |
| reaction mixture of ethylbenzene, m-xylene and p-xylene EC: 905-562-9 | --- | 1 - 2.99% | Yes |
The classification for the product was made on basis of actual content of components. The cointained substances are shown in intervals. In case of inspection check (control of classification) we are ready to send to inspection bodies on their request the actual content of individual components.
First Aid Measures
Emergency procedures for chemical exposure incidents
If there are any symptoms transfer the victim to clean air.
Remove contaminated clothing. Wash skin with soap and water. Do not use organic solvents or thinners.
Flush eyes with water to removeproduct residue.
Do not eat. Rinse mouth with water. Do not induce vomiting.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, powder, carbon dioxide, inert gas or INERGEN FM 200 (started phase fire fighting), water fog.
Open water jet, unless USED ONLY for water mist to cool containers with flammable products.
The possibility of formation man harmful gases and thick smoke during the fire.
Remove all possible sources of ignition: open flame, lit cigarette, sparkling of tools and equipment. Close packagings with product.
Firefighter Protection
The use of protective mask with filterAis mandatory.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Prevent leakage into water, water dams, cellars, caves or sewage system. Prevent outflow into water, water dams, cellars, caves or sewage system and vapour accumulation in closed rooms.
Absorb the outflown product and mix it with soil, sand or other absorptive materials for liquids.
Materials: soil, sand or other absorptive materials for liquids
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not smoke, drink or eat while handling the product. Do not breathe vapors, avoid contact with skin and eyes. At work wear cotton overalls or coveralls, nitrile rubber gloves and safety glasses with side shields.
Store in tightly closed vessels in a cool and ventilated room. Store in an upright position.
Do not smoke, drink or eat while handling the product.
Prevent contact with hot objects, sparkles, flame and sources of ignition. During the pumping static electrification may occur. Emptying of static electrification, which could cause fire. At the decanting of larger quantities assure conductivity with binding and earthing of complete equipment. In the warehouse there should be no tools or machines, which are the source of sparkling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Atseveral contacts with the product use gloves made of nytril rubber with thickness 0,40 mm, in contact with drops of product (minor contacts) the gloves made of nytril rubber of thickness 0,11 mm.
At the low concentrations in the air wear protective goggles, at high concentrations theprotective mask for the whole face.
When used in confined spaces, prolongedwork,wearprotective mask for the whole face with filter"A".In case that the oxygen concentration in the air of work room falls under 17 %, use independent respirator with an open circle on the compressed air.
In normal conditions wear clothes made of cotton and suitable footwear. In case the possibility of outflow is high, use the clothes and footwear resistant to chemicals(PVC,rubber).
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under conditions in accordance with the instructions and proper storage.
Stable - when used in accordance with the instructions.
The presence of open flame or hazardous materials.
Avoid contact of product with heat, sparks, flames and other ignition sources.
hazardous materials
No data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The product leftovers, waste and useless packaging should be handled in accordance with the Regulations on processing of special and dangerous waste (dir. 91/689/EEC, dir. 2000/532/EC).
The recommended degradation method is the use of the controlled high temperature incineration or disposal to the deposits for dangerous substances.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1866
- Shipping Name
- RESIN SOLUTION
- Transport Class
- 3
- Packing Group
- III
Transport with respecting transport labels and the requests of transportation legislation.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This Safety Data Sheet has been prepared in accordance with a comprehensive chemicals legislation - REACH Regulation on chemicals and the Regulation for classification, labeling and packaging (CLP/GHS).
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DOMOPOL 5176 60SA?
The signal word is warning.
What is the physical form of DOMOPOL 5176 60SA?
DOMOPOL 5176 60SA is a liquid appearing as liquid . It has specific for organic solvents odor.
What is the solubility of DOMOPOL 5176 60SA?
Insoluble
What are the hazard statements for DOMOPOL 5176 60SA?
This substance has 4 hazard statements:
- H226: Flammable liquid and vapour.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with longlastingeffects.