NextSDS Logo
Safety Data Sheet EN

Fluoride standard solution 1000 g/ml for IC (Ion HIQU)

CAS 7681-49-4
EC 231-667-8

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Fluoride standard solution 1000 g/ml for IC (Ion HIQU)
Product Code
CL01.0611
Chemical Name
Sodium fluoride a.r.

Regulatory Identifiers

CAS Number
7681-49-4 Check regulations →
EC Number
231-667-8 Check regulations →

Identified Uses

Reagent for analysis In compliance with the conditions described in the annex to this safety data sheet.

Manufacturers & Suppliers

C

CHEM-LAB NV

manufacturer

Industriezone De Arend 2, B-8210 ZEDELGEM - BELGIUM

Emergency Contacts

Emergency Contact

00 (32) 50.28.83.20

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Hazardous Ingredients: Name according to EC directives:

Chemical Name CAS Number Concentration Hazardous
Sodium fluoride a.r. EC: 231-667-8 7681-49-4 0.1 - 1% Yes
Deionized Water EC: 231-791-2 7732-18-5 90% No

Notes

For the full text of H-Phrases mentioned in this Section, see Section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Fresh air.

Skin contact

Wash off with plenty of water. Remove contaminated clothing.

Eye contact

Rinse out with plenty of water with the eyelid held wide open.

Ingestion

Never give anything by mouth to an unconscious person. Immediately make victim drink water (two glasses at most). Call in physician.

Immediate Medical Attention

No data available

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Protective clothing should be selected specificlly for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1

Hands

Required.

Eyes

Required.

Respiratory

Required when vapours/aerosols/dust are generated. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Required.

Environmental

Do not allow to enter sewerage system.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Dynamic Viscosity
---
Metal Corrosion
---
Density
1,00 g/ml
Upper Explosive Limit
---
Decomposition Temperature
---
Physical State Data
liquid
Molecular Weight
41.99 g/mol
Kinematic Viscosity
---
Boiling Point
100C
Relative Evaporation Rate
---
Solubility In Fat
---
Properties Status
---
Odor Threshold
---
Colour Intensity
---
State Under Standard Conditions
---
Vapor Pressure
---
Crystallisation Point
---
Relative Density
---
Melting Point
0C
Appearance
Liquid, Colourless
Explosive Limits
---
Solubility
---
Voc Content
---
Freezing Point
---
Form
Liquid
Physical State
Liquid
Evaporation Rate
---
Solidification Point
---
Odor
Odourless
Flash Point
---
Solubility In Water
soluble
Cloud Point
---
Flammability
---
Ph
pH > 11
Lower Explosive Limit
---
Partition Coefficient
---
Bulk Density
---
Colour
Colourless
Auto Ignition Temperature
---
Softening Point
---
Vapor Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

no

IMDG

no

IATA

no

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Fluoride standard solution 1000 g/ml for IC (Ion HIQU)?

The signal word is no signal word.

What is the physical form of Fluoride standard solution 1000 g/ml for IC (Ion HIQU)?

Fluoride standard solution 1000 g/ml for IC (Ion HIQU) is a liquid appearing as liquid, colourless with colourless color. It has odourless odor.

What is Fluoride standard solution 1000 g/ml for IC (Ion HIQU) used for?

Reagent for analysis In compliance with the conditions described in the annex to this safety data sheet.

What is the melting point of Fluoride standard solution 1000 g/ml for IC (Ion HIQU)?

The melting point is 0C and the boiling point is 100C.

Compliance Scanner

Scan your compliance