NextSDS Logo
Safety Data Sheet EN

Zirconium standard solution 1000 µg/ml (Plasma HIQU)

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Zirconium standard solution 1000 µg/ml (Plasma HIQU)
Product Code
CL01.2632

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

A

AnalytiChem Belgium NV

manufacturer

Industriezone "De Arend" 2, B-8210 ZEDELGEM - BELGIUM

(32)-50-288320

A

AnalytiChem Belgium NV

manufacturer

Industriezone "De Arend" 2, B-8210 Zedelgem, BELGIUM

+32 50 28 83 20

Emergency Contacts

Emergency Contact

00 (32) 50.28.83.20

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1A H317

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.

Precautionary Statements

P280 Wear protective gloves, protective clothing, eye protection, face protection.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrochloric acid 34- 37% (Pico-Pure) 7647-01-0 2 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Fresh air.

Skin contact

Wash off with plenty of water. Remove contaminated clothing.

Eye contact

Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open.

Ingestion

Never give anything by mouth to an unconscious person. Immediately make victim drink water (two glasses at most).

Immediate Medical Attention

Immediately call an ophthalmologist. Call in physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In adaption to materials stored in the immediate neighbourhood.

Unsuitable media

Prevent fire-fighting water from entering surface water or groundwater.

Specific hazards

Non-combustible. Ambient fire may liberate hazardous vapours.

Instructions

Keep a safety distance.

Firefighter Protection

Do not stay in dangerous zone without self-contained breathing apparatus. In order to avoid contact with skin, keep a safety distance and wear suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not inhale vapours/aerosols. Avoid substance contact. Ensure supply of fresh air in enclosed rooms.

Environmental

Do not allow to enter sewerage system.

Cleanup methods

place in a closed container for disposal

Materials: sand or vermiculite

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures necessary. The product should be handled with the care usual when dealing with chemicals.

Storage

Closed in a cool ventilated place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1. Work under hood.

Hands

Required.

Eyes

Required.

Respiratory

Required when vapours/aerosols are generated. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Not required.

Environmental

Do not allow to enter sewerage system.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Partition Coefficient
---
Crystallisation Point
---
Flammability
---
Auto Ignition Temperature
---
Relative Density
---
Molecular Weight
---
Density
1,05 g/ml
Odor Threshold
---
Relative Evaporation Rate
---
Solidification Point
---
Colour
Colourless
Solubility In Fat
---
Appearance
---
Evaporation Rate
---
Flash Point
---
Freezing Point
---
State Under Standard Conditions
---
Physical State Data
liquid
Dynamic Viscosity
---
Decomposition Temperature
---
Kinematic Viscosity
---
Softening Point
---
Melting Point
-25°C
Lower Explosive Limit
---
Ph
pH < 1
Bulk Density
---
Metal Corrosion
---
Odor
Odourless
Upper Explosive Limit
---
Physical State
liquid
Boiling Point
108.6 °C
Solubility In Water
soluble
Properties Status
---
Colour Intensity
---
Vapor Pressure
---
Form
Liquid
Cloud Point
---
Solubility
---
Voc Content
---
Vapor Density
---
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No further relevant information available.

Reactivity

See section 10.3

Hazardous reactions

Dangerous reactions are not expected handling the product according to its intended use.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No further relevant information available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1789
Shipping Name
Hydrochloric acid
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Zirconium standard solution 1000 µg/ml (Plasma HIQU)?

The signal word is warning.

What is the physical form of Zirconium standard solution 1000 µg/ml (Plasma HIQU)?

Zirconium standard solution 1000 µg/ml (Plasma HIQU) is a liquid with colourless color. It has odourless odor.

What is Zirconium standard solution 1000 µg/ml (Plasma HIQU) used for?

Reagent for analysis

What are the hazard statements for Zirconium standard solution 1000 µg/ml (Plasma HIQU)?

This substance has 1 hazard statement:

  • H317: May cause an allergic skin reaction.

What is the melting point of Zirconium standard solution 1000 µg/ml (Plasma HIQU)?

The melting point is -25°C and the boiling point is 108.6 °C.