Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Zirconium standard solution 1000 µg/ml (Plasma HIQU)
- Product Code
- CL01.2632
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
AnalytiChem Belgium NV
manufacturer
Industriezone "De Arend" 2, B-8210 ZEDELGEM - BELGIUM
(32)-50-288320
AnalytiChem Belgium NV
manufacturer
Industriezone "De Arend" 2, B-8210 Zedelgem, BELGIUM
+32 50 28 83 20
Emergency Contacts
Emergency Contact
00 (32) 50.28.83.20
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrochloric acid 34- 37% (Pico-Pure) | 7647-01-0 | 2 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air.
Wash off with plenty of water. Remove contaminated clothing.
Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open.
Never give anything by mouth to an unconscious person. Immediately make victim drink water (two glasses at most).
Immediate Medical Attention
Immediately call an ophthalmologist. Call in physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In adaption to materials stored in the immediate neighbourhood.
Prevent fire-fighting water from entering surface water or groundwater.
Non-combustible. Ambient fire may liberate hazardous vapours.
Keep a safety distance.
Firefighter Protection
Do not stay in dangerous zone without self-contained breathing apparatus. In order to avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not inhale vapours/aerosols. Avoid substance contact. Ensure supply of fresh air in enclosed rooms.
Do not allow to enter sewerage system.
place in a closed container for disposal
Materials: sand or vermiculite
Related Products
Similar products with comparable safety profiles
Zinc standard solution 1000 µg/ml (Plasma HIQU)
---
Iron standard solution 1000 µg/ml (Plasma HIQU)
---
Chromium standard solution 1000 µg/ml (Plasma HIQU)
---
Calcium standard solution 1000 µg/ml (Plasma HIQU)
---
Cobalt standard solution 1000 µg/ml (Plasma HIQU)
---
Copper standard solution 1000 µg/ml (Plasma HIQU)
---
Sodium standard solution 1000 µg/ml (Plasma HIQU)
---
Molybdenum standard solution 1000 µg/ml (Plasma HIQU)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures necessary. The product should be handled with the care usual when dealing with chemicals.
Closed in a cool ventilated place.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1. Work under hood.
Required.
Required.
Required when vapours/aerosols are generated. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Not required.
Do not allow to enter sewerage system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No further relevant information available.
See section 10.3
Dangerous reactions are not expected handling the product according to its intended use.
No further relevant information available.
No further relevant information available.
No further relevant information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1789
- Shipping Name
- Hydrochloric acid
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Zirconium standard solution 1000 µg/ml (Plasma HIQU)?
The signal word is warning.
What is the physical form of Zirconium standard solution 1000 µg/ml (Plasma HIQU)?
Zirconium standard solution 1000 µg/ml (Plasma HIQU) is a liquid with colourless color. It has odourless odor.
What is Zirconium standard solution 1000 µg/ml (Plasma HIQU) used for?
Reagent for analysis
What are the hazard statements for Zirconium standard solution 1000 µg/ml (Plasma HIQU)?
This substance has 1 hazard statement:
- H317: May cause an allergic skin reaction.
What is the melting point of Zirconium standard solution 1000 µg/ml (Plasma HIQU)?
The melting point is -25°C and the boiling point is 108.6 °C.