Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Isocil™ Ultra 1.5
- Chemical Name
- Isocil™ Ultra 1.5
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Biocidal product
Manufacturers & Suppliers
Lonza Ltd
manufacturer
Muenchensteinerstrasse 38 CH-4002 Basel, Switzerland
+41 61 316 81 11
Emergency Contacts
Lonza Ltd
+41 61 313 94 94
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 5-Chloro-2-methyl-2H-isothiazol-3-one and 2-Methyl-2H-isothiazol-3-one (mixture 3:1) | 55965-84-9 | 1.5% | Yes |
| Magnesium nitrate EC: 233-826-7 | 10377-60-3 | 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If breathing is irregular or stopped, administer artificial respiration. Give oxygen. Call a physician immediately.
Take off all contaminated clothing immediately. After contact with skin, wash immediately with plenty of soap and water. Call a physician immediately.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Call a physician immediately.
Call a physician immediately. Clean mouth with water and drink afterwards plenty of water. Do not induce vomiting without medical advice. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry powder, Water spray, Foam
Heating or fire can release toxic gas.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not flush into surface water or sanitary sewer system.
collect with non-combustible absorbent material, and place in container for disposal according to local / national regulations (see section 13).
Materials: non-combustible absorbent material (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes.
Keep container tightly closed. To maintain product quality, do not store in heat or direct sunlight. Keep in a dry, cool and well-ventilated place.
Take precautionary measures against static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Suitable material : Nitrile rubber Break through time : > 480 min Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).
Tightly fitting safety goggles Face-shield
In the case of vapour formation use a respirator with an approved filter. Respirator with a vapour filter (EN 141) Respirator with ABEK filter.
Choose body protection according to the amount and concentration of the dangerous substance at the work place. Rubber or plastic apron Rubber or plastic boots
Do not flush into surface water or sanitary sewer system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Stable under recommended storage conditions.
Hazardous polymerisation does not occur.
no data available
Reducing agents, Oxidizing agents, Amines
Nitrogen oxides (NOx), Hydrogen chloride gas, Sulphur oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The mixture contains no substances considered to be persistent, bioaccumulating and toxic (PBT) or very persistent and very bioaccumulating (vPvB).
12.6 Other adverse effects
Do not flush into surface water or sanitary sewer system. Discharge into the environment must be avoided.
Toxicity
Persistence and degradability
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations. Contact manufacturer.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3265
- Shipping Name
- Corrosive liquid, acidic, organic, n.o.s. (5-Chloro-2-methyl-4-isothiazolin-3-one)
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This safety datasheet complies with the requirements of Regulation (EC) No. 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Isocil™ Ultra 1.5?
The signal word is danger.
What is the physical form of Isocil™ Ultra 1.5?
Isocil™ Ultra 1.5 is a liquid with light yellow color. It has pungent odor.
What is Isocil™ Ultra 1.5 used for?
Biocidal product
What are the hazard statements for Isocil™ Ultra 1.5?
This substance has 3 hazard statements:
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of Isocil™ Ultra 1.5?
The melting point is -3 °C and the boiling point is ca. 100 °C.