NextSDS Logo
L-

L-Lysine 50%, Solution

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
L-Lysine 50%, Solution
Product Code
3091

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial, Manufacturing or Laboratory use

Overview

L-Lysine 50%, Solution is a clear, colorless liquid substance commonly used industrial, manufacturing or laboratory use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Columbus Chemical Industries, Inc.

manufacturer

๐Ÿ“

N4335 Temkin Rd. Columbus, WI. 53925

๐ŸŒ

US

๐Ÿ“ž

920-623-2140

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

800-424-9300

๐ŸŒ

US

๐Ÿ•’

24 Hours/Day, 7 Days/Week

CHEMTREC

๐Ÿ“ž

703-527-3887

๐ŸŒ

US

๐Ÿ•’

24 Hours/Day, 7 Days/Week

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
L-Lysine
EC: 200-294-2
56-87-1 50% โœ“ Non-hazardous
Water
EC: 231-791-2
7732-18-5 Not specified โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move casualty to fresh air and keep at rest. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention if necessary.

๐Ÿ–๏ธ Skin Contact

Wash off with soap and plenty of water.

๐Ÿ‘๏ธ Eye Contact

Flush eyes with water as a precaution for at least 15 minutes.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do Not Induce Vomiting! Never give anything by mouth to an unconscious person. If conscious, wash out mouth with water. Get medical attention if necessary.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention if necessary.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Clear, colorless liquid
๐ŸŽจ Colour
colorless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
Not Flammable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1.1500 (water = 1)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not Flammable
๐Ÿ“Š Upper Explosive Limit
Not Explosive
๐Ÿ“Š Lower Explosive Limit
Not Explosive
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Completely soluble in water.
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Completely soluble in water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide local exhaust, preferably mechanical.

๐Ÿงค Hand Protection

Wear nitrile or rubber gloves

๐Ÿ‘๏ธ Eye Protection

Wear chemical safety glasses or goggles.

๐Ÿ˜ท Respiratory Protection

If exposure levels are excessive, use an approved respirator.

๐Ÿฆบ Skin/Body Protection

Wear apron or lab coat. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for L-Lysine 50%, Solution?

The signal word for this substance is "no signal word".

What is the physical form of L-Lysine 50%, Solution?

L-Lysine 50%, Solution is a liquid appearing as clear, colorless liquid with colorless color.

What is the solubility of L-Lysine 50%, Solution?

Completely soluble in water.

What is L-Lysine 50%, Solution used for?

Industrial, Manufacturing or Laboratory use