Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PREGAN MegaClean X-Tra
- Product Code
- 24416
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Post-treatment of screen printing mesh
Manufacturers & Suppliers
Kissel + Wolf GmbH
manufacturer
In den Ziegelwiesen 6, 69168 Wiesloch, Deutschland
+4962225780
Emergency Contacts
Emergency Contact
0049-6222-578-219
08:00-16:00 CET
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
GHS05
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of components, as listed below, with nonhazardous constituents
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| sodium hydroxide EC: 215-185-5 | 1310-73-2 | 12.5 - 15% | Yes |
| 2-Pyrrolidone EC: 210-483-1 | 616-45-5 | 8 - 10% | Yes |
| 2-(2-butoxyethoxy)ethanol EC: 203-961-6 | 112-34-5 | 7 - 8% | Yes |
| alcohols, C16-18, ethoxylated EC: 500-212-8 | 68439-49-6 | 7 - 8% | Yes |
| Isononanol, ethoxylated, propoxylated, carboxymethylated EC: 931-963-3 | 125304-09-8 | 5 - 7% | Yes |
| potassium hydroxide EC: 215-181-3 | 1310-58-3 | 3 - 5% | Yes |
| reaction mass of: N,N'-Ethane-1,2-diylbis(decanamide), 12-Hydroxy-N-[2-[1-oxydecyl)amino]ethyl]octadecanamide, N,N'-Ethane-1,2-diylbis(12-hydroxyoctadecanamide) | --- | 1 - 2% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest. In case of irregular breathing or respiratory arrest provide artificial respiration.
Remove contaminated, saturated clothing immediately. After contact with skin, wash immediately with plenty of water and soap. Immediate medical treatment required because corrosive injuries that are not treated are hard to cure.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical advice immediately.
If swallowed, rinse mouth with water (only if the person is conscious). Seek medical advice immediately. Keep victim calm. Do NOT induce vomiting.
Immediate Medical Attention
In all cases of doubt, or when symptoms persist, seek medical advice. Immediate medical treatment required because corrosive injuries that are not treated are hard to cure. Seek medical advice immediately. First Aid, decontamination, treatment of symptoms.
Medical Treatment
First Aid, decontamination, treatment of symptoms.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide good ventilation.This can be achieved with local or room suction.
Suitable material: CR (polychloroprene, chloroprene rubber) Thickness of the glove material: >= 0,5 mm Breakthrough time:: >= 480 min For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Observe the instructions and details for use, storage, maintenance and replacement provided by the protective glove manufacturer. Penetration time of glove material depending on intensity and duration of exposure to skin. Recommended glove articles:EN ISO 374
Eye glasses with side protection
Respiratory protection necessary at: spray application Suitable respiratory protection apparatus: Combination filtering device ABEK-P2
Barrier creams can help protecting exposed skin areas. In no case should they be used after contact. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.
Do not allow to enter into surface water or drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 1719
- Shipping Name
- Caustic alkali liquid, n.o.s.
- Transport Class
- 8
- Packing Group
- II
Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8
Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8
Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PREGAN MegaClean X-Tra?
The signal word is danger.
What is the physical form of PREGAN MegaClean X-Tra?
PREGAN MegaClean X-Tra is a liquid with brown color. It has characteristic odor.
What is PREGAN MegaClean X-Tra used for?
Post-treatment of screen printing mesh
What are the hazard statements for PREGAN MegaClean X-Tra?
This substance has 3 hazard statements:
- H314: Causes severe skin burns and eye damage.
- H317: May cause an allergic skin reaction.
- H360: May damage fertility or the unborn child.
What is the melting point of PREGAN MegaClean X-Tra?
The melting point is not determined and the boiling point is not determined.