Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Lead Free Flux Remover
- Product Code
- LFFR-a, ELFFR400DB, ZE
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Cleaning agent.
Uses advised against
No specific uses advised against are identified.
Manufacturers & Suppliers
ELECTROLUBE. A division of HK WENTWORTH LTD
manufacturer
ASHBY PARK, COALFIELD WAY, ASHBY DE LA ZOUCH, LEICESTERSHIRE LE65 1JR, UNITED KINGDOM
+44 (0)1530 419600
Emergency Contacts
Carechem 24
+44 1865 407333
24hr
Beaumont Hospital
+353 (0)1 809 2166
8am-10pm, 7 days a week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Cyclohexane EC: 203-806-2 | 110-82-7 | 30 - 60% | Yes |
| Propan-2-ol EC: 200-661-7 | 67-63-0 | 10 - 30% | Yes |
| 1-Methoxy-2-propanol EC: 203-539-1 | 107-98-2 | 10 - 30% | Yes |
| Hydrocarbons, C7, n-alkanes, isoalkanes, cyclics EC: 927-510-4 | 64742-49-0 | 5 - 10% | Yes |
| n-Butyl acetate EC: 204-658-1 | 123-86-4 | 1 - 5% | Yes |
| Orange Terpenes | 8028-48-6 | 1 - 5% | Yes |
| Carbon Dioxide | 124-38-9 | 1 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove affected person from source of contamination. Move affected person to fresh air and keep warm and at rest in a position comfortable for breathing. Maintain an open airway. Loosen tight clothing such as collar, tie or belt. When breathing is difficult, properly trained personnel may assist affected person by administering oxygen. Place unconscious person on their side in the recovery position and ensure breathing can take place.
Symptoms: A single exposure may cause the following adverse effects: Headache. Nausea, vomiting. Central nervous system depression. Drowsiness, dizziness, disorientation, vertigo. Narcotic effect.
It is important to remove the substance from the skin immediately. In the event of any sensitisation symptoms developing, ensure further exposure is avoided. Remove contamination with soap and water or recognised skin cleansing agent. Get medical attention if symptoms are severe or persist after washing.
Symptoms: May cause skin sensitisation or allergic reactions in sensitive individuals. Redness. Irritating to skin.
Rinse immediately with plenty of water. Remove any contact lenses and open eyelids wide apart. Continue to rinse for at least 10 minutes.
Symptoms: Irritating to eyes.
Rinse mouth thoroughly with water. Remove any dentures. Give a few small glasses of water or milk to drink. Stop if the affected person feels sick as vomiting may be dangerous. Do not induce vomiting unless under the direction of medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. Move affected person to fresh air and keep warm and at rest in a position comfortable for breathing. Place unconscious person on their side in the recovery position and ensure breathing can take place. Maintain an open airway. Loosen tight clothing such as collar, tie or belt.
Symptoms: May cause sensitisation or allergic reactions in sensitive individuals. Due to the physical nature of this product, it is unlikely that ingestion will occur. Aspiration hazard if swallowed. Entry into the lungs following ingestion or vomiting may cause chemical pneumonitis.
Immediate Medical Attention
Get medical attention immediately. May cause sensitisation or allergic reactions in sensitive individuals.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The product is flammable. Extinguish with alcohol-resistant foam, carbon dioxide, dry powder or water fog. Use fire-extinguishing media suitable for the surrounding fire.
Do not use water jet as an extinguisher, as this will spread the fire.
Containers can burst violently or explode when heated, due to excessive pressure build-up. Bursting aerosol containers may be propelled from a fire at high speed. If aerosol cans are ruptured, care should be taken due to the rapid escape of the pressurised contents and propellant. Vapours may form explosive mixtures with air.
Avoid breathing fire gases or vapours. Evacuate area. Keep upwind to avoid inhalation of gases, vapours, fumes and smoke. Ventilate closed spaces before entering them. Cool containers exposed to heat with water spray and remove them from the fire area if it can be done without risk. Cool containers exposed to flames with water until well after the fire is out. If a leak or spill has not ignited, use water spray to disperse vapours and protect men stopping the leak.
Firefighter Protection
Wear positive-pressure self-contained breathing apparatus (SCBA) and appropriate protective clothing. Firefighter's clothing conforming to European standard EN469 (including helmets, protective boots and gloves) will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken without appropriate training or involving any personal risk. Keep unnecessary and unprotected personnel away from the spillage. Do not touch or walk into spilled material. Evacuate area. Promptly remove any clothing that becomes contaminated. Avoid contact with skin and eyes.
Wipe up with an absorbent cloth and dispose of waste safely.
Inform the relevant authorities if environmental pollution occurs (sewers, waterways, soil or air).
Avoid discharge into drains or watercourses or onto the ground. Avoid discharge to the aquatic environment.
Wipe up with an absorbent cloth and dispose of waste safely. If the product is soluble in water, dilute the spillage with water and mop it up. Alternatively, or if it is not water-soluble, absorb the spillage with an inert, dry material and place it in a suitable waste disposal container. Flush contaminated area with plenty of water.
Materials: absorbent cloth, inert, dry material, water
Related Products
Similar products with comparable safety profiles
NO CLEAN SOLDER FLUXES
---
RS Pro Rework Solder Flux
UFI: UE80-G098-500F-77DH
LOCTITE 450-01 RWF 37K known as 450-01 REWORK FLUX
---
CW8400 Circuit-Works® Lead-Free Flux Dispensing Pen (UFI)
UFI: 9FC8-D0P6-5009-UE3N
Worthington Silver Brazing Flux
---
Loctite Super Bonder Remover
---
ES835BE Flux-Off®Rosin
---
Reflow Cleaner 94
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Read and follow manufacturer's recommendations. Wear protective clothing as described in Section 8 of this safety data sheet. Keep away from food, drink and animal feeding stuffs. Avoid exposing aerosol containers to high temperatures or direct sunlight. The product is flammable. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not handle until all safety precautions have been read and understood. Do not handle broken packages without protective equipment. Do not reuse empty containers. Do not spray on an open flame or other ignition source. Do not pierce or burn, even after use. Spray will evaporate and cool rapidly and may cause frostbite or cold burns if in contact with skin. Avoid contact with eyes. Avoid inhalation of vapours and spray/mists.
Keep container tightly closed, in a cool, well ventilated place. Keep containers upright. Protect containers from damage. Protect from sunlight. Do not store near heat sources or expose to high temperatures. Do not expose to temperatures exceeding 50°C/122°F.
Wash promptly if skin becomes contaminated. Take off contaminated clothing. Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product. Wash at the end of each work shift and before eating, smoking and using the toilet. Change work clothing daily before leaving workplace.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not spray on an open flame or other ignition source.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation. Personal, workplace environment or biological monitoring may be required to determine the effectiveness of the ventilation or other control measures and/or the necessity to use respiratory protective equipment. Use process enclosures, local exhaust ventilation or other engineering controls as the primary means to minimise worker exposure. Personal protective equipment should only be used if worker exposure cannot be controlled adequately by the engineering control measures. Ensure control measures are regularly inspected and maintained. Ensure operatives are trained to minimise exposure.
Chemical-resistant, impervious gloves complying with an approved standard should be worn if a risk assessment indicates skin contact is possible. The most suitable glove should be chosen in consultation with the glove supplier/manufacturer, who can provide information about the breakthrough time of the glove material. To protect hands from chemicals, gloves should comply with European Standard EN374. Considering the data specified by the glove manufacturer, check during use that the gloves are retaining their protective properties and change them as soon as any deterioration is detected. Frequent changes are recommended.
Eyewear complying with an approved standard should be worn if a risk assessment indicates eye contact is possible. Personal protective equipment for eye and face protection should comply with European Standard EN166. Wear tight-fitting, chemical splash goggles or face shield. If inhalation hazards exist, a full-face respirator may be required instead.
Respiratory protection complying with an approved standard should be worn if a risk assessment indicates inhalation of contaminants is possible. Ensure all respiratory protective equipment is suitable for its intended use and is CE-marked. Check that the respirator fits tightly and the filter is changed regularly. Gas and combination filter cartridges should comply with European Standard EN14387. Full face mask respirators with replaceable filter cartridges should comply with European Standard EN136. Half mask and quarter mask respirators with replaceable filter cartridges should comply with European Standard EN140.
Appropriate footwear and additional protective clothing complying with an approved standard should be worn if a risk assessment indicates skin contamination is possible.
Keep container tightly sealed when not in use. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
Very toxic to aquatic life with long lasting effects.
12.2. Persistence and degradability
The degradability of the product is not known.
12.3. Bioaccumulative potential
No data available on bioaccumulation or partition coefficient.
12.4. Mobility in soil
The product contains volatile organic compounds (VOCs) which will evaporate easily from all surfaces.
12.5. Results of PBT and vPvB assessment
12.6. Other adverse effects
None known.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
Always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
National regulations and EU legislation as listed.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Lead Free Flux Remover?
The signal word is danger.
What is the physical form of Lead Free Flux Remover?
Lead Free Flux Remover is a aerosol appearing as aerosol with colourless color. It has fruity odor.
What is Lead Free Flux Remover used for?
Cleaning agent.
What are the hazard statements for Lead Free Flux Remover?
This substance has 7 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: may burst if heated.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Lead Free Flux Remover?
The melting point is Not available and the boiling point is Not available.