NextSDS Logo
Safety Data Sheet EN

ES835BE Flux-Off®Rosin

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ES835BE Flux-Off®Rosin
Product Form
Aerosol
Product Code
ES835BE, ES1035E
Synonyms
Fluxing agents Remover

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Not applicable.

Uses advised against

Not applicable.

Manufacturers & Suppliers

C

Chemtronics

manufacturer

8125 Cobb Center Drive, Kennesaw, GA 30152

770-424-4888

I

ITW Contamination Control BV

importer

Saffierlaan 5, VZ-2132 Hoofddorp, The Netherlands

+31 88 1307 400

I

ITW Contamination Control BV

national supplier

Saffierlaan 5, VZ-2132 Hoofddorp, The Netherlands

+31 88 1307 400

C

Chemtronics

manufacturer

800-832-4401

C

Chemtronics

manufacturer

800-645-5244

C

Chemtrec

manufacturer

800-424-9300

Emergency Contacts

Chemtrec

1-800-424-9300

Chemtrec

703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurised container: May burst if heated.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P273 Avoid release to the environment.
P280 Wear protective gloves.
P282 Wear eye or face protection.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P312 Call a POISON CENTER or physician if you feel unwell.
P410 Protect from sunlight.
P412 Do not expose to temperatures exceeding 50 °C/122 °F.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2-methylpentane (containing < 5 % n-hexane (203-777-6)) EC: 203-523-4 107-83-5 25 - 50% Yes
3-methylpentane EC: 202-481-4 96-14-0 10 - 25% Yes
ethanol EC: 200-578-6 64-17-5 10 - 25% Yes
2,2-dimethylbutane EC: 200-906-8 75-83-2 10% Yes
2,3-dimethylbutane EC: 201-193-6 79-29-8 10% Yes
propan-2-ol EC: 200-661-7 67-63-0 10% Yes
n-hexane EC: 203-777-6 110-54-3 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention. If necessary, call a poison center or physician. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: respiratory tract irritation, coughing, nausea or vomiting, headache, drowsiness/fatigue, dizziness/vertigo, unconsciousness

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: irritation, redness

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: pain or irritation, watering, redness

Ingestion

Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention. If necessary, call a poison center or physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: Irritating to mouth, throat and stomach, stomach pains, nausea or vomiting

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

Extremely flammable aerosol. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Gas may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back, causing fire or explosion. Bursting aerosol containers may be propelled from a fire at high speed. Runoff to sewer may create fire or explosion hazard. This material is toxic to aquatic life with long lasting effects.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. In the case of aerosols being ruptured, care should be taken due to the rapid escape of the pressurised contents and propellant. If a large number of containers are ruptured, treat as a bulk material spillage according to the instructions in the clean-up section. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide adequate ventilation.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Collect spillage.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C. Do not pierce or burn, even after use. Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing gas. Avoid breathing vapour or mist. Avoid release to the environment. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Empty containers retain product residue and can be hazardous.

Storage

Pressurised container: protect from sunlight and do not expose to temperature exceeding 50°C.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Density
---
Decomposition Temperature
Not available.
Kinematic Viscosity
---
Colour Intensity
---
Appearance
---
Explosive Limits
---
Odor
Hydrocarbon. Characteristic. [Slight]
Boiling Point
Not available.
Partition Coefficient
Not available.
Odor Threshold
Not available.
Lower Explosive Limit
Not available.
Solubility
Not available.
Colour
Not available.
Auto Ignition Temperature
Not available.
Freezing Point
---
Physical State
Liquid. [Aerosol.]
Cloud Point
---
Properties Status
---
Upper Explosive Limit
Not available.
Metal Corrosion
---
State Under Standard Conditions
---
Vapor Density
Not available.
Voc Content
---
Solubility In Fat
---
Softening Point
---
Dynamic Viscosity
---
Solidification Point
---
Bulk Density
---
Flash Point
Closed cup: -29°C
Molecular Weight
---
Form
---
Crystallisation Point
---
Physical State Data
aerosol
Evaporation Rate
>1 (butyl acetate = 1)
Vapor Pressure
Not available.
Relative Evaporation Rate
---
Relative Density
Not available.
Solubility In Water
Not available.
Melting Point
Not available.
Ph
Not available.
Flammability
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame).

Incompatible

No specific data.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
Aerosols, flammable
Transport Class
2.1
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is ES835BE Flux-Off®Rosin known by?

ES835BE Flux-Off®Rosin is also known as: Fluxing agents Remover

What is the hazard signal word for ES835BE Flux-Off®Rosin?

The signal word is danger.

What is the physical form of ES835BE Flux-Off®Rosin?

ES835BE Flux-Off®Rosin is a liquid. [aerosol.] with not available. color. It has hydrocarbon. characteristic. [slight] odor.

What is the solubility of ES835BE Flux-Off®Rosin?

Not available.

What is ES835BE Flux-Off®Rosin used for?

Not applicable.

What are the hazard statements for ES835BE Flux-Off®Rosin?

This substance has 6 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of ES835BE Flux-Off®Rosin?

The melting point is Not available. and the boiling point is Not available..