NextSDS Logo
Safety Data Sheet EN

Carbo e-Therm ACR120-200A.01

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Carbo e-Therm ACR120-200A.01

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coatings.

Uses advised against

Any non-intended use.

Manufacturers & Suppliers

thermoheld GmbH logo

thermoheld GmbH

global supplier

Ritter-von-Eitzenberger-Str. 24 D-95448 Bayreuth

https://www.thermoheld.global/

Dr. Gans-Eichler Chemieberatung GmbH logo

Dr. Gans-Eichler Chemieberatung GmbH

undefined

Otto-Hahn-Str. 36 D-48161 Mnster

+49(0)2534 6441185

www.tge-consult.de

Emergency Contacts

Emergency Contact

+49 (0) 921 / 507 388 0

Mo-Fr 8:00-16:00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture
Chemical Name CAS Number Concentration Hazardous
diisobutyrate de 1-isopropyl-2,2-diméthyltriméthylène EC: 229-934-9 6846-50-0 1 - 3% Yes
Reaction mass of 2-methyl-2H-isothiazol-3-one and 5-chloro-2-methyl-2H-isothiazol-3-one 55965-84-9 0.1% Yes

Full text of H and EUH statements: see section 16.

Notes

Product does not contain listed SVHC substances > 0.1 % according to Regulation (EC) No. 1907/2006 Article 59 (REACH)

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of accident by inhalation: remove casualty to fresh air and keep at rest. In case of respiratory tract irritation, consult a physician.

Symptoms: In case of respiratory tract irritation, consult a physician.

Skin contact

After contact with skin, wash immediately with plenty of water and soap. In case of skin irritation, seek medical treatment.

Symptoms: In case of skin irritation, seek medical treatment.

Eye contact

Rinse immediately carefully and thoroughly with eye-bath or water. In case of troubles or persistent symptoms, consult an ophthalmologist.

Symptoms: In case of troubles or persistent symptoms, consult an ophthalmologist.

Ingestion

Rinse mouth thoroughly with water. Do NOT induce vomiting. Let water be drunken in little sips (dilution effect). In all cases of doubt, or when symptoms persist, seek medical advice.

Symptoms: In all cases of doubt, or when symptoms persist, seek medical advice.

Immediate Medical Attention

No information available.

Medical Treatment

No information available.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special measures are necessary.

Hands

In case of prolonged or frequently repeated skin contact: Wear protective gloves. DIN EN 374Suitable material:NBR (Nitrile rubber). (0,35 mm); Breakthrough time > 8 hCR (polychloroprenes, Chloroprene rubber). (0,5 mm); Breakthrough time > 8 hButyl rubber. (0,5 mm); Breakthrough time > 8 hFKM (fluororubber). (0,35 mm); Breakthrough time > 8 hFor special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.Before using check leak tightness / impermeability. In the case of wanting to use the gloves again, clean them before taking off and air them well.

Eyes

Wear safety glasses; chemical goggles (if splashing is possible).

Respiratory

With correct and proper use, and under normal conditions, breathing protection is not required.Respiratory protection necessary at: aerosol or mist generation.Suitable respiratory protective equipment: particulates filter device (DIN EN 143). Type: P1-3The filter class must be suitable for the maximum contaminant concentration (gas/vapour/aerosol/particulates)that may arise when handling the product. If the concentration is exceeded, closed-circuit breathing apparatus must be used!

Skin/Body

Protective clothing.Minimum standard for preventive measures while handling with working materials are specified in the TRGS 500 (D).

Environmental

Do not allow uncontrolled discharge of product into the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Relative Evaporation Rate
---
Upper Explosive Limit
not determined
Kinematic Viscosity
not determined
Softening Point
---
Explosive Limits
---
Auto Ignition Temperature
---
Vapor Pressure
~ 23 hPa
Ph
not determined
Colour
black
Metal Corrosion
---
Lower Explosive Limit
not determined
Odor
characteristic
Solubility In Water
not determined
Appearance
---
Evaporation Rate
---
Cloud Point
---
Partition Coefficient
---
Solubility
---
Boiling Point
~100 C
Form
---
Vapor Density
---
Bulk Density
---
Melting Point
not determined
Physical State Data
liquid
Properties Status
---
Colour Intensity
---
State Under Standard Conditions
---
Crystallisation Point
---
Freezing Point
---
Voc Content
---
Relative Density
---
Physical State
liquid
Decomposition Temperature
---
Solubility In Fat
---
Molecular Weight
---
Dynamic Viscosity
not determined
Density
not determined
Flash Point
>100 C
Odor Threshold
---
Flammability
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Carbo e-Therm ACR120-200A.01?

The signal word is no signal word.

What is the physical form of Carbo e-Therm ACR120-200A.01?

Carbo e-Therm ACR120-200A.01 is a liquid with black color. It has characteristic odor.

What is Carbo e-Therm ACR120-200A.01 used for?

Coatings.

What is the melting point of Carbo e-Therm ACR120-200A.01?

The melting point is not determined and the boiling point is ~100 C.

Compliance Scan