Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Turmotemp II/400 CL 2
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
LUBRICANT CONSULT GMBH
manufacturer
Gutenbergstraße 13, D-63477 Mainta 2
+49 6109/7650-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Hazard Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Combination of perfluoroethers, polytetrafluoroethylene (PTFE) and inorganic compounds.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| perfluoroethers | --- | --- | No |
| polytetrafluoroethylene (PTFE) | --- | --- | No |
| inorganic compounds | --- | --- | No |
Hazardous ingredients: None
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove the patient to fresh air. See a physician* if necessary.
Symptoms: cough, fever, shivers (from thermal decomposition vapours)
Wash with water and soap. Remove contaminated clothing. If grease has penetrated skin by force (in case of misuse of a grease press): See a physician* immediately.
Flush with plenty of water for at least 15 minutes. See a physician* if the eye irritation remains.
See a physician* if necessary. Do not induce vomiting.
Immediate Medical Attention
See a physician* immediately if grease has penetrated skin by force. See a physician* if necessary for other exposures.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
all (water, powder, foams, carbon dioxide)
Turmotemp II/400 CL 2 is not inflammable. But in the case of fire, the vapour can involve toxic and corrosive compounds (carbon monoxide, fluorine decomposition compounds).
Firefighter Protection
Use self-contained breathing apparatus and skin protection to protect from vapours.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Pick up free grease for recycle or disposal. Absorb small amounts on inert material. Collect the released product and the used absorbent materials in suitable containers for disposal (see sect. 13).
Absorb small amounts on inert material.
Avoid the uncontrolled discharge in sewage systems, in surface and underground waters.
Pick up free grease for recycle or disposal. Collect the released product and the used absorbent materials in suitable containers for disposal (see sect. 13).
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
In case of misuse of a grease press highly pressed lubricants can penetrate the skin and may be dangerous for the human health. Avoid the contact of other heat materials above 290°C (> 555°F).
Store in cool and dry areas.
Do not eat, drink and smoke in working areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Not necessary in normal use. When often handling the product wear rubber gloves
Not necessary in normal use. Wear safety glasses, if necessary.
Not necessary in normal use. Avoid breathing the vapours above the decomposition temperature.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is very stable in normal condition of use and storage.
temperatures above 290°C (555°F)
melted alkaline and earth-alkaline metals, metallic powders (Al, Zn) above 370°C (700°F)
HF and other vapours, which are toxic and corrosive
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Send the waste product to authorised plants according to local laws and regulations or destroy it using high-temperature incinerator designed to burn fluorine compounds.
Send the waste product to authorised plants according to local laws and regulations or destroy it using high-temperature incinerator designed to burn fluorine compounds.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- not assigned
- Packing Group
- not assigned
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No regulation and classification according to EEC directives necessary. No labelling with hazard symbols.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Turmotemp II/400 CL 2?
The signal word is no signal word.
What is the physical form of Turmotemp II/400 CL 2?
Turmotemp II/400 CL 2 is a pasty with white color.
What are the hazard statements for Turmotemp II/400 CL 2?
This substance has 2 hazard statements:
- The product when properly handled is not dangerous for the human health.
- Harmful effects are expected only in case of misuse especially in case of thermal decomposition.