NextSDS Logo
Safety Data Sheet EN

Hydrotherm 46 M A 8480206 RT

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Hydrotherm 46 M A 8480206 RT
Product Form
An aqueous solution
Product Code
311062
Chemical Name
An aqueous solution of polyglycol, di/tri-ethylene glycols, dimethyl ethanolamine and inhibitors

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industry sector : Metal Working Industry Type of use : Hydraulic fluids

Manufacturers & Suppliers

C

Clariant Produkte (Deutschland) GmbH

65926 Frankfurt am Main

+49 69 305 18000

Emergency Contacts

Emergency Contact

00800-5121 5121

24 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Diethylene glycol EC: 203-872-2 111-46-6 10 - 20% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. Get medical advice/ attention.

Skin contact

In case of contact, immediately flush skin with soap and plenty of water.

Eye contact

In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

Ingestion

If swallowed do not induce vomiting, seek medical advice and show safety datasheet or label

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray jet Alcohol-resistant foam Dry powder Carbon dioxide (CO2)

Unsuitable media

High volume water jet

Specific hazards

In case of fires, hazardous combustion gases are formed: Carbon monoxide (CO) Carbon dioxide (CO2) Nitrogen oxides (NOx)

Firefighter Protection

Wear suitable protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear suitable protective equipment. Ensure adequate ventilation.

Environmental

The product should not be allowed to enter drains, water courses or the soil.

Cleanup methods

Soak up with inert absorbent material

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

When used and handled appropriately no special measures are needed

Storage

Keep containers tightly closed in a cool, well-ventilated place. Handle and open container with care.

Hygiene

Wash hands before breaks and at the end of workday. Use protective skin cream before handling the product. Take off immediately all contaminated clothing and wash it before reuse.

Fire prevention

Observe the general rules of industrial fire protection

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Break through time : 480 min, Glove thickness : 0,7 mm, Remarks : Long-term exposure Impervious butyl rubber gloves. Break through time : 30 min, Glove thickness : 0,4 mm, Remarks : For short-term exposure (splash protection): Nitrile rubber gloves. Remarks : These types of protective gloves are offered by various manufacturers. Please note the manufacturers' detailed statements, especially about the minimum thickness and the minimum breakthrough time. Consider also the particular working conditions under which the gloves are being used.

Eyes

Depending on the risk, wear sufficient eye protection (safety glasses with side protection or goggles, and if necessary, face shield.)

Respiratory

Use only in well-ventilated areas. In the case of vapour formation use a respirator with an approved filter. Equipment should conform to EN 14387 If the occupational exposure limits cannot be met, in exceptional cases suitable respiratory equipment should be worn only for a short period of time. Filter type : Organic vapour type (A)

Skin/Body

Wear suitable protective equipment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solution
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
yellow-brown
Colour Intensity
---
Form
---
Odor
amine-like
Odor Threshold
not determined
Ph
9 - 11
Melting Point
---
Boiling Point
ca. 106 °C
Flash Point
ca. 260 °C
Freezing Point
---
Softening Point
---
Solidification Point
< -30 °C
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
not determined
Vapor Pressure
not tested.
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
ca. 1,08 g/cm3 (15 °C)
Flammability
---
Upper Explosive Limit
Not applicable
Lower Explosive Limit
Not applicable
Explosive Limits
---
Auto Ignition Temperature
(for a component of this mixture) not determined
Decomposition Temperature
> 260 °C
Solubility
---
Partition Coefficient
Not applicable
Solubility In Water
completely miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
Not corrosive to metals
Dynamic Viscosity
ca. 43 mPa.s (40 °C)
Kinematic Viscosity
no data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

None known.

Incompatible

Strong acids and oxidizing agents

Decomposition

When handled and stored appropriately, no dangerous decomposition products are known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Hydrotherm 46 M A 8480206 RT?

The signal word is no signal word.

What is the physical form of Hydrotherm 46 M A 8480206 RT?

Hydrotherm 46 M A 8480206 RT is a solution with yellow-brown color. It has amine-like odor.

What is Hydrotherm 46 M A 8480206 RT used for?

Industry sector : Metal Working Industry Type of use : Hydraulic fluids

Compliance Scanner

Scan your compliance