NextSDS Logo
Safety Data Sheet EN

neodisher MediClean forte

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
neodisher MediClean forte

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Washing and cleaning products (including solvent based products)

Manufacturers & Suppliers

Chemische Fabrik Dr. Weigert GmbH & Co. KG logo

Chemische Fabrik Dr. Weigert GmbH & Co. KG

manufacturer

Mühlenhagen 85, D-20539 Hamburg

+49 40 789 60 0

http://www.drweigert.com

Emergency Contacts

GBK/ Infotrac

1 800 535 5053

GBK/ Infotrac

+1 352 323 3500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
fatty alcohols, alkoxylated 120313-48-6 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Ensure supply of fresh air. In the event of symptoms take medical treatment.

Skin contact

In case of contact with skin wash off with warm water. Consult a doctor if skin irritation persists.

Eye contact

Separate eyelids, wash the eyes thoroughly with water (15 min.). In case of irritation consult an oculist.

Ingestion

Rinse out mouth and give plenty of water to drink.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product itself is non-combustible; adapt fire extinguishing measures to surrounding areas.

Specific hazards

In case of combustion evolution of dangerous gases possible.

Firefighter Protection

In case of combustion use a suitable breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin, eyes and clothing.

Environmental

Do not allow to enter drains or waterways.

Cleanup methods

Clean contaminated floors and objects thoroughly, observing environmental regulations.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Store product in closed containers. Keep container tightly closed and dry.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Chemical resistant gloves. Permanent hand contact: neoprene (>= 0,65 mm, > 480 min), nitrile (>= 0,4 mm, > 480 min), butyl (>= 0,7 mm, > 480 min). Short-term hand contact: nitrile (>= 0,11 mm).

Eyes

Safety glasses with side protection shield

Respiratory

Not necessary, but do not inhale vapours. If workplace limits are exceeded, a respiratory protection approved for this particular job must be worn.

Skin/Body

Clothing as usual in the chemical industry.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Softening Point
---
Boiling Point
not determined
Odor Threshold
not determined
Melting Point
not determined
Explosive Limits
---
Relative Evaporation Rate
---
Flammability
not determined
Cloud Point
---
Colour Intensity
---
Bulk Density
---
Solubility
not determined
Lower Explosive Limit
not determined
Physical State
liquid
State Under Standard Conditions
---
Upper Explosive Limit
not determined
Kinematic Viscosity
---
Properties Status
---
Relative Density
---
Evaporation Rate
not determined
Crystallisation Point
---
Vapor Pressure
not determined
Density
1,07 g/cm³
Voc Content
---
Appearance
---
Form
liquid
Flash Point
Not applicable
Dynamic Viscosity
< 10 mPa.s
Ph
appr. 10,1
Molecular Weight
---
Partition Coefficient
not determined
Vapor Density
not determined
Auto Ignition Temperature
not determined
Decomposition Temperature
not determined
Odor
characteristic
Colour
yellow to brownish
Solubility In Fat
---
Freezing Point
not determined
Solidification Point
---
Physical State Data
liquid
Metal Corrosion
---
Solubility In Water
miscible in all proportions
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No hazardous reactions known.

Reactivity

No hazardous reactions when stored and handled according to prescribed instructions.

Hazardous reactions

No hazardous reactions known.

Avoid

No hazardous reactions known.

Incompatible

None known

Decomposition

No hazardous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Allocation of a waste code number, according to the European Waste Catalogue (EWC), should be carried out in agreement with the regional waste disposal company.

Disposal

Allocation of a waste code number, according to the European Waste Catalogue (EWC), should be carried out in agreement with the regional waste disposal company.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

The product does not contain substances of very high concern (SVHC).

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for neodisher MediClean forte?

The signal word is no signal word.

What is the physical form of neodisher MediClean forte?

neodisher MediClean forte is a liquid with yellow to brownish color. It has characteristic odor.

What is the solubility of neodisher MediClean forte?

not determined

What is neodisher MediClean forte used for?

Washing and cleaning products (including solvent based products)

What is the melting point of neodisher MediClean forte?

The melting point is not determined and the boiling point is not determined.