NextSDS Logo
Safety Data Sheet EN

neodisher MediClean forte

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
neodisher MediClean forte

Regulatory Identifiers

CAS Number
N/A

Identified Uses

PC35 Washing and cleaning products (including solvent based products)

Manufacturers & Suppliers

Chemische Fabrik Dr. Weigert GmbH & Co. KG logo

Chemische Fabrik Dr. Weigert GmbH & Co. KG

manufacturer

Mühlenhagen 85, D-20539 Hamburg

+49 40 789 60 0

http://www.drweigert.com

Emergency Contacts

Emergency Contact

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
fatty alcohols, alkoxylated 120313-48-6 0.1 - 1% Yes
2,2',2''-nitrilotriethanol EC: 203-049-8 102-71-6 10 - 25% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Ensure supply of fresh air. In the event of symptoms take medical treatment.

Skin contact

In case of contact with skin wash off with warm water. Consult a doctor if skin irritation persists.

Eye contact

Separate eyelids, wash the eyes thoroughly with water (15 min.). In case of irritation consult an oculist.

Ingestion

Rinse out mouth and give plenty of water to drink.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product itself is non-combustible; adapt fire extinguishing measures to surrounding areas.

Specific hazards

In case of combustion evolution of dangerous gases possible.

Firefighter Protection

In case of combustion use a suitable breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin, eyes and clothing.

Environmental

Do not discharge into surface waters/groundwater.

Cleanup methods

Clean contaminated floors and objects thoroughly, observing environmental regulations.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Protect from heat and direct sunlight. Keep container tightly closed and dry. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Chemical resistant gloves Use: Permanent hand contact Appropriate Material: neoprene Material thickness: >= 0,65 mm Breakthrough time: > 480 min Appropriate Material: nitrile Material thickness: >= 0,4 mm Breakthrough time: > 480 min Appropriate Material: butyl Material thickness: >= 0,7 mm Breakthrough time: > 480 min Use: Short-term hand contact Appropriate Material: nitrile Material thickness: >= 0,11 mm Hand protection must comply with EN ISO 374.

Eyes

Safety glasses with side protection shield; Eye protection must comply with EN 166.

Respiratory

Not necessary, but do not inhale vapours. If workplace limits are exceeded, a respiratory protection approved for this particular job must be worn. Particle filter P2

Skin/Body

Not necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
yellowish to brownish, clear
Colour Intensity
---
Form
---
Odor
characteristic
Odor Threshold
not determined
Ph
appr. 10,1 (20 °C)
Melting Point
Remarks not determined
Boiling Point
Remarks not determined
Flash Point
Remarks Not applicable
Freezing Point
Remarks not determined
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
not determined
Vapor Pressure
Remarks not determined
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,07 g/cm³ (20 °C)
Flammability
evaluation Not applicable
Upper Explosive Limit
Remarks Not applicable
Lower Explosive Limit
Remarks Not applicable
Explosive Limits
---
Auto Ignition Temperature
Remarks Not applicable
Decomposition Temperature
Remarks Remarks not determined
Solubility
Remarks not determined
Partition Coefficient
Remarks not determined
Solubility In Water
miscible in all proportions
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
< 10 mPa.s (20 °C)
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No hazardous reactions known.

Reactivity

No hazardous reactions when stored and handled according to prescribed instructions.

Hazardous reactions

No hazardous reactions known.

Avoid

No hazardous reactions known.

Incompatible

None known

Decomposition

No hazardous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for neodisher MediClean forte?

The signal word is no signal word.

What is the physical form of neodisher MediClean forte?

neodisher MediClean forte is a liquid with yellowish to brownish, clear color. It has characteristic odor.

What is the solubility of neodisher MediClean forte?

Remarks not determined

What is neodisher MediClean forte used for?

PC35 Washing and cleaning products (including solvent based products)

What is the melting point of neodisher MediClean forte?

The melting point is Remarks not determined and the boiling point is Remarks not determined.