NextSDS Logo
Safety Data Sheet EN

Salmonella Latex Test

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Salmonella Latex Test
Product Code
FT0203

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Uses advised against

No Information available

Manufacturers & Suppliers

R

REMEL (EUROPE) LIMITED

manufacturer

Remel House, Clipper Boulevard West, Crossways, Dartford, Kent. DA2 6PT, UK

(+44) 1322 295600

O

Oxoid Ltd.

Wade Road, Basingstoke, Hants, UK, RG24 8PW

+44 (0) 1256 841144

Emergency Contacts

Carechem 24

+44 (0) 1865 407333

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Sodium azide EC: 247-852-1 26628-22-8 0.1% Yes
Formaldehyde EC: 200-001-8 50-00-0 0.09% Yes

Notes

For the full text of the R-phrases and H-Statements mentioned in this Section, see Section 16

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If breathing is difficult, give oxygen. Obtain medical attention.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Obtain medical attention.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Obtain medical attention.

Ingestion

Clean mouth with water and drink afterwards plenty of water.

Medical Treatment

Treat symptomatically

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Unsuitable media

No information available.

Specific hazards

Thermal decomposition can lead to release of irritating gases and vapors

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Use personal protective equipment.

Environmental

Should not be released into the environment.

Cleanup methods

Soak up with inert absorbent material. Keep in suitable, closed containers for disposal.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment. Ensure adequate ventilation. Avoid ingestion and inhalation. Do not get in eyes, on skin, or on clothing.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

None under normal use conditions..

Hands

Protective gloves. Glove materials: Natural rubber, Nitrile rubber, Neoprene, PVC. Standard: EN 374. Breakthrough time: See manufacturers recommendations.

Eyes

Safety glasses with side-shields (European standard - EN 166)

Respiratory

No protective equipment is needed under normal use conditions. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particle filter. Small scale/Laboratory use: Maintain adequate ventilation. Recommended half mask: Particle filtering: EN149:2001

Skin/Body

Long sleeved clothing

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colorless
Colour
Colorless
Colour Intensity
---
Form
---
Odor
No information available
Odor Threshold
No data available
Ph
Not applicable
Melting Point
No data available
Boiling Point
Not applicable
Flash Point
Not applicable
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
No data available
Relative Density
No data available
Bulk Density
Not applicable
Density
No data available
Flammability
Not applicable
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
No information available.
Partition Coefficient
Component Formaldehyde log Pow -0.35
Solubility In Water
No information available.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known, based on information available.

Hazardous reactions

Hazardous polymerization does not occur. None under normal processing.

Avoid

Incompatible products, Excess heat.

Incompatible

None known

Decomposition

None under normal use conditions

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with local regulations.

Disposal

Dispose of in accordance with local regulations.

Waste Codes

Waste Codes are not product specific, but application specific EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment/Reports (CSA/CSR) are not required for mixtures

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Salmonella Latex Test?

The signal word is no signal word.

What is the physical form of Salmonella Latex Test?

Salmonella Latex Test is a liquid. appearing as colorless with colorless color. It has no information available odor.

What is the solubility of Salmonella Latex Test?

No information available.

What is Salmonella Latex Test used for?

Laboratory chemicals

What is the melting point of Salmonella Latex Test?

The melting point is No data available and the boiling point is Not applicable.