NextSDS Logo
Safety Data Sheet EN

LubriFluid F100

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LubriFluid F100

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Universal lubricant for minimal-quantity lubrication purposes

Manufacturers & Suppliers

S

SKF Lubrication Systems Germany AG

manufacturer

Motzenerstr. 35/37, 12277 Berlin, Germany

49 (0) 30 72002-0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Modified fatty media

Void

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Get fresh air, see a doctor in the event of complaints.

Skin contact

Wash off with large quantities of water and soap.

Eye contact

Hold lids open and rinse out eyes for several minutes with flowing water.

Ingestion

Consult a doctor if complaints persist.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO₂, extinguishing powder or sand. Fight large fires with jets of water spray, take extinguishing measures that suit the respective environment.

Unsuitable media

Full water jet

Specific hazards

Carbon monoxide (CO)

Firefighter Protection

When extinguishing: put on breathing apparatus that does not depend on the ambient air.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow substance to get into the sewage system or open waters. Prevent spreading (e.g. by damming up or by oil booms). Do not let substance get into the soil/subsoil.

Cleanup methods

Mop up with liquid-binding material (sand, kieselgur, acid binders, universal binders, sawdust).

Materials: sand, kieselgur, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace.

Storage

Observe all storage regulations. Protect from frost and direct sun light. Original containers to be kept dry and firmly closed.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Protective gloves and protective skin cream. Material of gloves: Nitrile rubber, NBR. Penetration time of glove material: Nitrile: thrick 0,4 mm, break trough time > 240 min. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Not required.

Respiratory

Not necessary if room is well-ventilated.

Skin/Body

Protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
---
Solidification Point
---
Ph
---
Cloud Point
---
Density
0.842 g/ccm
Crystallisation Point
---
Molecular Weight
---
Vapor Density
---
Softening Point
---
Decomposition Temperature
---
Odor Threshold
---
Voc Content
---
Solubility In Fat
---
Physical State
liquid
Solubility In Water
not miscible or only to slight extent
Lower Explosive Limit
---
Explosive Limits
---
Kinematic Viscosity
25 mm²/s
Colour
light
Odor
characteristic
Dynamic Viscosity
---
Metal Corrosion
---
Colour Intensity
---
Upper Explosive Limit
---
Form
liquid
Appearance
---
Auto Ignition Temperature
---
Evaporation Rate
---
Partition Coefficient
---
Relative Evaporation Rate
---
Properties Status
---
Physical State Data
liquid
Relative Density
---
Freezing Point
-9C
Boiling Point
not determined.
Flash Point
184 °C
State Under Standard Conditions
---
Solubility
not miscible or only to slight extent
Melting Point
not determined.
Bulk Density
---
Flammability
not spontaneously combustible
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

No hazardous reactions known.

Avoid

No decomposition if used as intended.

Incompatible

Strong oxidants.

Decomposition

No hazardous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Must not be disposed of together with household garbage. Disposal must be made according to official regulations.

Waste Codes

12 01 07 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product has not been classified and marked in accordance with EU Directives / respective national laws. Observe the general safety regulations when handling chemicals

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LubriFluid F100?

The signal word is no signal word.

What is the physical form of LubriFluid F100?

LubriFluid F100 is a liquid with light color. It has characteristic odor.

What is the solubility of LubriFluid F100?

not miscible or only to slight extent

What is LubriFluid F100 used for?

Universal lubricant for minimal-quantity lubrication purposes

What is the melting point of LubriFluid F100?