Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Lubrifluid
- Product Code
- 1600064
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Auxiliary for dental technology Lubricant
Manufacturers & Suppliers
Bien Air USA, Inc.
manufacturer
5 Corporate Park Suite 160 IRVINE, CA 92606 USA
(800)-433-2436, (949)-477-6050
Product Safety Department
Emergency Contacts
Emergency Contact
1-800-424-9300
Emergency Contact
+1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS04
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Active substance with propellant
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C6, isoalkanes, <5% n-hexane | 64742-49-0 | 10 - 20% | Yes |
| Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, < 5% n-hexane | 64742-49-0 | 10 - 20% | Yes |
| Hydrocarbons, C7-C9, n-alkanes, isoalkanes, cyclics | 64742-49-0 | 10 - 20% | Yes |
| carbon dioxide | 124-38-9 | 1 - 10% | Yes |
| Hydrogenated dimerization products of 1-decene and Reaction products of 1-decene, hydrogenated | --- | 1 - 1.5% | Yes |
| isobutane | 75-28-5 | 20 - 30% | Yes |
| propane | 74-98-6 | 10 - 20% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Keep ignition sources away - Do not smoke. Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C, i.e. electric lights. Do not pierce or burn, even after use. Do not spray on a naked flame or any incandescent material.
Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50°C.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
Not necessary if room is well-ventilated. Use suitable respiratory protective device when high concentrations are present. Filter AX
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No further relevant information available.
Reacts violently with oxidizing agents.
No decomposition if used and stored according to specifications.
No further relevant information available.
Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- Aerosols
- Transport Class
- 2.1
- Packing Group
- Void
Warning: Gases
Warning: Gases
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Lubrifluid?
The signal word is danger.
What is the physical form of Lubrifluid?
Lubrifluid is a aerosol appearing as colorless with colorless color. It has characteristic odor.
What is Lubrifluid used for?
Auxiliary for dental technology Lubricant
What are the hazard statements for Lubrifluid?
This substance has 3 hazard statements:
- H222: Extremely flammable aerosol.
- H280: Contains gas under pressure; may explode if heated.
- H304: May be fatal if swallowed and enters airways.
What is the melting point of Lubrifluid?