01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Interflon Food Lube G100

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricant

Manufacturers & Suppliers

Interflon b.v. logo

Interflon b.v.

manufacturer

P.O. Box 1070, NL-4700 BB Roosendaal, The Netherlands

+31(0)165.55.39.11

http://www.interflon.com

Emergency Contacts

Emergency Contact

+31 (0)165 55 39 11

Monday to Friday from 8:30am to 17:00pm

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Blend of mineral and synthetic oils, additives and Teflon®.

For the wording of the listed hazard phrases refer to section 16. This product does not contain "very worrisome substances" (SVHC) that are very dangerous to human health or the environment. (SVHC < 0.1% (w/w) Regulation (EC) No. 1907/2006 (REACH), Article 57).

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions. CO2, sand, extinguishing powder. Foam.

Unsuitable media

Water

Specific hazards

Formation of toxic gases is possible during heating or in case of fire.

Firefighter Protection

Wear self-contained respiratory protective device. Use personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Particular danger of slipping on leaked/spilled product.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures required.

Storage

No special requirements.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

No chemical-protective gloves required. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Not required. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Practical experience has shown that gloves of neoprene, Nitril and PVC offer sufficient protection. Breakthrough time: < 60 minutes.

Eyes

Goggles (EN166) recommended during refilling

Respiratory

Not required.

Skin/Body

Protective work clothing (EN340)

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Cloud Point
---
Appearance
Form: Fluid, Colour: Cloudy
Decomposition Temperature
Not determined.
Kinematic Viscosity
100 mm²/s
Relative Density
Not determined.
Physical State
Fluid
Colour Intensity
---
Melting Point
Not applicable.
Solidification Point
---
Partition Coefficient
---
Voc Content
---
Ph
Not applicable.
Properties Status
---
Relative Evaporation Rate
---
Vapor Pressure
Not determined.
Auto Ignition Temperature
Not determined.
Crystallisation Point
---
Odor
Nearly odourless
Form
Fluid
Density
0.87 g/cm³
Colour
Cloudy
Vapor Density
Not determined.
Softening Point
---
Upper Explosive Limit
Not determined.
Evaporation Rate
Not determined.
Odor Threshold
Not determined.
Solubility
---
Bulk Density
---
Dynamic Viscosity
320 mPas
Lower Explosive Limit
Not determined.
Flammability
Not applicable.
Solubility In Fat
---
Freezing Point
---
Flash Point
210 °C
Explosive Limits
---
Solubility In Water
Not miscible or difficult to mix.
Molecular Weight
---
Physical State Data
liquid
Metal Corrosion
---
State Under Standard Conditions
---
Boiling Point
>380 °C
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

To avoid thermal decomposition do not overheat.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

Strong oxidising agents.

Decomposition

Carbon monoxide and partially combusted carbohydrates can be released during thermal decomposition. Fluoride compounds can be released from 400°C.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Disposal

Must not be disposed together with household garbage.

Waste Codes

13 02 08* other engine, gear and lubricating oils EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not classified
Packing Group
Not classified
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Interflon Food Lube G100?

The signal word is no signal word.

What is the physical form of Interflon Food Lube G100?

Interflon Food Lube G100 is a fluid appearing as form: fluid, colour: cloudy with cloudy color. It has nearly odourless odor.

What is Interflon Food Lube G100 used for?

Lubricant

What is the melting point of Interflon Food Lube G100?

The melting point is Not applicable. and the boiling point is >380 °C.