Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Colloidion 4%
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals, Industrial & for professional use only.
Manufacturers & Suppliers
Central Drug House (P) Ltd
manufacturer
7/28 Vardaan House, New Delhi-10002, INDIA
Emergency Contacts
Emergency Contact
+91 11 49404040
9:00am - 6:00 pm
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
Wash off with soap and plenty of water. Consult a physician.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Carbon oxides, Nitrogen oxides (NOx)
Wear self-contained breathing apparatus for firefighting if necessary.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate personnel to safe areas.
Prevent further leakage or spillage if safe to do so.
collect with an electrically protected vacuum cleaner or by wet-brushing
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Avoid inhalation of vapour or mist. Keep away from sources of ignition - No smoking. Take measures to prevent the build up of electrostatic charge.
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Keep away from sources of ignition - No smoking. Take measures to prevent the build up of electrostatic charge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle in accordance with good industrial hygiene and safety practice.
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Where risk assessment shows air-purifying respirators are appropriate. Use a full-face respirator with multi-purpose combination (US) or type AXBEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Impervious clothing, Flame retardant antistatic protective clothing., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Prevent further leakage or spillage if safe to do so. Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No data available
No data available
Heat, flames and sparks. Test for peroxide formation periodically and before distillation. Extremes of temperature and direct sunlight. Heat, flames and sparks.
Oxidizing agents, Alkali metals
Other decomposition products - No data available. In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal company.
Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as this material is highly flammable. Offer surplus and non-recyclable solutions to a licensed disposal company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1993
- Shipping Name
- FLAMMABLE LIQUID, N.O.S. (Diethyl ether)
- Transport Class
- 3
- Packing Group
- I
No data available
No data available
No data available
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This safety datasheet complies with the requirements of Regulation (EC) No.453/2010.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Colloidion 4%?
The signal word is danger.
What is the physical form of Colloidion 4%?
Colloidion 4% is a liquid appearing as liquid . It has no data available odor.
What is the solubility of Colloidion 4%?
insoluble
What is Colloidion 4% used for?
Laboratory chemicals, Industrial & for professional use only.
What are the hazard statements for Colloidion 4%?
This substance has 2 hazard statements:
- H224: Extremely flammable liquid and vapour.
- H336: May cause drowsiness or dizziness.
What is the melting point of Colloidion 4%?
The melting point is No data available and the boiling point is 34 °C.