NextSDS Logo
Safety Data Sheet EN

Aquagent®, standard solution 0,1%

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Aquagent®, standard solution 0,1%
Product Code
AQ0019

Regulatory Identifiers

CAS Number
N/A
UFI Code
VPC0-R05P-K000-S2R8

Identified Uses

Laboratory reagent

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

Scharlab, S.L. logo

Scharlab, S.L.

manufacturer

C/Gato Pérez, 33. Pol.Ind. Mas d'en Cisa, 08181 Sentmenat (Barcelona) SPAIN

(+34) 93 745 64 00

http://www.scharlab.com

Scharlab, S.L. logo

Scharlab, S.L.

distributor

C/Gato Pérez, 33. Pol.Ind. Mas d'en Cisa, 08181 Sentmenat (Barcelona) SPAIN

(+34) 93 745 64 00

http://www.scharlab.com

Emergency Contacts

Toxicological Information National Institute of Toxicology and Forensic Sciences

+34 91 562 04 20

24h/365 days

Scharlab, S.L.

(+34) 93 715 18 11

During normal opening times

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H226 Flammable liquid and vapour.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P241 Use explosion-proof [electrical/ventilating/lighting] equipment.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P370+P378 In case of fire: Use CO2, powder or water spray to extinguish.
P403+P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents/container in accordance with local/regional/national/ international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
anisole EC: 202-876-1 100-66-3 50 - 100% Yes
propylene carbonate EC: 203-572-1 108-32-7 2 - 5% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Density
1.0245 g/cm
Dynamic Viscosity
Not determined.
Freezing Point
---
Decomposition Temperature
Not determined.
Physical State
Fluid
Vapor Pressure
0.4 hPa
Relative Evaporation Rate
---
Solubility In Water
34 g/l
Odor Threshold
Not determined.
Properties Status
---
Cloud Point
---
Upper Explosive Limit
Not determined.
Solidification Point
---
Evaporation Rate
Not determined.
State Under Standard Conditions
---
Solubility In Fat
---
Melting Point
-37 C
Form
Fluid
Colour Intensity
---
Appearance
Fluid
Auto Ignition Temperature
475 C
Boiling Point
Undetermined.
Voc Content
---
Explosive Limits
---
Solubility
---
Kinematic Viscosity
Not determined.
Odor
Characteristic
Flammability
Flammable.
Molecular Weight
108.14 g/mol
Flash Point
43 C
Colour
Colourless
Vapor Density
Not determined.
Physical State Data
liquid
Softening Point
---
Metal Corrosion
Void
Ph
Not determined.
Lower Explosive Limit
Not determined.
Partition Coefficient
Not determined.
Crystallisation Point
---
Bulk Density
---
Relative Density
Not determined.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN2222
Shipping Name
ANISOLE
Transport Class
3 Flammable liquids.
Packing Group
III
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Aquagent®, standard solution 0,1%?

The signal word is warning.

What is the physical form of Aquagent®, standard solution 0,1%?

Aquagent®, standard solution 0,1% is a fluid appearing as fluid with colourless color. It has characteristic odor.

What is Aquagent®, standard solution 0,1% used for?

Laboratory reagent

What are the hazard statements for Aquagent®, standard solution 0,1%?

This substance has 1 hazard statement:

  • H226: Flammable liquid and vapour.

What is the melting point of Aquagent®, standard solution 0,1%?

The melting point is -37 C and the boiling point is Undetermined..