Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ethanol 96 %, Ph.Eur., extra pure
- Product Code
- P075
- Chemical Name
- Ethanol
- Synonyms
- Ethyl alcohol
Regulatory Identifiers
- CAS Number
- 64-17-5 Check regulations →
- EC Number
- 200-578-6 Check regulations →
- REACH No.
- 01-2119457610-43-xxxx
Identified Uses
Laboratory and analytical use Laboratory chemical Industrial uses Professional uses
Uses advised against
Do not use for private purposes (household). Food, drink and animal feedingstuffs.
Manufacturers & Suppliers
Carl Roth GmbH + Co. KG
Schoemperlenstr. 3-5 D-76185 Karlsruhe Germany
+49 (0) 721 - 56 06 0
www.carlroth.de
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Ethanol 96 %, Ph.Eur., extra pure
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ethanol EC: 200-578-6 | 64-17-5 | 96% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Provide fresh air. In all cases of doubt, or when symptoms persist, seek medical advice.
Rinse skin with water/shower. In all cases of doubt, or when symptoms persist, seek medical advice.
Irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart. In case of eye irritation consult an ophthalmologist.
Rinse mouth. Call a doctor if you feel unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
co-ordinate firefighting measures to the fire surroundings! water spray, alcohol resistant foam, dry extinguishing powder, BC-powder, carbon dioxide (CO₂)
water jet
Combustible. In case of insufficient ventilation and/or in use, may form flammable/explosive vapourair mixture. Solvent vapours are heavier than air and may spread along floors. Places which are not ventilated, e.g. unventilated below ground level areas such as trenches, conduits and shafts, are particularly prone to the presence of flammable substances or mixtures. Vapours are heavier than air, spread along floors and form explosive mixtures with air. Vapours may form explosive mixtures with air.
In case of fire and/or explosion do not breathe fumes. Fight fire with normal precautions from a reasonable distance.
Firefighter Protection
In case of fire and/or explosion do not breathe fumes. Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with skin, eyes and clothes. Do not breathe vapour/spray. Avoidance of ignition sources.
Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.
Absorb with liquid-binding material (sand, diatomaceous earth, acid- or universal binding agents). Place in appropriate containers for disposal. Ventilate affected area.
Materials: liquid-binding material (sand, diatomaceous earth, acid- or universal binding agents)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Provision of sufficient ventilation.
Store in a well-ventilated place. Keep container tightly closed. Protect from sunlight. Recommended storage temperature: 15 – 25 °C
Wash hands before breaks and after work. Keep away from food, drink and animal feedingstuffs. When using do not smoke.
Keep away from sources of ignition - No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. The times are approximate values from measurements at 22 ° C and permanent contact. Increased temperatures due to heated substances, body heat etc. and a reduction of the effective layer thickness by stretching can lead to a considerable reduction of the breakthrough time. If in doubt, contact manufacturer. At an approx. 1.5 times larger / smaller layer thickness, the respective breakthrough time is doubled / halved. The data apply only to the pure substance. When transferred to substance mixtures, they may only be considered as a guide. • type of material Butyl caoutchouc (butyl rubber) • material thickness 0,7 mm • breakthrough times of the glove material >480 minutes (permeation: level 6)
Use safety goggle with side protection.
Respiratory protection necessary at: Aerosol or mist formation. Type: A (against organic gases and vapours with a boiling point of > 65 °C , colour code: Brown).
Flame-retardant protective clothing.
Keep away from drains, surface and ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.
It's a reactive substance. Risk of ignition. Vapours may form explosive mixtures with air. If heated: Risk of ignition.
Violent reaction with: strong oxidiser, Alkali metals, Alkaline earth metal, Acetic anhydride, Peroxides, Phosphorus oxides (e.g. P2O5), Nitric acid, Nitrate, Perchlorates, => Explosive properties
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
There is no additional information.
Hazardous combustion products: see section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Waste shall be separated into the categories that can be handled separately by the local or national waste management facilities.
This material and its container must be disposed of as hazardous waste. Dispose of contents/container in accordance with local/regional/national/international regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 1170
- Shipping Name
- ETHANOL
- Transport Class
- 3
- Packing Group
- II
Provisions for dangerous goods (ADR) should be complied within the premises.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Ethanol 96 %, Ph.Eur., extra pure known by?
Ethanol 96 %, Ph.Eur., extra pure is also known as: Ethyl alcohol
What is the hazard signal word for Ethanol 96 %, Ph.Eur., extra pure?
The signal word is danger.
What is the physical form of Ethanol 96 %, Ph.Eur., extra pure?
Ethanol 96 %, Ph.Eur., extra pure is a liquid with colourless color. It has like: - alcohol odor.
What is the solubility of Ethanol 96 %, Ph.Eur., extra pure?
completely miscible with water
What is Ethanol 96 %, Ph.Eur., extra pure used for?
Laboratory and analytical use Laboratory chemical Industrial uses Professional uses
What are the hazard statements for Ethanol 96 %, Ph.Eur., extra pure?
This substance has 2 hazard statements:
- H225: Highly flammable liquid and vapour
- H319: Causes serious eye irritation
What is the melting point of Ethanol 96 %, Ph.Eur., extra pure?
The melting point is -114 °C and the boiling point is 78 °C at 1.013 hPa.