Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FLECAINIDE ACETATE CRS
- Product Code
- F0120000
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For laboratory tests and assays only, as described in the European Pharmacopoeia.
Manufacturers & Suppliers
European Directorate for the Quality of Medicines & HealthCare
7, Allée Kastner CS 30026, F-67081 Strasbourg (France)
+33 (0)3 88 41 20 35
http://www.edqm.eu
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Flecainide acetate EC: 258-997-5 | 54143-56-5 | --- | Yes |
Notes
NB: Sodium channel blocking agent, class I anti-arrhythmic agent.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If breathing becomes difficult, call a physician. If breathing stops, give oxygen.
Flush with copious amounts of water and soap for at least 15 minutes. Remove contaminated clothing and shoes.
Assure adequate flushing by separating the eyelids with fingers. Flush with copious amounts of water for at least 15 minutes.
Wash out mouth with water and administer fresh water provided that the person is conscious. Monitor breathing and pulse.
Immediate Medical Attention
In case of reactions described in hazards identification or other severe, immediate or persisting symptoms seek medical advice and call the nearest poison centre. Show the label and this safety data sheet.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide, dry chemical powder or appropriate foam. Water spray.
Emits toxic fumes under fire conditions. Risk of dust explosion cannot be excluded.
Firefighter Protection
Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and eyes.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Switch off electrical equipment and any other sources of ignition. Evacuate area. Wear self-contained breathing apparatus, appropriate boots and heavy rubber gloves. Collect residues manually, wipe with a small quantity of water, place in a bag and hold for waste disposal. Avoid raising dust/mist. Ventilate area and wash spill site with water after material pick up is complete.
Collect residues manually, wipe with a small quantity of water, place in a bag and hold for waste disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation. Avoid contact with eyes, skin and clothing. Avoid prolonged or repeated exposure. Avoid use with incompatible materials. Recommended for quality reasons: Handle protected from humidity.
Keep unopened and tightly closed in the original container protected from incompatible materials, heat, direct sunlight and sources of ignition. For quality reasons: keep protected from humidity at about 2-8 °C.
Keep protected from heat and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handling of small quantities in fume hood recommended. Mechanical exhaust, safety shower and eye bath required.
Compatible chemical-resistant gloves.
Wear protective chemical safety goggles.
Protecting mask (filter P2).
Wear protective coat.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended conditions of use.
Hazardous polymerisation will not occur.
Humidity. Light. Heat. Ignition.
Strong oxidizing agents.
COₓ, NOₓ, HF and other substances in case of incomplete decomposition.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.6 Endocrine disrupting properties
12.7 Other adverse effects
12.5 Results of PBT and vPvB assessment
12.1 Toxicity
Soluble in water.
12.2 Persistence and degradability
No data available
12.3 Bioaccumulative potential
No data available
12.4 Mobility in soil
No data available
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Incinerate in an approved facility.
Incinerate in an approved facility.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This substance is not listed in Annex I of Directive 67/548/EC. R phrases: R22 (Harmful if swallowed), R62 (Possible risk of impaired fertility), R63 (Possible risk of harm to the unborn child). S phrases: S22 (Do not breathe dust), S36/37 (Wear suitable protective clothing and gloves).
CMR Classification: R3
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for FLECAINIDE ACETATE CRS?
The signal word is no signal word.
What is the solubility of FLECAINIDE ACETATE CRS?
Soluble in water and in anhydrous ethanol. It is freely soluble in dilute acetic acid and practically insoluble in dilute hydrochloric acid.
What is FLECAINIDE ACETATE CRS used for?
For laboratory tests and assays only, as described in the European Pharmacopoeia.
What is the melting point of FLECAINIDE ACETATE CRS?
The melting point is 146 152C .