NextSDS Logo
Safety Data Sheet EN

KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE
Product Code
118377E

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Surface disinfectant. Manual process Biocide. Manual process

Uses advised against

Reserved for industrial and professional use.

Manufacturers & Suppliers

E

Ecolab Ltd.

manufacturer

PO Box 11; Winnington Avenue Northwich, Cheshire, United Kingdom CW8 4DX

+44 (0)1606 74488

Emergency Contacts

Emergency Contact

+441618841235

Trans-European

+32-(0)3-575-5555

Poison Information Centre

0344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation.

Precautionary Statements

P280 Wear eye protection/face protection.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrogen peroxide EC: 231-765-0 7722-84-1 5 - 8% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Get medical attention if symptoms occur.

Skin contact

Rinse with plenty of water.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

None known.

Specific hazards

Not flammable or combustible.

Instructions

In the event of fire and/or explosion do not breathe fumes.

Firefighter Protection

Use personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure clean-up is conducted by trained personnel only. Refer to protective measures listed in sections 7 and 8.

Large spill

dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.

Environmental

Do not allow contact with soil, surface or ground water.

Cleanup methods

collect with non-combustible absorbent material and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water.

Materials: non-combustible absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Use only with adequate ventilation. Wash hands thoroughly after handling. In case of mechanical malfunction, or if in contact with unknown dilution of product, wear full Personal Protective Equipment (PPE).

Storage

Keep out of reach of children. Keep container tightly closed. Store in suitable labeled containers. Do not hermetically seal the container. Risk of overpressure and bursting in the event of decomposition in closed containers and in pipes.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

In case of skin contact it is recommended to wear gloves to avoid oxidation effect (e.g. skin whitening)

Eyes

Safety glasses with side-shields

Respiratory

None required if airborne concentrations are maintained below the exposure limit listed in Exposure Limit Information. Use certified respiratory protection equipment meeting EU requirements(89/656/EEC, (EU) 2016/425), or equivalent, when respiratory risks cannot be avoided or sufficiently limited by technical means of collective protection or by measures, methods or procedures of work organization.

Skin/Body

No special protective equipment required.

Environmental

Consider the provision of containment around storage vessels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
colourless
Colour Intensity
---
Form
---
Odor
pungent
Odor Threshold
Not applicable and/or not determined for the mixture
Ph
3.5 - 6.5, 100 %
Melting Point
Not applicable and/or not determined for the mixture
Boiling Point
Not applicable and/or not determined for the mixture
Flash Point
Not applicable.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable and/or not determined for the mixture
Vapor Pressure
Not applicable and/or not determined for the mixture
Vapor Density
---
Relative Density
1.02 - 1.023
Bulk Density
---
Density
---
Flammability
Not applicable and/or not determined for the mixture
Upper Explosive Limit
Not applicable and/or not determined for the mixture
Lower Explosive Limit
Not applicable and/or not determined for the mixture
Explosive Limits
---
Auto Ignition Temperature
Not applicable and/or not determined for the mixture
Decomposition Temperature
Not applicable and/or not determined for the mixture
Solubility
---
Partition Coefficient
Not applicable and/or not determined for the mixture
Solubility In Water
soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Not applicable and/or not determined for the mixture
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Decomposes on heating. Contamination may result in dangerous pressure increases - closed containers may rupture.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

None known.

Incompatible

None known.

Decomposition

Not applicable.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Environmental Effects : This product has no known ecotoxicological effects. #### Product Toxicity to fish : no data available Toxicity to daphnia and other aquatic invertebrates : no data available Toxicity to algae : no data available #### Components

This product has no known ecotoxicological effects.

12.1 Toxicity

Toxicity to fish : Hydrogen peroxide96 h LC50 Pimephales promelas (fathead minnow): 16.4 mg/l

12.1 Toxicity

Toxicity to algae : Hydrogen peroxide 72 h EC50 Skeletonema costatum (marine diatom): 1.38 mg/l

12.2 Persistence and degradability

Product: no data available. Components: 118377E. Biodegradability: Hydrogen peroxide. Result: Not applicable - inorganic

12.3 Bioaccumulative potential

no data available

12.4 Mobility in soil

no data available

12.5 Results of PBT and vPvB assessment

no data available

12.6 Endocrine disrupting properties

no data available

12.7 Other adverse effects

no data available

12.3 Bioaccumulative potential

no data available

no data available

12.4 Mobility in soil

no data available

no data available

12.5 Results of PBT and vPvB assessment

This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

The product does not contain components considered to be PBT or vPvB at levels of 0.1% or higher.

12.6 Other adverse effects

no data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Where possible recycling is preferred to disposal or incineration. If recycling is not practicable, dispose of contents/container in accordance with local regulations. Dispose of wastes in an approved waste disposal facility.

Disposal

Dispose of wastes in an approved waste disposal facility.

Waste Codes

Not specified European Waste Catalogue Code EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE?

The signal word is warning.

What is the physical form of KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE?

KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE is a liquid appearing as liquid with colourless color. It has pungent odor.

What is KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE used for?

Surface disinfectant. Manual process Biocide. Manual process

What are the hazard statements for KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation.

What is the melting point of KLERCIDE SPORICIDAL LOW RESIDUE PEROXIDE?

The melting point is Not applicable and/or not determined for the mixture and the boiling point is Not applicable and/or not determined for the mixture.