NextSDS Logo
We

Weld Spray Perfect 400ml

DANGER Aerosol containing a liquefied gas SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Weld Spray Perfect 400ml
Product Code
0893102100

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
CNM2-H05M-G00N-W4MM

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Surface treatment, Preservative Professional use product
Uses Advised Against
Not applicable

Overview

Weld Spray Perfect 400ml is a aerosol containing a liquefied gas substance commonly used surface treatment, preservative professional use product.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H336: May cause drowsiness or dizziness.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P211: Do not spray on an open flame or other ignition source.
  • P251: Do not pierce or burn, even after use.
  • P261: Avoid breathing spray.
  • P410 + P412: Protect from sunlight. Do not expose to tem- peratures exceeding 50 / 122 F.
  • IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/ doctor if you feel unwell.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Wurth UK Ltd

distributor

πŸ“

1 Centurion Way Erith, Kent

🌍

GB

πŸ“ž

+44 (0)3300 555 444

πŸ“ 

+44 (0)3300 555 666

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

πŸ“ž

+44 (0)870 190 6777

🌍

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
oxyde de dimΓ©thyle; Γ©ther mΓ©thylique
EC: 204-065-8
115-10-6 20-30% ⚠️ Hazardous
SODIUM NITRITE
EC: 231-555-9
7632-00-0 0.1-0.25% ⚠️ Hazardous
Reaction mass of: 5-chloro-2-methyl- 4-isothiazolin-3-one [EC no. 247-500- 7] and 2-methyl-2H-isothiazol-3-one [EC no. 220-239-6] (3:1) 55965-84-9 0.0002-0.0015% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

If inhaled, remove to fresh air. Get medical attention if symptoms occur.

πŸ–οΈ Skin Contact

In case of contact, immediately flush skin with plenty of water. Get medical attention if symptoms occur.

πŸ‘οΈ Eye Contact

Flush eyes with water as a precaution. Get medical attention if irritation develops and persists.

Symptoms:

irritation develops and persists

🍽️ Ingestion/Swallowing

If swallowed, DO NOT induce vomiting. Get medical attention if symptoms occur. Rinse mouth thoroughly with water.

🚨 Immediate Medical Attention Required

In the case of accident or if you feel unwell, seek medical ad- vice immediately. When symptoms persist or in all cases of doubt seek medical advice. Treat symptomatically and supportively.

Medical Treatment

Treat symptomatically and supportively.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Aerosol containing a liquefied gas
Critical Property
πŸ“Š Physical State Data
aerosol
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Aerosol containing a liquefied gas
🎨 Colour
off-white
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Not available
πŸ‘ƒ Odor
characteristic
πŸ“Š Odor Threshold
No data available
πŸ§ͺ Ph
ca. 9.2 - 9.5 (20 ) Concentration: 100 % pH value is valid for liquid portion in the aerosol can
🧊 Melting Point
No data available
Critical Property
πŸ’¨ Boiling Point
Not applicable
Critical Property
πŸ”₯ Flash Point
317 Method: closed cup Flash point is only valid for liquid portion in the aerosol can.
Critical Property
πŸ“Š Freezing Point
No data available
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Not applicable
πŸ’¨ Vapor Pressure
3,850 hPa (25 )
πŸ“Š Vapor Density
Not available
πŸ“Š Relative Density
Not available
πŸ“Š Bulk Density
Not available
βš–οΈ Density
0.95 - 0.99 g/cm3 (20 )
Critical Property
πŸ”₯ Flammability
Extremely flammable aerosol.
πŸ“Š Upper Explosive Limit
26.2 %(V)
πŸ“Š Lower Explosive Limit
3.3 %(V)
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
226
πŸ“Š Decomposition Temperature
No data available
πŸ’§ Solubility
Not available
πŸ“Š Partition Coefficient
Not applicable
πŸ“Š Solubility In Water
No data available
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Kinematic Viscosity
Not applicable
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Minimize workplace exposure concentrations. If sufficient ventilation is unavailable, use with local exhaust ventilation. If advised by assessment of the local exposure potential, use only in an area equipped with ex-plosion-proof exhaust ventilation.

🧀 Hand Protection

Material : Fluorinated rubber, Break through time : 480 min, Glove thickness : 0.6 mm; Material : butyl-rubber, Break through time : 480 min, Glove thickness : 0.6 mm. Remarks : Choose gloves to protect hands against chemicals depending on the concentration and quantity of the hazardous sub- stance and specific to place of work. For special applications, we recommend clarifying the resistance to chemicals of the aforementioned protective gloves with the glove manufactur- er. Wash hands before breaks and at the end of workday.

πŸ‘οΈ Eye Protection

Please follow all applicable local/national requirements when selecting protective measures for a specific workplace. Wear the following personal protective equipment: Safety glasses Always wear eye protection when the potential for inadvertent eye contact with the product cannot be excluded. Equipment should conform to BS EN 166

😷 Respiratory Protection

If adequate local exhaust ventilation is not available or expo- sure assessment demonstrates exposures outside the rec- ommended guidelines, use respiratory protection. Equipment should conform to BS EN 137

🦺 Skin/Body Protection

Wear the following personal protective equipment: If assessment demonstrates that there is a risk of explosive atmospheres or flash fires, use flame retardant antistatic pro- tective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN 1950

πŸ“¦ Proper Shipping Name

AEROSOLS

πŸ“‹ Packing Group

Not assigned by regulation

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Weld Spray Perfect 400ml?

The signal word for this substance is "danger".

What is the physical form of Weld Spray Perfect 400ml?

Weld Spray Perfect 400ml is a aerosol containing a liquefied gas appearing as aerosol containing a liquefied gas with off-white color. It has characteristic odor.

What is Weld Spray Perfect 400ml used for?

Surface treatment, Preservative Professional use product

What are the hazard statements for Weld Spray Perfect 400ml?

This substance has 3 hazard statements: H222: Extremely flammable aerosol. H229: Pressurised container: May burst if heated. H336: May cause drowsiness or dizziness.

What is the melting point of Weld Spray Perfect 400ml?

The melting point is No data available and the boiling point is Not applicable.