Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PENETRATING OIL + MOS2
- Product Form
- Aerosol
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricants
Manufacturers & Suppliers
CRC Industries Europe bvba
manufacturer
Touwslagerstraat 1, 9240 Zele, Belgium
+32(0)52/45.60.11
CRC Industries Finland Oy
national supplier
Laurinkatu 57 A 23 B, 08100 Lohja
+358/(19)32.921
CRC Industries France
national supplier
6, avenue du marais, C.S. 90028, 95102 Argenteuil Cedex
01.34.11.20.00
CRC Industries Deutschland GmbH
national supplier
Südring 9, D-76473 Iffezheim
(07229) 303 0
CRC INDUSTRIES IBERIA S.L.U.
national supplier
GREMIO DEL CUERO-PARC.96, POLIGONO INDUSTR. DE HONTORIA, 40195 SEGOVIA
0034/921.427.546
CRC Industries Sweden
national supplier
Laxfiskevågen 16, 433 38 Partille
0046/31 706 84 80
Emergency Contacts
CRC Industries Europe, Belgium
+32(0)52/45.60.11
office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 926-141-6 | --- | 50 - 75% | Yes |
| mineral oil (IP 346 DMSO extract < 3%) | --- | 10 - 25% | No |
| carbon dioxide EC: 204-696-9 | 124-38-9 | 1 - 5% | Yes |
| sulfonic acids,petroleum,sodium salts EC: 271-781-5 | 68608-26-4 | 1 - 5% | Yes |
A : substance with Community workplace exposure limit B : substance with national established workplace exposure limit G : exempted from the obligation to register in accordance with art.2(7)of REACH Regulation No 1907/2006 Q : The CAS-no is only an indicative identifier to be used outside the EU for global inventory entries.
First Aid Measures
Emergency procedures for chemical exposure incidents
IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell.
Symptoms: nausea, headaches and dizziness
Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention.
Symptoms: redness and pain
If substance has got into eyes, immediately wash out with plenty of water. If eye irritation persists: Get medical advice/attention.
Symptoms: redness and pain
If swallowed do not induce vomiting because of risk of aspiration into the lungs. If aspiration is suspected obtain immediate medical attention
Symptoms: sore throat, abdominal pain, nausea, vomiting
Immediate Medical Attention
If aspiration is suspected obtain immediate medical attention
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
foam, carbon dioxide or dry agent
Do not use water jet extinguishing media, due to the risk of spreading fire.
Aerosols may explode if heated above 50°C
Keep container(s) exposed to fire cool, by spraying with water
Firefighter Protection
In case of fire, do not breathe fumes
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter public sewers and watercourses
Absorb spillage in suitable inert material
Materials: suitable inert material
Related Products
Similar products with comparable safety profiles
Ultra Screwloose® Penetrating Oil - 11 oz
---
CRC® Penetrating Oil, 311 g
---
TETROSEAL WAX OIL
---
FUEL OIL LS
CAS: 68476-33-5
Diesel #2/Mineral Oil in Hexane
---
Molybube 87 EP 2
---
Base Oil Ultra - S2 (60 Neutral)
---
LOCTITE LB 8040 PENETRATING OIL known as LOCTITE® FREEZE & RELEASE Part
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and sources of ignition. Take precautionary measures against static discharges. Do not breathe aerosols or vapours. Ensure adequate ventilation. Avoid contact with skin and eyes. Wash thoroughly after use. Wear protective gloves/protective clothing/eye protection/face protection.
Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C. Keep out of reach of children.
Wash thoroughly after use.
Keep away from heat and sources of ignition. Take precautionary measures against static discharges. Equipment should be earthed. Use only non-sparking tools.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation. Keep away from heat and sources of ignition. Take precautionary measures against static discharges.
Depending on amount and duration of use and the risk of contact with the product the gloves manufacturer can assist you in the selection of the right glove material and breakthrough time. Recommended gloves: Nitrile
Wear safety eyewear according to EN 166.
In case of insufficient ventilation, wear suitable respiratory equipment. Recommended respiratory protection: Air purifying respirator equipped with organic gas/vapor cartridge (type A)
Depending on amount and duration of use and the risk of contact with the product the gloves manufacturer can assist you in the selection of the right glove material and breakthrough time.
Avoid release to the environment. Collect spillage.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
No hazardous reactions known if used for its intended purpose
No hazardous reactions known if used for its intended purpose
Avoid overheating
Strong oxidising agent
CO,CO2
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
This material and its container must be disposed of in a safe way. Do not discharge into drains or the environment, dispose to an authorised waste collection point.
This material and its container must be disposed of in a safe way. Do not discharge into drains or the environment, dispose to an authorised waste collection point.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Not applicable.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The Safety Data Sheet is compiled according to the current European requirements.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PENETRATING OIL + MOS2?
The signal word is warning.
What is the physical form of PENETRATING OIL + MOS2?
PENETRATING OIL + MOS2 is a co2 propelled liquid. appearing as co2 propelled liquid. with black. color. It has characteristic odor. odor.
What is PENETRATING OIL + MOS2 used for?
Lubricants
What are the hazard statements for PENETRATING OIL + MOS2?
This substance has 2 hazard statements:
- H223: Flammable aerosol.
- H229: Pressurised container: May burst if heated.