NextSDS Logo
Safety Data Sheet EN

PENETRATING OIL + MOS2

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PENETRATING OIL + MOS2
Product Form
Aerosol

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricants

Manufacturers & Suppliers

C

CRC Industries Europe bvba

manufacturer

Touwslagerstraat 1 9240 Zele Belgium

C

CRC Industries Finland Oy

national supplier

Laurinkatu 57 A 23 B, 08100 Lohja

+358/(19)32.921

C

CRC Industries France

national supplier

6, avenue du marais, C.S. 90028, 95102 Argenteuil Cedex

01.34.11.20.00

C

CRC Industries Deutschland GmbH

national supplier

Südring 9, D-76473 Iffezheim

(07229) 303 0

C

CRC INDUSTRIES IBERIA S.L.U.

national supplier

GREMIO DEL CUERO-PARC.96, POLIGONO INDUSTR. DE HONTORIA, 40195 SEGOVIA

0034/921.427.546

C

CRC Industries Sweden

national supplier

Laxfiskevägen 16, 433 38 Partille

0046/31 706 84 80

Emergency Contacts

CRC Industries Europe, Belgium

+32(0)52/45.60.11

(office hours)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Aerosol Cat. 2
Press. Gas (Comp.)
Not Classified
Not Classified

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H223 Flammable aerosol.
H229 Pressurised container: May burst if heated.

Precautionary Statements

P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
Protect from sunlight. Do not expose to temperatures exceeding 50°C/122°F.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
N/A --- 50 - 75% Yes
N/A --- 10 - 25% Yes
carbon dioxide EC: 204-696-9 124-38-9 1 - 5% Yes
sulfonic acids,petroleum,sodium salts EC: 271-781-5 68608-26-4 1 - 5% Yes

A : substance with Community workplace exposure limit B : substance with national established workplace exposure limit G : exempted from the obligation to register in accordance with art.2(7)of REACH Regulation No 1907/2006 Q : The CAS-no is only an indicative identifier to be used outside the EU for global inventory entries.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

IF INHALED: Remove person to fresh air and keep comfortable for breathing.

Symptoms: Excessive inhalation of solvent vapours may give rise to nausea, headaches and dizziness

Skin contact

Wash with plenty of soap and water.

Symptoms: May cause irritation. Symptoms : redness and pain

Eye contact

If substance has got into eyes, immediately wash out with plenty of water

Symptoms: May cause irritation. Symptoms : redness and pain

Ingestion

If swallowed do not induce vomiting because of risk of aspiration into the lungs.

Symptoms: After vomiting of swallowed product aspiration into lungs is likely. Solvents may induce chemical pneumonia. Symptoms : sore throat, abdominal pain, nausea, vomiting

Immediate Medical Attention

If eye irritation persists: Get medical advice/attention. If skin irritation occurs: Get medical advice/attention. Call a POISON CENTER or doctor/physician if you feel unwell. If aspiration is suspected obtain immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

foam, carbon dioxide or dry agent

Unsuitable media

Do not use water jet extinguishing media, due to the risk of spreading fire.

Specific hazards

Aerosols may explode if heated above 50°C Forms hazardous decomposition products CO,CO2

Instructions

Keep container(s) exposed to fire cool, by spraying with water

Firefighter Protection

In case of fire, do not breathe fumes

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Shut off all ignition sources Ensure adequate ventilation Wear suitable protective clothing and gloves.

Environmental

Do not allow to enter public sewers and watercourses If polluted water reaches drainage systems or water courses, immediately inform appropriate authorities

Cleanup methods

Absorb spillage in suitable inert material

Materials: suitable inert material

Related Substances

Similar chemicals with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from heat and sources of ignition Take precautionary measures against static discharges Equipment should be earthed Use explosion-proof electrical/ventilating/lighting/.../equipment. Use only non-sparking tools. Do not breathe aerosols or vapours. Ensure adequate ventilation Avoid contact with skin and eyes. Wash thoroughly after use Wear protective gloves/protective clothing/eye protection/face protection.

Storage

Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C. Keep out of reach of children.

Hygiene

Wash thoroughly after use

Fire prevention

Keep away from heat and sources of ignition Take precautionary measures against static discharges Equipment should be earthed Use explosion-proof electrical/ventilating/lighting/.../equipment. Use only non-sparking tools.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation; Keep away from heat and sources of ignition; Take precautionary measures against static discharges

Hands

Depending on amount and duration of use and the risk of contact with the product the gloves manufacturer can assist you in the selection of the right glove material and breakthrough time. Recommended gloves: Nitrile

Eyes

Wear safety eyewear according to EN 166.

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment. recommended respiratory protection: Air purifying respirator equiped with organic gas/vapor cartridge (type A)

Environmental

Avoid release to the environment. Collect spillage.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Evaporation Rate
---
Dynamic Viscosity
---
Solubility
---
Solubility In Fat
---
Boiling Point
Not available.
Lower Explosive Limit
Not available.
Metal Corrosion
---
Physical State
CO2 propelled liquid.
Relative Density
0.82 (@ 20°C).
Properties Status
---
Solubility In Water
Insoluble in water
Bulk Density
---
Odor Threshold
---
Freezing Point
---
Softening Point
---
Explosive Limits
---
Cloud Point
---
Vapor Pressure
Not available.
State Under Standard Conditions
---
Auto Ignition Temperature
> 200 °C
Solidification Point
---
Physical State Data
liquid
Voc Content
590 g/l
Molecular Weight
---
Odor
Characteristic odor.
Evaporation Rate
Not available.
Upper Explosive Limit
Not available.
Ph
Not applicable.
Decomposition Temperature
---
Partition Coefficient
---
Flash Point
> 70 °C
Melting Point
---
Density
---
Colour Intensity
---
Kinematic Viscosity
---
Vapor Density
---
Form
---
Appearance
CO2 propelled liquid.
Flammability
---
Crystallisation Point
---
Colour
Black.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

No hazardous reactions known if used for its intended purpose

Hazardous reactions

No hazardous reactions known if used for its intended purpose

Avoid

Avoid overheating

Incompatible

Strong oxidising agent

Decomposition

CO,CO2

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

This material and its container must be disposed of in a safe way. Do not discharge into drains or the environment, dispose to an authorised waste collection point.

Disposal

This material and its container must be disposed of in a safe way. Do not discharge into drains or the environment, dispose to an authorised waste collection point.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2.1
Packing Group
Not applicable.
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PENETRATING OIL + MOS2?

The signal word is warning.

What is the physical form of PENETRATING OIL + MOS2?

PENETRATING OIL + MOS2 is a co2 propelled liquid. appearing as co2 propelled liquid. with black. color. It has characteristic odor. odor.

What is PENETRATING OIL + MOS2 used for?

Lubricants

What are the hazard statements for PENETRATING OIL + MOS2?

This substance has 2 hazard statements:

  • H223: Flammable aerosol.
  • H229: Pressurised container: May burst if heated.

Compliance Scan