Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PENETRATING OIL + MOS2
- Product Form
- Aerosol
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricants
Manufacturers & Suppliers
CRC Industries Europe bvba
manufacturer
Touwslagerstraat 1 9240 Zele Belgium
CRC Industries Finland Oy
national supplier
Laurinkatu 57 A 23 B, 08100 Lohja
+358/(19)32.921
CRC Industries France
national supplier
6, avenue du marais, C.S. 90028, 95102 Argenteuil Cedex
01.34.11.20.00
CRC Industries Deutschland GmbH
national supplier
Südring 9, D-76473 Iffezheim
(07229) 303 0
CRC INDUSTRIES IBERIA S.L.U.
national supplier
GREMIO DEL CUERO-PARC.96, POLIGONO INDUSTR. DE HONTORIA, 40195 SEGOVIA
0034/921.427.546
CRC Industries Sweden
national supplier
Laxfiskevägen 16, 433 38 Partille
0046/31 706 84 80
Emergency Contacts
CRC Industries Europe, Belgium
+32(0)52/45.60.11
(office hours)
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | 50 - 75% | Yes |
| N/A | --- | 10 - 25% | Yes |
| carbon dioxide EC: 204-696-9 | 124-38-9 | 1 - 5% | Yes |
| sulfonic acids,petroleum,sodium salts EC: 271-781-5 | 68608-26-4 | 1 - 5% | Yes |
A : substance with Community workplace exposure limit B : substance with national established workplace exposure limit G : exempted from the obligation to register in accordance with art.2(7)of REACH Regulation No 1907/2006 Q : The CAS-no is only an indicative identifier to be used outside the EU for global inventory entries.
First Aid Measures
Emergency procedures for chemical exposure incidents
IF INHALED: Remove person to fresh air and keep comfortable for breathing.
Symptoms: Excessive inhalation of solvent vapours may give rise to nausea, headaches and dizziness
Wash with plenty of soap and water.
Symptoms: May cause irritation. Symptoms : redness and pain
If substance has got into eyes, immediately wash out with plenty of water
Symptoms: May cause irritation. Symptoms : redness and pain
If swallowed do not induce vomiting because of risk of aspiration into the lungs.
Symptoms: After vomiting of swallowed product aspiration into lungs is likely. Solvents may induce chemical pneumonia. Symptoms : sore throat, abdominal pain, nausea, vomiting
Immediate Medical Attention
If eye irritation persists: Get medical advice/attention. If skin irritation occurs: Get medical advice/attention. Call a POISON CENTER or doctor/physician if you feel unwell. If aspiration is suspected obtain immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
foam, carbon dioxide or dry agent
Do not use water jet extinguishing media, due to the risk of spreading fire.
Aerosols may explode if heated above 50°C Forms hazardous decomposition products CO,CO2
Keep container(s) exposed to fire cool, by spraying with water
Firefighter Protection
In case of fire, do not breathe fumes
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Shut off all ignition sources Ensure adequate ventilation Wear suitable protective clothing and gloves.
Do not allow to enter public sewers and watercourses If polluted water reaches drainage systems or water courses, immediately inform appropriate authorities
Absorb spillage in suitable inert material
Materials: suitable inert material
Related Substances
Similar chemicals with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and sources of ignition Take precautionary measures against static discharges Equipment should be earthed Use explosion-proof electrical/ventilating/lighting/.../equipment. Use only non-sparking tools. Do not breathe aerosols or vapours. Ensure adequate ventilation Avoid contact with skin and eyes. Wash thoroughly after use Wear protective gloves/protective clothing/eye protection/face protection.
Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C. Keep out of reach of children.
Wash thoroughly after use
Keep away from heat and sources of ignition Take precautionary measures against static discharges Equipment should be earthed Use explosion-proof electrical/ventilating/lighting/.../equipment. Use only non-sparking tools.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation; Keep away from heat and sources of ignition; Take precautionary measures against static discharges
Depending on amount and duration of use and the risk of contact with the product the gloves manufacturer can assist you in the selection of the right glove material and breakthrough time. Recommended gloves: Nitrile
Wear safety eyewear according to EN 166.
In case of insufficient ventilation, wear suitable respiratory equipment. recommended respiratory protection: Air purifying respirator equiped with organic gas/vapor cartridge (type A)
Avoid release to the environment. Collect spillage.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
No hazardous reactions known if used for its intended purpose
No hazardous reactions known if used for its intended purpose
Avoid overheating
Strong oxidising agent
CO,CO2
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
This material and its container must be disposed of in a safe way. Do not discharge into drains or the environment, dispose to an authorised waste collection point.
This material and its container must be disposed of in a safe way. Do not discharge into drains or the environment, dispose to an authorised waste collection point.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Not applicable.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PENETRATING OIL + MOS2?
The signal word is warning.
What is the physical form of PENETRATING OIL + MOS2?
PENETRATING OIL + MOS2 is a co2 propelled liquid. appearing as co2 propelled liquid. with black. color. It has characteristic odor. odor.
What is PENETRATING OIL + MOS2 used for?
Lubricants
What are the hazard statements for PENETRATING OIL + MOS2?
This substance has 2 hazard statements:
- H223: Flammable aerosol.
- H229: Pressurised container: May burst if heated.