NextSDS Logo
Safety Data Sheet EN

PENETRATING OIL + MOS2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PENETRATING OIL + MOS2
Product Form
Aerosol

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricants

Manufacturers & Suppliers

C

CRC Industries Europe bvba

manufacturer

Touwslagerstraat 1, 9240 Zele, Belgium

+32(0)52/45.60.11

C

CRC Industries Finland Oy

distributor

Laurinkatu 57 A 23 B, 08100 Lohja

+358/(19)32.921

C

CRC Industries France

distributor

6, avenue du marais, C.S. 90028, 95102 Argenteuil Cedex

01.34.11.20.00

C

CRC Industries Deutschland GmbH

distributor

Südring 9, D-76473 Ilfezheim

(07229) 303 0

C

CRC INDUSTRIES IBERIA S.L.U.

distributor

GREMIO DEL CUERO-PARC.96, POLIGONO INDUSTR. DE HONTORIA, 40195 SEGOVIA

0034/921.427.546

C

CRC Industries Sweden

distributor

Laxfiskevågen 16, 433 38 Partille

0046/31 706 84 80

Emergency Contacts

CRC Industries Europe, Belgium

+32(0)52/45.60.11

office hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Aerosol Cat. 2
Not Classified
Not Classified

GHS Pictograms

GHS02 - Flammable

GHS02

Hazard Statements

H223 Flammable aerosol.
H229 Pressurised container: May burst if heated.

Precautionary Statements

P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P410 Protect from sunlight. Do not expose to temperatures exceeding 50°C/122°F.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C11-C14, n-alkanes, isoalkanes, cyclics, < 2% aromatics EC: 926-141-6 --- 50 - 75% Yes
mineral oil (IP 346 DMSO extract < 3%) --- 10 - 25% No
carbon dioxide EC: 204-696-9 124-38-9 1 - 5% Yes
sulfonic acids,petroleum,sodium salts EC: 271-781-5 68608-26-4 1 - 5% Yes

A : substance with Community workplace exposure limit B : substance with national established workplace exposure limit G : exempted from the obligation to register in accordance with art.2(7)of REACH Regulation No 1907/2006 Q : The CAS-no is only an indicative identifier to be used outside the EU for global inventory entries.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell.

Symptoms: Excessive inhalation of solvent vapours may give rise to nausea, headaches and dizziness

Skin contact

Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention.

Symptoms: May cause irritation. Symptoms : redness and pain

Eye contact

If substance has got into eyes, immediately wash out with plenty of water. If eye irritation persists: Get medical advice/attention.

Symptoms: May cause irritation. Symptoms : redness and pain

Ingestion

If swallowed do not induce vomiting because of risk of aspiration into the lungs.

Symptoms: After vomiting of swallowed product aspiration into lungs is likely. Solvents may induce chemical pneumonia. Symptoms : sore throat, abdominal pain, nausea, vomiting

Immediate Medical Attention

If aspiration is suspected obtain immediate medical attention. If symptoms persist always call a doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

foam, carbon dioxide or dry agent

Unsuitable media

Do not use water jet extinguishing media, due to the risk of spreading fire.

Specific hazards

Aerosols may explode if heated above 50°C

Instructions

Keep container(s) exposed to fire cool, by spraying with water

Firefighter Protection

In case of fire, do not breathe fumes

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter public sewers and watercourses

Cleanup methods

Absorb spillage

Materials: suitable inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from heat and sources of ignition, Take precautionary measures against static discharges, Do not breathe aerosols or vapours, Avoid contact with skin and eyes, Wash thoroughly after use, Wear protective gloves/protective clothing/eye protection/face protection.

Storage

Pressurized container : protect from sunlight and do not expose to temperatures exceeding 50°C. Keep out of reach of children.

Hygiene

Wash thoroughly after use

Fire prevention

Keep away from heat and sources of ignition, Take precautionary measures against static discharges, Use only non-sparking tools.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, Keep away from heat and sources of ignition, Take precautionary measures against static discharges

Hands

Depending on amount and duration of use and the risk of contact with the product the gloves manufacturer can assist you in the selection of the right glove material and breakthrough time. Recommended gloves: Nitrile

Eyes

Wear safety eyewear according to EN 166.

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment. Air purifying respirator equipped with organic gas/vapor cartridge (type A)

Skin/Body

Depending on amount and duration of use and the risk of contact with the product the gloves manufacturer can assist you in the selection of the right glove material and breakthrough time.

Environmental

Avoid release to the environment. Collect spillage.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Evaporation Rate
Not available.
Colour Intensity
---
Density
---
Kinematic Viscosity
Not available.
Auto Ignition Temperature
> 200 °C
Cloud Point
---
Dynamic Viscosity
---
Ph
Not applicable.
Odor Threshold
---
Appearance
CO2 propelled liquid.
Boiling Point
Not available.
Flammability
---
Vapor Pressure
Not available.
Solubility In Fat
---
State Under Standard Conditions
---
Solubility In Water
Insoluble in water
Relative Density
0.82 (@ 20°C)
Solidification Point
---
Melting Point
---
Voc Content
590 g/l
Upper Explosive Limit
Not available.
Colour
Black.
Odor
Characteristic odor.
Physical State Data
aerosol
Vapor Density
---
Physical State
CO2 propelled liquid.
Form
---
Flash Point
> 70 °C
Bulk Density
---
Metal Corrosion
---
Partition Coefficient
---
Properties Status
---
Freezing Point
---
Lower Explosive Limit
Not available.
Molecular Weight
---
Relative Evaporation Rate
---
Decomposition Temperature
---
Softening Point
---
Explosive Limits
---
Solubility
---
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Reactivity

No hazardous reactions known if used for its intended purpose

Hazardous reactions

No hazardous reactions known if used for its intended purpose

Avoid

Avoid overheating

Incompatible

Strong oxidising agent

Decomposition

CO,CO2

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

This material and its container must be disposed of in a safe way. Do not discharge into drains or the environment, dispose to an authorised waste collection point.

Disposal

This material and its container must be disposed of in a safe way. Do not discharge into drains or the environment, dispose to an authorised waste collection point.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2.1
Packing Group
Not applicable.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The Safety Data Sheet is compiled according to the current European requirements.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PENETRATING OIL + MOS2?

The signal word is warning.

What is the physical form of PENETRATING OIL + MOS2?

PENETRATING OIL + MOS2 is a co2 propelled liquid. appearing as co2 propelled liquid. with black. color. It has characteristic odor. odor.

What is PENETRATING OIL + MOS2 used for?

Lubricants

What are the hazard statements for PENETRATING OIL + MOS2?

This substance has 2 hazard statements:

  • H223: Flammable aerosol.
  • H229: Pressurised container: May burst if heated.