NextSDS Logo
Safety Data Sheet EN

CaFix seal

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CaFix seal

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Waterproofing, Professional uses: Public domain (administration, education, entertainment, services, craftsmen), Roller application or brushing

Manufacturers & Suppliers

CaPlast GmbH logo

CaPlast GmbH

manufacturer

Magdheide 7, 59394 Nordkirchen

(+49) 25 99 / 91 3 - 0

http://www.caplast.de

Emergency Contacts

Giftinformationszentrum der Länder Rheinland-Pfalz und Hessen

+49 (0)6131 / 19 24 0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Eye Irrit. Cat. 2 H319
Resp. Sens. Cat. 1 H334
Skin Sens. Cat. 1 H317
STOT RE Cat. 1 H372
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS08 - Serious health hazard

GHS08

Hazard Statements

H226 Flammable liquid and vapour.
H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.
H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.
H372 Causes damage to organs through prolonged or repeated exposure.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P241 Use explosion-proof [electrical/ventilating/lighting] equipment.
P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture: consisting of the following components.

Chemical Name CAS Number Concentration Hazardous
barium sulphate EC: 231-784-4 7727-43-7 25 - 50% No
Poly[oxy(methyl-1,2-ethanediyl)], alpha-hydro-omega-hydroxy-, polymer with 2,4-diisocyanato-1-methylbenzene EC: 609-378-7 37273-56-6 25 - 50% Yes
Hydrocarbons, C9-C12, n-alkanes, isoalkanes, cyclics, aromatics (2-25%) EC: 919-446-0 --- 2.5 - 10% Yes
xylene EC: 215-535-7 1330-20-7 2.5 - 10% Yes
Kieselguhr, soda ash flux-calcined EC: 272-489-0 68855-54-9 2.5 - 10% Yes
ethylbenzene EC: 202-849-4 100-41-4 0.5 - 2.5% Yes
4-isocyanatosulphonyltoluene EC: 223-810-8 4083-64-1 0.5 - 2.5% Yes
hydrocarbons, C9, aromatic EC: 918-668-5 --- 0.5 - 2.5% Yes
2-ethylhexyl (6-isocyanatohexyl)-carbamate EC: 247-735-5 26488-60-8 0.5% Yes
4-methyl-m-phenylene diisocyanate EC: 209-544-5 584-84-9 0.5% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air and to be sure call for a doctor. In case of unconsciousness place patient stably in side position for transportation. Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly. Seek medical treatment.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor. Protect unharmed eye.

Ingestion

If symptoms persist consult doctor.

Immediate Medical Attention

Seek medical treatment for skin contact. Consult a doctor for inhalation, eye contact, or if symptoms persist after swallowing.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, sand, extinguishing powder. ABC powder. Alcohol resistant foam. CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Use fire extinguishing methods suitable to surrounding conditions.

Unsuitable media

Water with full jet

Specific hazards

During heating or in case of fire poisonous gases are produced.

Firefighter Protection

Do not inhale explosion gases or combustion gases.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow product to reach sewage system or any water course. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material. Do not flush with water or aqueous cleansing agents.

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Use only in well ventilated areas. Keep receptacles tightly sealed. Prevent formation of aerosols.

Storage

Store in cool, dry place in tightly closed receptacles. Protect from frost. Provide solvent resistant, sealed floor.

Hygiene

Store away from foodstuffs.

Fire prevention

Protect against electrostatic charges. Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves. Only use chemical-protective gloves with CE-labelling of category III. Avoid direct contact with the chemical/ the product/ the preparation by organisational measures. Check protective gloves prior to each use for their proper condition. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. After use of gloves apply skin-cleaning agents and skin cosmetics. Material of gloves: Butyl rubber, BR. Recommended thickness of the material: ≥ 0.5 mm. Penetration time of glove material: at least 480 minutes (Permeation according to EN 374 Part 3: Level≥6).

Eyes

Tightly sealed goggles

Respiratory

Use suitable respiratory protective device when high concentrations are present. Not necessary if room is well-ventilated. Use suitable respiratory protective device in case of insufficient ventilation. Filter A/P2

Skin/Body

Protective work clothing. Impervious protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Softening Point
---
Boiling Point
137 °C
Physical State
Fluid
Voc Content
19.08 %
Physical State Data
liquid
Colour Intensity
---
Appearance
---
Flash Point
24 °C
Decomposition Temperature
Not determined.
Cloud Point
---
Colour
According to product specification
Kinematic Viscosity
Not determined.
Odor
Characteristic
Ph
Not determined.
Freezing Point
Undetermined.
Bulk Density
---
Relative Density
Not determined.
State Under Standard Conditions
---
Explosive Limits
---
Odor Threshold
Not determined.
Solubility In Water
Not determined.
Solubility In Fat
---
Lower Explosive Limit
Not determined.
Relative Evaporation Rate
---
Vapor Density
Not determined.
Partition Coefficient
Not determined.
Solubility
---
Vapor Pressure
---
Evaporation Rate
Not determined.
Molecular Weight
---
Upper Explosive Limit
Not determined.
Density
Not determined.
Dynamic Viscosity
Not determined.
Form
Fluid
Melting Point
Undetermined.
Crystallisation Point
---
Properties Status
---
Auto Ignition Temperature
Product is not selfigniting.
Flammability
Not applicable.
Metal Corrosion
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Disposal

Must not be disposed together with household garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1993
Shipping Name
FLAMMABLE LIQUID, N.O.S. (ETHYLBENZENE, XYLENES)
Transport Class
3
Packing Group
III
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CaFix seal?

The signal word is danger.

What is the physical form of CaFix seal?

CaFix seal is a fluid with according to product specification color. It has characteristic odor.

What is CaFix seal used for?

Waterproofing, Professional uses: Public domain (administration, education, entertainment, services, craftsmen), Roller application or brushing

What are the hazard statements for CaFix seal?

This substance has 6 hazard statements:

  • H226: Flammable liquid and vapour.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
  • H372: Causes damage to organs through prolonged or repeated exposure.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of CaFix seal?