NextSDS Logo
Ru

Rust Seal

NO SIGNAL WORD Liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Rust Seal
Product Code
BDS002630BU

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Professional use; Anti Corrosion Products

Overview

Rust Seal is a viscous liquid. substance commonly used professional use; anti corrosion products.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P102: Keep out of reach of children.
  • P273: Avoid release to the environment.
  • P501: Dispose of contents/container to a hazardous or special waste collection point, in accordance with local, regional, national and/or international regulation.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

CRC Industries Europe B.V. company logo - Safety Data Sheet supplier organization

CRC Industries Europe B.V.

undefined

Touwslagerstraat 1 9240 Zele Belgium

BE

+32(0)52/45.00.34

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32(0)52/45.60.11

BE

9-17h CET

Centre Anti-Poisons/Antigifcentrum

+32 70 245 245

BE

24/7

Please dial: 070 245 245 for any urgent questions about intoxication (free of charge 24/7)

Centre Anti-Poisons/Antigifcentrum

02 264 96 30

BE

if not accessible, dial: 02 264 96 30 (standard fee)

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Dipropylene glycol methyl ether
EC: 252-104-2
34590-94-8 2.5% Non-hazardous
Amines, tallow alkyl, ethoxylated 61791-26-2 0.25-1% Hazardous
3-aminopropyltriethoxysilane
EC: 213-048-4
919-30-2 0.1-1% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing. If signs/symptoms develop, get medical attention.

Skin Contact

Wash skin with plenty of water. Seek medical attention if irritation develops.

Symptoms:

irritation

Eye Contact

Rinse eyes with water as a precaution. Seek medical attention if irritation develops.

Symptoms:

irritation

Ingestion/Swallowing

Call a poison center or a doctor if you feel unwell.

Symptoms:

unwell

Medical Treatment

Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Water spray. Dry powder. Foam. Carbon dioxide.

Unsuitable Extinguishing Media

Do not use a heavy water stream.

Fire Fighting Instructions

Move containers from fire area if it can be done without personal risk. Use standard firefighting procedures and consider the hazards of other involved materials.

Firefighter Protection Equipment

Do not attempt to take action without suitable protective equipment. Self-contained breathing apparatus. Complete protective clothing.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Ventilate spillage area. Evacuate unnecessary personnel. Ventilate area.

Small Spill Procedures

Take up small spills with dry chemical absorbent.

Large Spill Procedures

For large spills, confine the spill in a dike and charge it with wet sand or earth for subsequent safe disposal. Following product recovery, flush area with water.

Environmental Precautions

Avoid release to the environment. Avoid the spillage or runoff entering drains, sewers or watercourses.

Cleanup Methods

For large spills, confine the spill in a dike and charge it with wet sand or earth for subsequent safe disposal. Following product recovery, flush area with water. Take up small spills with dry chemical absorbent. Clean surface thoroughly to remove residual contamination.

Cleanup Materials:

wet sand or earth, dry chemical absorbent

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Odor Threshold
Not available
Voc Content
31 g/l
Bulk Density
Not available
Upper Explosive Limit
Not available
Relative Evaporation Rate
Not available
Partition Coefficient
Not applicable
State Under Standard Conditions
Not available
Appearance
Viscous liquid.
Explosive Limits
Not available
Form
Not available
Solubility In Water
soluble in water.
Solubility In Fat
Not available
Vapor Pressure
Not available
Freezing Point
Not available
Colour
Black.
Flammability
Non flammable.
Metal Corrosion
Not available
Physical State
Liquid
Critical Property
Colour Intensity
Not available
Flash Point
Not available
Critical Property
Decomposition Temperature
Not available
Density
1,03 g/cm³
Critical Property
Auto Ignition Temperature
> 200 °C
Physical State Data
liquid
Boiling Point
100 °C
Critical Property
Molecular Weight
Not available
Solubility
soluble in water.
Lower Explosive Limit
Not available
Softening Point
Not available
Relative Density
1,03
Solidification Point
Not available
Odor
Neutral.
Cloud Point
Not available
Vapor Density
Not available
Dynamic Viscosity
Not available
Ph
8 – 9
Melting Point
Not applicable
Critical Property
Crystallisation Point
Not available
Properties Status
Not available
Kinematic Viscosity
90 – 100 Krebs Unit
Evaporation Rate
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Wear personal protective equipment.

Ensure good ventilation of the work station.

Avoid prolonged exposure.

Handle in accordance with good industrial hygiene and safety procedures.

Storage Conditions

Store in a well-ventilated place.

Keep cool.

Keep container closed when not in use.

General Hygiene Measures

Do not eat, drink or smoke when using this product. Always wash hands after handling the product.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hand Protection

Wear suitable gloves tested to EN374. The breakthrough time of the glove should be longer than the total duration of product use. If work lasts longer than the breakthrough time, gloves should be changed part-way through. Nitrile gloves are recommended.

Eye Protection

Use eye protection according to EN 166. Safety glasses with side shields.

Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment. Approved organic vapour respirator. Filter type: A

Skin/Body Protection

Wear suitable protective clothing

Environmental Exposure Controls

Avoid release to the environment. Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stable under normal conditions.

Reactivity

The product is non-reactive under normal conditions of use, storage and transport.

Hazardous Reactions

No dangerous reactions known under normal conditions of use.

Conditions to Avoid

None under recommended storage and handling conditions (see section 7). Avoid temperatures exceeding the flash point.

Incompatible Materials

Strong oxidizing agents.

Hazardous Decomposition Products

Under normal conditions of storage and use, hazardous decomposition products should not be produced. Carbon oxides (CO, CO2).

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Rust Seal?

The signal word for this substance is "no signal word".

What is the physical form of Rust Seal?

Rust Seal is a liquid appearing as viscous liquid. with black. color. It has neutral. odor.

What is the solubility of Rust Seal?

soluble in water.

What is Rust Seal used for?

Professional use; Anti Corrosion Products

What are the hazard statements for Rust Seal?

This substance has 1 hazard statements: H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Rust Seal?

The melting point is Not applicable and the boiling point is 100 °C.