NextSDS Logo
DE

DEVELON HYDRAULIC POWER VG46

NO SIGNAL WORD LIQUID SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DEVELON HYDRAULIC POWER VG46
Product Code
76912

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Lubricant for hydraulic system.
Uses Advised Against
This product should not be used for other purposes than those specified without the advice of an expert.

Overview

DEVELON HYDRAULIC POWER VG46 is a viscous amber substance commonly used lubricant for hydraulic system..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

PETRONAS LUBRICANTS ITALY S.P.A.

undefined

Via Santena 1 10029 Villastellone (Torino)

IT

+39.01196131

+39.0119613313

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Answer Service

+44 1235 239670

GB

24h/7d

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Severely refined mineral and/or synthetic oils, additives.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Severely refined paraffinic mineral and synthetic oils, viscosity 40°C <=20.5 cSt N/A 1.5-2% Hazardous
Maleic anhydride
EC: 203-571-6
108-31-6 0.0001% Hazardous
Not classified oils N/A 90-100% Non-hazardous

Additional Information

Contains one or more among the following: CAS: 64742-65-0; 64742-54-7; 64742-55-8; 101316-72-7; 72623-87-1; 64741-89-5 / EC: 265-169-7; 265-157-1; 265-158-7; 309-877-7; 276-738-4; 265-091-3 / Registration numbers: 01-2119471299-27-XXXX; 01-2119484627-25-XXXX; 01-2119487077-29-XXXX; 01-2119489969-06-XXXX; 01-2119474889-13-XXXX; 01-2119487067-30-XXXX

Composition Notes

Hazardous components within the meaning of the CLP regulation and related classification: The harmonised classification as a carcinogen applies unless it can be shown that the substance contains less than 3 % of dimethyl sulphoxide extract as measured by IP 346 (“Determination of polycyclic aromatics in unused lubricating base oils and asphaltene free petroleum fractions – Dimethyl sulphoxide extraction refractive index method” Institute of Petroleum, London), in which case a classification in accordance with Title II of this Regulation shall be performed also for that hazard class. H-phrases and list of abbreviations: see heading 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Expose affected person to fresh air and obtain medical attention if necessary.

Skin Contact

Remove contaminated clothes and shoes and rinse thoroughly with plenty of water and soap.

Eye Contact

Rinse thoroughly with plenty of water for at least 10 minutes keeping eyelids open. Remove contact lenses if this can be done easily. Obtain medical attention in case of development and persistence of pain and redness. In case of contact with hot product, rinse thoroughly with plenty of water to dissipate heat. Obtain immediate medical attention to assess eye conditions and the correct treatment to be practiced.

Symptoms:

development and persistence of pain and redness

Ingestion/Swallowing

Do not induce vomiting to avoid aspiration into the respiratory tracts. Wash out thoroughly the mouth with water. Obtain immediate medical attention.

Immediate Medical Attention Required

Obtain medical attention in case of development and persistence of pain and redness (for eyes). Obtain immediate medical attention to assess eye conditions and the correct treatment to be practiced (for hot product eye contact). Obtain medical attention if necessary (for inhalation). Obtain immediate medical attention (for ingestion).

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Appearance
VISCOUS AMBER
Molecular Weight
Not available
Solidification Point
Not available
Physical State Data
liquid
Explosive Limits
Not available
Kinematic Viscosity
46.00 CST
Metal Corrosion
Not available
Flash Point
>200 °C (392 °F)
Critical Property
Colour Intensity
Not available
State Under Standard Conditions
Not available
Boiling Point
>250 °C (482 °F)
Critical Property
Solubility In Fat
N.A.
Lower Explosive Limit
N.A.
Softening Point
Not available
Decomposition Temperature
N.A.
Dynamic Viscosity
Not available
Upper Explosive Limit
N.A.
Vapor Density
N.A.
Odor
NOT RELEVANT
Ph
N.A.
Cloud Point
Not available
Solubility
Not available
Form
Not available
Partition Coefficient
N.A.
Freezing Point
N.A.
Crystallisation Point
Not available
Flammability
N.A.
Density
0.86 G/CM3
Critical Property
Vapor Pressure
N.A.
Auto Ignition Temperature
N.A.
Physical State
LIQUID
Critical Property
Colour
AMBER
Relative Density
Not available
Melting Point
N.A.
Critical Property
Evaporation Rate
Not available
Voc Content
N.A.
Solubility In Water
IMMISCIBLE
Bulk Density
Not available
Properties Status
Not available
Relative Evaporation Rate
Not available
Odor Threshold
NOT RELEVANT
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Avoid production and diffusion of mist and aerosol with utilization of localized ventilation/aspiration or other required precautions. Adopt all required precaution to avoid product immission in environment (e.g., blasting systems, catch basins, ...).

Hand Protection

Wear suitable gloves (i.e. neoprene, nitrile). Gloves should be changed when they show wear. The kind of gloves and the term of use must be decided from employer with regard to processing and to allow for DPI legislation and glove producer's indications. Wear gloves only with clean hands.

Eye Protection

Chemical goggles and face shield in case of oil splashes.

Respiratory Protection

None required under normal conditions of use. Use approved full face respirator with organic vapour filter cartridge if the recommended exposure limits are exceeded.

Skin/Body Protection

Wear suitable protective clothing (for further information, refer to CEN-EN 14605); change it immediately in case of large contamination and wash it before subsequent use.

Environmental Exposure Controls

Refer to technical precautions and also to sections 6.2, 6.3, 7.2, 12 and 13.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

The product is stable under normal conditions of use.

Reactivity

Read carefully all information provided in other sections of heading 10.

Hazardous Reactions

Not expected under normal conditions of use.

Conditions to Avoid

This product must be kept far from heat sources. In any case, avoid exposing product to temperatures above the flash point.

Incompatible Materials

Strong oxidizing agents, hard acids and bases.

Hazardous Decomposition Products

Oxides of carbon, compounds of sulphur, phosphorus, nitrogen and hydrogen sulfide.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DEVELON HYDRAULIC POWER VG46?

The signal word for this substance is "no signal word".

What is the physical form of DEVELON HYDRAULIC POWER VG46?

DEVELON HYDRAULIC POWER VG46 is a liquid appearing as viscous amber with amber color. It has not relevant odor.

What is DEVELON HYDRAULIC POWER VG46 used for?

Lubricant for hydraulic system.

What is the melting point of DEVELON HYDRAULIC POWER VG46?

The melting point is N.A. and the boiling point is >250 °C (482 °F).