Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE SF 7649
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
activator
Manufacturers & Suppliers
Henkel Australia Pty Ltd
national supplier
135-141 Canterbury Road, Kilsyth, Victoria, 3137, Australia
+61 (3) 9724 6444
Emergency Contacts
Emergency Contact
1800 032 379
24 HOUR
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
solvent
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| acetone | 67-64-1 | 60 - 100% | No |
| butane | 106-97-8 | 10 - 30% | No |
| 2-ethylhexanoic acid, copper salt | 22221-10-9 | 1% | No |
| 2-ethylhexanoic acid | 149-57-5 | 3% | No |
Solvent based activator.
Notes
Type of preparation: Solvent based activator.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air in case of accidental inhalation of vapours. Seek medical advice.
Remove contaminated clothing and footwear. Wash with soap and water. Seek medical advice. Wash clothing before reuse.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Seek medical advice.
Do not induce vomiting. Have victim rinse mouth thoroughly with water. Seek medical advice.
Immediate Medical Attention
Seek medical advice.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, Carbon dioxide, Dry chemical.
WARNING FLAMMABLE! Contents under pressure. Closed containers may rupture (due to build up of pressure) when exposed to extreme heat.
Use water spray to keep fire exposed containers cool and disperse vapors.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter in surface / ground water.
Remove the absorbed material, and place in an appropriate chemical waste container for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid breathing vapors or mists of this product. Avoid contact with eyes, skin and clothing. Keep away from heat, spark and flame. Vapors will accumulate readily and may ignite explosively.
Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use. Do not puncture, incinerate, or expose to temperatures above 48.9 °C (120 °F).
Keep away from heat, spark and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ventilate working rooms thoroughly. Avoid naked flames, sparking and sources of ignition. Switch off electrical devices. Do not smoke, do not weld.
Chemical resistant, impermeable gloves. Suitable protective gloves. Please note that in practice the working life of chemical resistant gloves may be considerably reduced as a result of many influencing factors (e.g. temperature). Suitable risk assessment should be carried out by the end user. If signs of wear and tear are noticed then the gloves should be replaced. Butyl rubber gloves.
Safety goggles or safety glasses with side shields.
If inhalation risk exists, wear a respirator or air supplied mask complying with the requirements of AS/NZS 1715 and AS/NZS 1716.
Wear suitable protective clothing.
Do not empty waste into waste water drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of temperature and pressure.
Will not occur.
Keep away from heat, spark and flame. Do not puncture, incinerate, or expose to temperatures above 48.9 °C (120 °F).
Strong oxidizing agents. Acids.
Thermal decomposition can lead to release of irritating gases and vapors. carbon monoxide, carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Do not puncture or incinerate pressurized containers.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE SF 7649?
The signal word is danger.
What is the physical form of LOCTITE SF 7649?
LOCTITE SF 7649 is a aerosol appearing as green aerosol with green color. It has characteristic odor.
What is LOCTITE SF 7649 used for?
activator
What are the hazard statements for LOCTITE SF 7649?
This substance has 5 hazard statements:
- EUH066: Repeated exposure may cause skin dryness or cracking.
- H222: Extremely flammable aerosol.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.