Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
LOCTITE SF 7649 is a green aerosol substance commonly used activator.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS09
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H222: Extremely flammable aerosol.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
Precautionary Statements
- P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- P211: Do not spray on an open flame or other ignition source.
- P251: Do not pierce or burn, even after use.
- P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
- P264: Wash hands thoroughly after handling.
- P271: Use only outdoors or in a well-ventilated area.
- P273: Avoid release to the environment.
- P280: Wear eye protection/face protection.
- IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or physician if you feel unwell.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P337+P313: If eye irritation persists: Get medical advice/attention.
- P391: Collect spillage.
- P403+P233: Store in a well-ventilated place. Keep container tightly closed.
- P405: Store locked up.
- P410+P412: Protect from sunlight. Do not expose to temperatures exceeding 50C/122F.
- P501: Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Henkel Australia Pty Ltd
undefined
135-141 Canterbury Road Kilsyth, Victoria, 3137 Australia
AU
+61 (3) 9724 6444
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
1800 032 379
AU
24 HOUR
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
MixtureGeneral Composition
solvent
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| acetone | 67-64-1 | 60-100% | โ Non-hazardous |
| butane | 106-97-8 | 10-30% | โ Non-hazardous |
| 2-ethylhexanoic acid, copper salt | 22221-10-9 | 1% | โ Non-hazardous |
| 2-ethylhexanoic acid | 149-57-5 | 3% | โ Non-hazardous |
Composition Notes
Solvent based activator.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move to fresh air in case of accidental inhalation of vapours. Seek medical advice.
๐๏ธ Skin Contact
Remove contaminated clothing and footwear. Wash with soap and water. Seek medical advice. Wash clothing before reuse.
๐๏ธ Eye Contact
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Seek medical advice.
๐ฝ๏ธ Ingestion/Swallowing
Do not induce vomiting. Have victim rinse mouth thoroughly with water. Seek medical advice.
Medical Treatment
Treat symptomatically and supportively.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Ventilate working rooms thoroughly. Avoid naked flames, sparking and sources of ignition. Switch off electrical devices.
๐งค Hand Protection
Chemical resistant, impermeable gloves. Suitable protective gloves. Please note that in practice the working life of chemical resistant gloves may be considerably reduced as a result of many influencing factors (e.g. temperature). Suitable risk assessment should be carried out by the end user. If signs of wear and tear are noticed then the gloves should be replaced. Butyl rubber gloves.
๐๏ธ Eye Protection
Safety goggles or safety glasses with side shields.
๐ท Respiratory Protection
If inhalation risk exists, wear a respirator or air supplied mask complying with the requirements of AS/NZS 1715 and AS/NZS 1716.
๐ฆบ Skin/Body Protection
Wear suitable protective clothing.
๐ Environmental Exposure Controls
Do not empty waste into waste water drains.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
1950
๐ฆ Proper Shipping Name
AEROSOLS
โ ๏ธ Transport Hazard Class
2.1
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for LOCTITE SF 7649?
The signal word for this substance is "danger".
What is the physical form of LOCTITE SF 7649?
LOCTITE SF 7649 is a aerosol appearing as green aerosol with green color. It has characteristic odor.
What is LOCTITE SF 7649 used for?
activator
What are the hazard statements for LOCTITE SF 7649?
This substance has 4 hazard statements: H222: Extremely flammable aerosol. H319: Causes serious eye irritation. H336: May cause drowsiness or dizziness. H411: Toxic to aquatic life with long lasting effects.