NextSDS Logo
Safety Data Sheet EN

LOCTITE SF 7840

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LOCTITE SF 7840
Synonyms
Loctite 7840 5lt PL/RU/HU/HR

Regulatory Identifiers

CAS Number
N/A
UFI Code
Y5G7-SXF9-J20R-N0DE

Identified Uses

Epoxy adhesive

Manufacturers & Suppliers

Henkel AG & Co. KGaA logo

Henkel AG & Co. KGaA

Henkelstr. 67 40589 Düsseldorf Germany

+49 211 797 0

www.mysds.henkel.com

Emergency Contacts

Henkel information service

+49-(0)211-797-3350

around-the-clock

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Skin Sens. Cat. 1 H317
Muta. Cat. 2 H341
Repr. Cat. 2 H361d
Aquatic Chronic Cat. 2 H411
Endocrine disruptor for human health Cat. 1 EUH380
Endocrine disruptor for environment Cat. 1 EUH430

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

GHS09 - Environmental hazard

GHS09

Hazard Statements

H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.
H341 Suspected of causing genetic defects.
H361d Suspected of damaging the unborn child.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P201 Obtain special instructions before use.
P273 Avoid release to the environment.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P308 + P313 IF exposed or concerned: Get medical advice/attention.
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.
P337 + P313 If eye irritation persists: Get medical advice/attention.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2,2'-[(1-methylethylidene)bis(4,1-phenyleneoxymethylene)]bisoxirane EC: 216-823-5 1675-54-3 25 - 50% Yes
Neodecanoic acid, oxiranylmethyl ester EC: 247-979-2 26761-45-5 5 - 10% Yes
RP Bisphenol F-epichlorohydrin resin, MW<=700 28064-14-4 1 - 5% Yes
4,4'-Isopropylidenediphenol EC: 201-245-8 80-05-7 0.1 - 0.3% Yes

Notes

If no ATE values are displayed, please refer to LD/LC50 values in Section 11. For full text of the H - statements and other abbreviations see section 16 "Other information".

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If symptoms persist, seek medical advice.

Skin contact

Rinse with running water and soap. Obtain medical attention if irritation persists.

Symptoms: Rash, Urticaria. Redness, inflammation.

Eye contact

Rinse immediately with plenty of running water (for 10 minutes), seek medical attention from a specialist.

Symptoms: Irritation, conjunctivitis.

Ingestion

Rinse mouth, drink 1-2 glasses of water, do not induce vomiting, consult a doctor.

Immediate Medical Attention

If symptoms persist (inhalation), seek medical advice. Obtain medical attention if irritation persists (skin). Seek medical attention from a specialist (eye). Consult a doctor (ingestion).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

water, carbon dioxide, foam, powder

Unsuitable media

High pressure waterjet

Specific hazards

In the event of a fire, carbon monoxide (CO), carbon dioxide (CO2) and nitrogen oxides (NOx) can be released.

Instructions

In case of fire, keep containers cool with water spray.

Firefighter Protection

Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin and eyes. Wear protective equipment. Ensure adequate ventilation.

Small spill

For small spills wipe up with paper towel and place in container for disposal.

Large spill

For large spills absorb onto inert absorbent material and place in sealed container for disposal.

Environmental

Do not empty into drains / surface water / ground water.

Cleanup methods

wipe up with paper towel; absorb onto inert absorbent material

Materials: paper towel; inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid skin and eye contact. See advice in section 8

Storage

Ensure good ventilation/extraction. Refer to Technical Data Sheet.

Hygiene

Wash hands before work breaks and after finishing work. Do not eat, drink or smoke while working. Good industrial hygiene practices should be observed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation/extraction.

Hands

Chemical-resistant protective gloves (EN 374). Suitable materials for short-term contact or splashes (recommended: at least protection index 2, corresponding to > 30 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) Suitable materials for longer, direct contact (recommended: protection index 6, corresponding to > 480 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) This information is based on literature references and on information provided by glove manufacturers, or is derived by analogy with similar substances. Please note that in practice the working life of chemical-resistant protective gloves may be considerably shorter than the permeation time determined in accordance with EN 374 as a result of the many influencing factors (e.g. temperature). If signs of wear and tear are noticed then the gloves should be replaced.

Eyes

Safety glasses with sideshields or chemical safety goggles should be worn if there is a risk of splashing. Protective eye equipment should conform to EN166.

Respiratory

Ensure adequate ventilation. An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly ventilated area Filter type: A (EN 14387)

Skin/Body

Wear suitable protective clothing. Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
---
Freezing Point
---
Flammability
The product is not flammable.
Partition Coefficient
Not applicable Mixture
Evaporation Rate
---
Ph
Not applicable, Product is non-soluble (in water).
Odor Threshold
---
Bulk Density
---
Boiling Point
> 148,9 °C (> 300 °F)
Flash Point
> 93 °C (> 199.4 °F)
Physical State Data
liquid
Crystallisation Point
---
Colour
Red
Solubility
Insoluble
Physical State
liquid
State Under Standard Conditions
---
Vapor Density
---
Auto Ignition Temperature
Not applicable, The product is not flammable.
Form
paste
Softening Point
---
Dynamic Viscosity
---
Properties Status
---
Kinematic Viscosity
> 20 mm2/s
Metal Corrosion
---
Solubility In Fat
---
Relative Evaporation Rate
---
Vapor Pressure
< 1,0 mm hg
Density
1,33 g/cm3
Voc Content
---
Cloud Point
---
Colour Intensity
---
Odor
Mild
Decomposition Temperature
Not applicable, Substance/mixture is not self-reactive, no organic peroxide and does not decompose under foreseen conditions of use
Solubility In Water
Insoluble
Upper Explosive Limit
Not applicable, The product is not flammable.
Solidification Point
< -20 °C (< -4 °F)
Melting Point
Not applicable, Product is a liquid
Relative Density
---
Appearance
---
Explosive Limits
---
Lower Explosive Limit
Not applicable, The product is not flammable.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Reacts with strong oxidants. Reaction with strong acids.

Hazardous reactions

See section reactivity

Avoid

Stable under normal conditions of storage and use.

Incompatible

See section reactivity.

Decomposition

carbon oxides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose of in accordance with local and national regulations. Do not empty into drains / surface water / ground water.

Waste Codes

08 04 09* waste adhesives and sealants containing organic solvents and other dangerous substances EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3082
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
Transport Class
9
Packing Group
III
ADR

not applicable

IMDG

not applicable

IATA

not applicable

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is LOCTITE SF 7840 known by?

LOCTITE SF 7840 is also known as: Loctite 7840 5lt PL/RU/HU/HR

What is the hazard signal word for LOCTITE SF 7840?

The signal word is danger.

What is the physical form of LOCTITE SF 7840?

LOCTITE SF 7840 is a liquid with red color. It has mild odor.

What is the solubility of LOCTITE SF 7840?

Insoluble

What is LOCTITE SF 7840 used for?

Epoxy adhesive

What are the hazard statements for LOCTITE SF 7840?

This substance has 6 hazard statements:

  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H341: Suspected of causing genetic defects.
  • H361d: Suspected of damaging the unborn child.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of LOCTITE SF 7840?

The melting point is Not applicable, Product is a liquid and the boiling point is > 148,9 °C (> 300 °F).