NextSDS Logo
Safety Data Sheet EN

Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch
Product Form
hydraulically setting dry mortar
Chemical Name
Portland Cement Clinker; Flue Dust

Regulatory Identifiers

CAS Number
N/A
UFI Code
J600-604V-M00V-5JJH, 4800-P0U8-X00C-TW4K, DC00-60HP-700V-G7QN, RF00-Q072-J00C-4K9Q, VH00-60WF-U00U-TWVS, TM00-Q0KV-500C-F8FU, 1Q00-7098-F00U-4M1W, 9S00-Q0YN-S00A-SXMY, DV00-70P2-200U-F971, EY00-R0CF-D00A-3MT3, U110-801U-P00T-SYD5, 5410-R0R8-000A-E9Y7, N910-S041-M00A-R04C, QD10-80TE-W00T-EAQE, 1G10-S0GU-7009-2P9G, DJ10-9067-H00T-R0VJ, 3R10-90K1-400S-2Q1P, TT10-T08E-F009-Q1MR, EW10-90XT-R00S-DD6T, V020-T0N7-2008-1QSV, 0220-A0AM-C00S-Q2CX, A520-U010-P008-CDY0, X820-A0QD-Y00R-1RJ2, XA20-U0DT-9008-P344, FK20-C0G0-600R-P3VA, 1P20-V05D-H007-AFFD, NS20-C0US-T00Q-0T1F, VU20-V0J6-4007-N4MH, AX20-D07K-E00Q-AG6K, 2330-D0MD-100Q-N5CQ, D830-E005-N00P-YUHU

Identified Uses

The building material is a hydraulically setting dry mortar for the use in earthworks and civil engineering. The product is simply mixed with water and does not need any further additives. Related activities include the handling of dry materials (powder) as well as of materials mixed with water (suspension).

Manufacturers & Suppliers

H

Heidelberg Materials AG

manufacturer

Berliner Str. 6, DE-69120 Heidelberg

+49 6221 / 481 - 0

Emergency Contacts

Poison Information Center in Mainz, Germany

+49 6131 / 19 240

24 hours / 7 days

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Dam. Cat. 1 H318
STOT SE Cat. 3 H335

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H318 Causes serious eye damage.
H335 May cause respiratory irritation.

Precautionary Statements

P102 Keep out of reach of children.
P261 Avoid breathing dust.
P280 Wear protective gloves/protective clothing/eye protection.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P304 + P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER or doctor/physician.
P312 Call a POISON CENTER or doctor/physician if you feel unwell.
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.
P501 Dispose of contents/container to suitable waste collection points.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The product contains cement according to DIN EN 197 and/or DIN 1164.

Chemical Name CAS Number Concentration Hazardous
Portland cement clinker EC: 266-043-4 65997-15-1 5 - 100% Yes
Flue Dust EC: 270-659-9 68475-76-3 0.1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Seek fresh air. Dust should quickly be removed from throat and nose. Consult a physician, should symptoms such as discomfort, coughing or persistent irritation occur.

Symptoms: discomfort, coughing or persistent irritation

Skin contact

Remove dry product and rinse abundantly with water. Rinse wet product agent with plenty of water. Remove contaminated clothing, footwear, watches, etc. and clean these thoroughly before re-using them. Seek medical treatment in all cases of irritation or burns.

Symptoms: irritation on damp skin (due to sweating or humidity), skin irritation, dermatitis, or severe skin damage

Eye contact

Do not rub eyes dry, because mechanical stress may cause additional damage to the cornea. Where applicable, remove contact lenses and immediately rinse the eye, while open, under running water for at least 20 minutes in order to remove all particles. If possible, use isotonic eye-cleansing solution (0.9 % NaCl). Always consult an occupational physician or ophthalmologist.

Symptoms: serious and potentially irreversible eye damage

Ingestion

Do not induce vomiting. If the person is conscious, wash out mouth with water and give plenty of water to drink. Get immediate medical attention or contact the poison information center.

Immediate Medical Attention

Get immediate medical attention or contact the poison information center (for ingestion). Seek medical treatment in all cases of irritation or burns (for skin). Always consult an occupational physician or ophthalmologist (for eyes). Consult a physician, should symptoms such as discomfort, coughing or persistent irritation occur (for inhalation).

Medical Treatment

When contacting a physician, take this safety data sheet with you.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

The products are not flammable.

Specific hazards

The products are non-combustible and non-explosive and will not facilitate or sustain the combustion of other materials.

Instructions

No specific measures are required, as the products do not pose any fire-related hazards.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Emergency action plans are not required.

Environmental

The products should not penetrate the sewage water system, surface water or groundwater.

Cleanup methods

Dry product: Absorb spilled product and reuse, if possible. Use dry methods to clean. Wet product: Clean up wet product and place into a container. Allow material to dry and solidify before disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not eat, drink, or smoke when working. Wear dust respirator and protective goggles in dusty environment. Use protective gloves to avoid skin contact.

Storage

The products should be stored under dry (minimizing internal condensation), water-protected conditions, clean and protected from contamination.

Hygiene

Do not eat, drink, or smoke when working. Wear dust respirator and protective goggles in dusty environment. Use protective gloves to avoid skin contact.

Fire prevention

Not applicable.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Measures to prevent formation and spreading of dust, for example suitable ventilation systems and cleaning methods, which do not stir up dust.

Hands

Wear waterproof, abrasion, and alkali-resistant gloves. Leather gloves are not suitable due to their water penetrability and can release chromate-containing compounds. For handling the products, special gloves for chemicals (Cat. III) are not required. Investigations have proven that nitrile impregnated cotton gloves (layer thickness of about 0.15 mm) provide sufficient protection over a period of 480 minutes. Change soaked gloves. Have spare gloves ready.

Eyes

Use tight-fitting safety goggles according to DIN EN 166:2002 where dust is formed or in case of risk of spilling.

Respiratory

Use adequate respirator masks when there is a risk that exposure limit values are exceeded (e.g., during open handling of dry powder products). Particle-filtering half-masks of the type FFP (according to DIN EN 149:2009) must be used.

Skin/Body

Wear tight footwear and long-sleeved clothing. If contact with moist product cannot be avoided, protective clothing should also be waterproof. Take care that no moist product is running in shoes or boots from above. Observe skin protection plan. Apply skin care products, in particular after work.

Environmental

Air: Compliance with dust emission limit values in accordance with the Technical Instructions on Air Quality. Water: Do not discharge the products into groundwater or wastewater systems in larger quantities. An increase in pH value is possible through exposure. At a pH value above 9, ecotoxicological effects may occur. Water directed or drained off into the wastewater system or surface water should therefore not lead to such a relevant pH value. Wastewater and groundwater regulations must be observed. Soil: Compliance with the German Federal Soil Protection Act (BBodSchG) and the German Federal Soil Protection and Contamination Ordinance (BBodSchV). No special control measures required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
The dry product is a powdery to fine-grained inorganic material.
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
light gray to dark gray
Colour Intensity
---
Form
powdery to fine-grained
Odor
Odorless
Odor Threshold
---
Ph
11-13.5
Melting Point
> 1250 °C
Boiling Point
Not applicable
Flash Point
Does not apply to solids.
Freezing Point
> 1250 °C
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not applicable
Vapor Density
---
Relative Density
2.50-3.60 g/cm³
Bulk Density
0.8-2.2 g/cm³
Density
2.50-3.60 g/cm³
Flammability
Not applicable, as material is not combustible.
Upper Explosive Limit
Do not apply to solids.
Lower Explosive Limit
Do not apply to solids.
Explosive Limits
---
Auto Ignition Temperature
Not applicable
Decomposition Temperature
Not applicable
Solubility
in water (T = 20 °C): low (0.1-1.5 g/l)
Partition Coefficient
Not applicable
Solubility In Water
low (0.1-1.5 g/l)
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Not applicable
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable, as long as it is properly stored (see section 7). It should be kept dry. Contact with incompatible materials should be avoided.

Reactivity

The product is a hydraulic material. When mixed with water, an intended reaction takes place. As a result, the product hardens and forms a solid mass, which does not react with its environment.

Hazardous reactions

Not applicable.

Avoid

Moisture during storage can lead to lumping and loss of product quality.

Incompatible

Acids, ammonium salts, aluminum, or other base metals. Uncontrolled use of aluminum powder in wet product should be avoided as hydrogen is produced. The product dissolves in hydrofluoric acid, forming corrosive silicon tetrafluoride gas. The calcium silicates of the product may react with strongly oxidizing agents such as fluorides.

Decomposition

The product does not decompose into hazardous components.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Product exceeding the effective date of the reducing agent must be retreated or used in well-controlled, closed and fully automated processes. Unused dry product should be reused or cured with water. Moist products and sludge must be allowed to cure. Cured products should be disposed of in accordance with local official directives.

Disposal

Do not dispose of in wastewater or surface water. Dispose of cured products like concrete waste and concrete sludge.

Waste Codes

10 13 06 Other particulates and dust EWC
17 01 01 concrete EWC
10 13 14 waste concrete and concrete sludge EWC
15 01 01 paper and cardboard packaging EWC
15 01 05 composite packaging EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Within the scope of the "Agreement on Workers' Health Protection through the Good Handling and Use of Crystalline Silica and Products containing it", manufacturers of cement have committed themselves to implement "Best Practices" for safe handling (https://guide.nepsi.eu/).

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch?

The signal word is danger.

What is the physical form of Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch?

Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch is a the dry product is a powdery to fine-grained inorganic material. with light gray to dark gray color. It has odorless odor.

What is the solubility of Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch?

in water (T = 20 °C): low (0.1-1.5 g/l)

What is Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch used for?

The building material is a hydraulically setting dry mortar for the use in earthworks and civil engineering. The product is simply mixed with water and does not need any further additives. Related activities include the handling of dry materials (powder) as well as of materials mixed with water (suspension).

What are the hazard statements for Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch?

This substance has 4 hazard statements:

  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H318: Causes serious eye damage.
  • H335: May cause respiratory irritation.

What is the melting point of Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch?

The melting point is > 1250 °C and the boiling point is Not applicable.