Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Lithium Ionen Akku / Akku-Pack (LiFePO4) commonly used rechargeable li-ion battery.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Tridonic GmbH & Co KG
manufacturer
Frbergasse 15 6850 Dornbirn Austria
AT
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+43 5572 395-0
AT
Mo - Fr 8.00 - 16.00 h
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Rechargeable lithium-ion batteries are articles from which no substance is released when used properly.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Lithium Cobalt(III) Oxide EC: 235-362-0 | 12190-79-3 | 45% | โ ๏ธ Hazardous |
| Lithium Cobalt Nickel Aluminum Oxide EC: 803-110-4 | 193214-24-3 | 45% | โ ๏ธ Hazardous |
| รxido de cobalto, manganeso, nรญquel, litio (LiNiMnCoO2) EC: 620-032-4 | 346417-97-8 | 45% | โ ๏ธ Hazardous |
| carbon substance with a Community workplace exposure limit EC: 931-334-3 | 7440-44-0 | 10-30% | โ Non-hazardous |
| Lithium Manganese (III,IV) oxide EC: 601-724-5 | 12057-17-9 | 20% | โ ๏ธ Hazardous |
| Carbonzuur, dimethylester EC: 210-478-4 | 616-38-6 | 1-15% | โ ๏ธ Hazardous |
| koper (stof) EC: 231-159-6 | 7440-50-8 | 7-13% | โ ๏ธ Hazardous |
| Ethyl methyl carbonate EC: 433-480-9 | 623-53-0 | 1-10% | โ ๏ธ Hazardous |
| Ethelyne Carbonate EC: 202-510-0 | 96-49-1 | 10% | โ ๏ธ Hazardous |
| aluminium substance with a Community workplace exposure limit EC: 231-072-3 | 7429-90-5 | 3-9% | โ Non-hazardous |
| lithium fluorophosphate EC: 244-334-7 | 21324-40-3 | 0.1-5% | โ ๏ธ Hazardous |
Additional Information
For the wording of the listed hazard phrases refer to section 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Supply fresh air; consult doctor in case of complaints. In case of unconsciousness place patient stably in side position for transportation.
๐๏ธ Skin Contact
Immediately wash with water and soap and rinse thoroughly. Take off contaminated clothing and wash it before reuse. Seek medical treatment in case of complaints.
๐๏ธ Eye Contact
Rinse opened eye for several minutes under running water. Remove contact lenses, if present and easy to do. Continue rinsing. Consult an ophthalmologist or eye clinic immediately.
๐ฝ๏ธ Ingestion/Swallowing
Rinse mouth thoroughly with cold water. Do not induce vomiting. If the patient is fully conscious, give one or two glass of water to drink. Get medical attention immediately.
๐จ Immediate Medical Attention Required
Consult an ophthalmologist or eye clinic immediately (for eye contact). Get medical attention immediately (for ingestion).
Medical Treatment
Depending on the condition of the patients, the doctor must assess the symptoms and the overall general condition.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Technical measures and the use of suitable working methods take priority over the use of personal protective equipment.
๐งค Hand Protection
Not required when handling undamaged batteries. Wear protective gloves made of chloroprene or rubber if batteries are damaged. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
๐๏ธ Eye Protection
Not required when handling undamaged batteries. Wear protective goggles if batteries are damaged.
๐ท Respiratory Protection
Not required when handling undamaged batteries.
๐ฆบ Skin/Body Protection
Not required when handling undamaged batteries.
๐ Environmental Exposure Controls
Do not allow to enter sewers/ surface or ground water.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
UN3480
๐ฆ Proper Shipping Name
LITHIUM ION BATTERIES
โ ๏ธ Transport Hazard Class
9 Miscellaneous dangerous substances and articles.
๐ Packing Group
not regulated
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Lithium Ionen Akku / Akku-Pack (LiFePO4)?
The signal word for this substance is "no signal word".
What is the physical form of Lithium Ionen Akku / Akku-Pack (LiFePO4)?
Lithium Ionen Akku / Akku-Pack (LiFePO4) is a solid with various colours color. It has odourless odor.
What is Lithium Ionen Akku / Akku-Pack (LiFePO4) used for?
Rechargeable Li-ion battery
What is the melting point of Lithium Ionen Akku / Akku-Pack (LiFePO4)?
The melting point is No information available. and the boiling point is No information available..