Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Lithium Ionen Akku / Akku-Pack (LiFePO4)
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Rechargeable Li-ion battery
Manufacturers & Suppliers
Tridonic GmbH & Co KG
manufacturer
Färbergasse 15, 6850 Dornbirn, Austria
+43 5572 395-0
Emergency Contacts
Emergency Contact
+43 5572 395-0
Mo - Fr 8.00 - 16.00 h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Rechargeable lithium-ion batteries are articles from which no substance is released when used properly.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Lithium Cobalt(III) Oxide EC: 235-362-0 | 12190-79-3 | 45% | Yes |
| Lithium Cobalt Nickel Aluminum Oxide EC: 803-110-4 | 193214-24-3 | 45% | Yes |
| Lithium Nickel Manganese Cobalt Oxide EC: 620-032-4 | 346417-97-8 | 45% | Yes |
| carbon EC: 231-153-3 | 7440-44-0 | 10 - 30% | No |
| Lithium Manganese (III,IV) oxide EC: 601-724-5 | 12057-17-9 | 20% | Yes |
| dimethyl carbonate EC: 210-478-4 | 616-38-6 | 1 - 15% | Yes |
| copper EC: 231-159-6 | 7440-50-8 | 7 - 13% | Yes |
| Ethyl methyl carbonate EC: 433-480-9 | 623-53-0 | 1 - 10% | Yes |
| ethylene carbonate EC: 202-510-0 | 96-49-1 | 10% | Yes |
| aluminium EC: 231-072-3 | 7429-90-5 | 3 - 9% | No |
| Lithium hexafluorophosphate(1-) EC: 244-334-7 | 21324-40-3 | 0.1 - 5% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints. In case of unconsciousness place patient stably in side position for transportation.
Immediately wash with water and soap and rinse thoroughly. Take off contaminated clothing and wash it before reuse. Seek medical treatment in case of complaints.
Rinse opened eye for several minutes under running water. Remove contact lenses, if present and easy to do. Continue rinsing. Consult an ophthalmologist or eye clinic immediately.
Rinse mouth thoroughly with cold water. Do not induce vomiting. If the patient is fully conscious, give one or two glass of water to drink. Get medical attention immediately.
Immediate Medical Attention
Get medical attention immediately (for swallowing), consult an ophthalmologist or eye clinic immediately (for eye contact), seek medical treatment in case of complaints (for skin contact).
Medical Treatment
Depending on the condition of the patients, the doctor must assess the symptoms and the overall general condition.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
Batteries may burst at high temperatures, which may result in flammable, toxic and/or corrosive vapours. May form hydrofluoric acid if the electrolyte comes into contact with water.
Remove container from fire, if possible without risk. Cool endangered receptacles with water spray.
Firefighter Protection
Wear self-contained respiratory protective device. Wear fully protective suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Restricted access to the affected area until cleaning work is completed. Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Cover leaked material with inert absorbent material (sand or soil) and dispose of in suitable containers. Clean again.
Materials: sand or soil
Related Products
Similar products with comparable safety profiles
Lithium-Ion battery pack
---
Lithium-Ion Rechargeable Battery Pack
---
Lithium ion Rechargeable Battery Pack
---
Nickel Cadmium Akku /Akku-Pack (NiCd)
---
Li-ion Battery Pack
---
Lithium-Ionen-Batterie BP18, BP 12, BP-XS 12
---
Lithium-Ion Battery Packs (greater than 100 Watt Hours)
---
LITHIUM - ION BATTERY
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
In any case, the warnings on batteries and the instructions for use of devices and other applications must be carefully observed. Use only the recommended battery types. Never open, mechanically damage or burn the battery! Observe protective measures and safety instructions.
Store in dry conditions. Store in a cool location. Protect from heat and direct sunlight. Store in accordance with local/regional/national/international regulations. Recharge at regular intervals during prolonged storage. Store in original container. Storage at room temperature (approx. 20°C) at approx. 20~60% of the nominal capacity.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and the use of suitable working methods take priority over the use of personal protective equipment. No further data; see section 7.
Not required when handling undamaged batteries. Wear protective gloves made of chloroprene or rubber if batteries are damaged.
Not required when handling undamaged batteries. Wear protective goggles if batteries are damaged.
Not required when handling undamaged batteries.
Not required when handling undamaged batteries.
Do not allow to enter sewers/ surface or ground water.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No hazardous reactions known if stored and used as prescribed.
No further relevant information available.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not expose the rechargeable Li-Ion battery to mechanical shock. Do not disassemble, crush, short-circuit, or connect with incorrect polarity. Avoid mechanical or electrical abuse.
No further relevant information available.
No decomposition if used and stored according to specifications. With open cells there is the possibility of the release of hydrofluoric acid and carbon monoxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose only through authorized companies in accordance with local regulations.
Must not be disposed together with household garbage.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3480
- Shipping Name
- LITHIUM ION BATTERIES
- Transport Class
- 9
- Packing Group
- not regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product is an article and therefore not subject to classification and labelling according to CLP Regulation (EC) No. 1272/2008. This data sheet describes the safety requirements and is based on the safety data sheet according to REACH Regulation (EC) No. 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Lithium Ionen Akku / Akku-Pack (LiFePO4)?
The signal word is no signal word.
What is the physical form of Lithium Ionen Akku / Akku-Pack (LiFePO4)?
Lithium Ionen Akku / Akku-Pack (LiFePO4) is a solid with various colours color. It has odourless odor.
What is the solubility of Lithium Ionen Akku / Akku-Pack (LiFePO4)?
Insoluble.
What is Lithium Ionen Akku / Akku-Pack (LiFePO4) used for?
Rechargeable Li-ion battery
What is the melting point of Lithium Ionen Akku / Akku-Pack (LiFePO4)?
The melting point is No information available. and the boiling point is No information available..