Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PANAVIA 21; OXYGUARD II
- Product Code
- CA050-O
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Dental material for curing promotion and surface protection
Manufacturers & Suppliers
Kuraray Noritake Dental Inc.
manufacturer
1621 Sakazu, Kurashiki, Okayama 710-0801, Japan
Kuraray America, Inc.
distributor
33 Maiden Lane, 6th Floor, New York, NY 10038 U.S.A.
800-879-1676
www.kuraraydental.com
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| glycerol | 56-81-5 | 50 - 70% | Yes |
| Polyethyleneglycol | --- | --- | No |
| Catalysts | --- | --- | No |
| Accelerators | --- | --- | No |
| Dyes | --- | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire fighting measures that suit the environment.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Not required.
Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures required.
Store in a refrigerator (2-8 °C). Store in cool, dry conditions in well sealed receptacles. Keep receptacle tightly sealed. Protect from heat and direct sunlight.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Goggles recommended during refilling.
Not required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No decomposition if used and stored according to specifications.
No further relevant information available.
Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Smaller quantities can be disposed of with household waste.
Smaller quantities can be disposed of with household waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PANAVIA 21; OXYGUARD II?
The signal word is no signal word.
What is the physical form of PANAVIA 21; OXYGUARD II?
PANAVIA 21; OXYGUARD II is a gel appearing as gel, green with green color. It has odorless odor.
What is the solubility of PANAVIA 21; OXYGUARD II?
Fully miscible.
What is PANAVIA 21; OXYGUARD II used for?
Dental material for curing promotion and surface protection
What is the melting point of PANAVIA 21; OXYGUARD II?
The melting point is 18.2 °C (glycerol) and the boiling point is 290 °C (glycerol).