Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Neo-Clear® (xylene substitute) for microscopy
- Product Code
- 109843
Regulatory Identifiers
- CAS Number
- 64741-65-7 Check regulations →
- REACH No.
- 01-2119471991-29-XXXX
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Merck KGaA
manufacturer
64271 Darmstadt, Germany
+49 6151 72-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C10-C12,isoalkanes, < 2% aromatics EC: 265-067-2 | 64741-65-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
Take off immediately all contaminated clothing. Rinse skin with water/shower.
rinse out with plenty of water. Remove contact lenses.
caution if victim vomits. Risk of aspiration! Keep airways free. Call a physician immediately.
Symptoms: Risk of aspiration! Pulmonary failure possible after aspiration of vomit.
Immediate Medical Attention
Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Neo-Clear® (xylene substitute) for microscopy
CAS: 64741-65-7
Xylene
---
Xylene
CAS: 1330-20-7
Xylene for GC-HS, ChromSolv®
CAS: 1330-20-7
Xylene a.r.
CAS: 1330-20-7
o-Xylene for synthesis
CAS: 95-47-6
Neo-Mount® anhydrous mounting medium for microscopy
---
Tissue-Tek® Xylene (mixed isomers)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact: Glove material: Viton (R), Glove thickness: 0,70 mm, Break through time: - 480 min. splash contact: Glove material: Nitrile rubber, Glove thickness: 0,40 mm, Break through time: - 30 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 890 Vitoject (full contact), KCL 730 Camatril -Velours (splash contact).
Safety glasses
required when vapours/aerosols are generated. Recommended Filter type: Filter A-(P2). The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Flame retardant antistatic protective clothing.
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 3295
- Shipping Name
- HYDROCARBONS, LIQUID, N.O.S.
- Transport Class
- 3
- Packing Group
- III
yes
yes
no
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Neo-Clear® (xylene substitute) for microscopy?
The signal word is danger.
What is Neo-Clear® (xylene substitute) for microscopy used for?
Reagent for analysis
What are the hazard statements for Neo-Clear® (xylene substitute) for microscopy?
This substance has 3 hazard statements:
- H226: Flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H413: May cause long lasting harmful effects to aquatic life.
What is the melting point of Neo-Clear® (xylene substitute) for microscopy?
The melting point is -20 C and the boiling point is No information available..