NextSDS Logo
Safety Data Sheet EN

Neo-Clear® (xylene substitute) for microscopy

CAS 64741-65-7

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Neo-Clear® (xylene substitute) for microscopy
Product Code
1.09843

Regulatory Identifiers

CAS Number
64741-65-7 Check regulations →
REACH No.
01-2119471991-29-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

M

Millipore

M

Merck Life Science UK Limited

distributor

New Road, The Old Brickyard, GILLINGHAM, Dorset, SP8 4XT, UNITED KINGDOM

+44 (0)1747 833-000

Emergency Contacts

CHEMTREC

+44 (0)870 8200418

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Asp. Tox. Cat. 1 H304
Aquatic Chronic Cat. 4 H413

GHS Pictograms

GHS02 - Flammable

GHS02

GHS08 - Serious health hazard

GHS08

Hazard Statements

H226 Flammable liquid and vapor.
H304 May be fatal if swallowed and enters airways.
H413 May cause long lasting harmful effects to aquatic life.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P273 Avoid release to the environment.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
P331 Do NOT induce vomiting.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C10-C12,isoalkanes, < 2% aromatics 64741-65-7 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: caution if victim vomits. Keep airways free. Call a physician immediately.

Symptoms: Risk of aspiration! Pulmonary failure possible after aspiration of vomit.

Immediate Medical Attention

Call a physician immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO2) Foam Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air at elevated temperatures. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Risk of explosion.

Cleanup methods

Clean up affected area.

Materials: liquid-absorbent material (e.g. Chemizorb®)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance. For precautions see section 2.2.

Storage

Keep container tightly closed in a dry and well-ventilated place. Recommended storage temperature see product label.

Hygiene

Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Viton®, Minimum layer thickness: 0.7 mm, Break through time: 480 min, Material tested: Vitoject® (KCL 890 / Aldrich Z677698, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0.4 mm, Break through time: 30 min, Material tested: Camatril® (KCL 730 / Aldrich Z677442, Size M). This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Recommended Filter type: Filter A-(P2). The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Flame retardant antistatic protective clothing.

Environmental

Risk of explosion.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Form: liquid Color: clear
Colour
clear
Colour Intensity
---
Form
liquid
Odor
---
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
43.5 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

Vapor/air-mixtures are explosive at intense warming.

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents

Avoid

Heating.

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3295
Shipping Name
HYDROCARBONS, LIQUID, N.O.S.
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Neo-Clear® (xylene substitute) for microscopy?

The signal word is danger.

What is the physical form of Neo-Clear® (xylene substitute) for microscopy?

Neo-Clear® (xylene substitute) for microscopy is a liquid appearing as form: liquid color: clear with clear color.

What is Neo-Clear® (xylene substitute) for microscopy used for?

Reagent for analysis

What are the hazard statements for Neo-Clear® (xylene substitute) for microscopy?

This substance has 3 hazard statements:

  • H226: Flammable liquid and vapor.
  • H304: May be fatal if swallowed and enters airways.
  • H413: May cause long lasting harmful effects to aquatic life.