Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Neo-Clear® (xylene substitute) for microscopy
- Product Code
- 1.09843
Regulatory Identifiers
- CAS Number
- 64741-65-7 Check regulations →
- REACH No.
- 01-2119471991-29-XXXX
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Millipore
Merck Life Science UK Limited
distributor
New Road, The Old Brickyard, GILLINGHAM, Dorset, SP8 4XT, UNITED KINGDOM
+44 (0)1747 833-000
Emergency Contacts
CHEMTREC
+44 (0)870 8200418
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C10-C12,isoalkanes, < 2% aromatics | 64741-65-7 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: caution if victim vomits. Keep airways free. Call a physician immediately.
Symptoms: Risk of aspiration! Pulmonary failure possible after aspiration of vomit.
Immediate Medical Attention
Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2) Foam Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Vapors are heavier than air and may spread along floors. Forms explosive mixtures with air at elevated temperatures. Development of hazardous combustion gases or vapours possible in the event of fire.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate the danger area, observe emergency procedures, consult an expert.
Risk of explosion.
Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Neo-Clear® (xylene substitute) for microscopy
CAS: 64741-65-7
Neo-Clear® (xylene substitute) for microscopy
CAS: 64741-65-7
DPX new non-aqueous mounting medium for microscopy
---
DPX new non-aqueous mounting medium for microscopy
UFI: RY2Y-J5KR-299H-J1V2
Xylene
---
Xylene
CAS: 1330-20-7
Xylene for GC-HS, ChromSolv®
CAS: 1330-20-7
Xylene for analysis EMSURE® ACS,ISO,Reag.Ph Eur
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance. For precautions see section 2.2.
Keep container tightly closed in a dry and well-ventilated place. Recommended storage temperature see product label.
Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact: Material: Viton®, Minimum layer thickness: 0.7 mm, Break through time: 480 min, Material tested: Vitoject® (KCL 890 / Aldrich Z677698, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0.4 mm, Break through time: 30 min, Material tested: Camatril® (KCL 730 / Aldrich Z677442, Size M). This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Recommended Filter type: Filter A-(P2). The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Flame retardant antistatic protective clothing.
Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
Vapor/air-mixtures are explosive at intense warming.
Violent reactions possible with: Strong oxidizing agents
Heating.
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3295
- Shipping Name
- HYDROCARBONS, LIQUID, N.O.S.
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Neo-Clear® (xylene substitute) for microscopy?
The signal word is danger.
What is the physical form of Neo-Clear® (xylene substitute) for microscopy?
Neo-Clear® (xylene substitute) for microscopy is a liquid appearing as form: liquid color: clear with clear color.
What is Neo-Clear® (xylene substitute) for microscopy used for?
Reagent for analysis
What are the hazard statements for Neo-Clear® (xylene substitute) for microscopy?
This substance has 3 hazard statements:
- H226: Flammable liquid and vapor.
- H304: May be fatal if swallowed and enters airways.
- H413: May cause long lasting harmful effects to aquatic life.