NextSDS Logo
Safety Data Sheet EN

DPX new non-aqueous mounting medium for microscopy

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DPX new non-aqueous mounting medium for microscopy
Product Code
1.00579

Regulatory Identifiers

CAS Number
N/A
REACH No.
This product is a mixture. REACH Registration Number see section 3.
UFI Code
RY2Y-J5KR-299H-J1V2

Identified Uses

In vitro diagnostic reagent

Uses advised against

This product is not intended for consumer use.

Manufacturers & Suppliers

M

Merck Life Science UK Limited

manufacturer

New Road, The Old Brickyard, GILLINGHAM, Dorset, SP8 4XT, UNITED KINGDOM

+44 (0)1747 833-000

Emergency Contacts

CHEMTREC

+44 (0)870 8200418

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Acute Tox. Cat. 4 H332
Acute Tox. Cat. 4 H312
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H335
Asp. Tox. Cat. 1 H304
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapor.
H304 May be fatal if swallowed and enters airways.
H312 + H332 Harmful in contact with skin or if inhaled.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P273 Avoid release to the environment.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P331 Do NOT induce vomiting.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
m-xylene EC: 203-576-3 108-38-3 50 - 70% Yes
p-xylene EC: 203-396-5 106-42-3 10 - 20% Yes
Toluene EC: 203-625-9 108-88-3 0.25 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.

Eye contact

After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.

Ingestion

After swallowing: caution if victim vomits. Keep airways free. Call a physician immediately.

Symptoms: Risk of aspiration! Pulmonary failure possible after aspiration of vomit.

Immediate Medical Attention

Consult a physician. Call in ophthalmologist. Call a physician immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO2) Dry powder Foam

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Pay attention to flashback. Vapors are heavier than air and may spread along floors. Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.

Instructions

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

Firefighter Protection

Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains. Risk of explosion.

Cleanup methods

Take up carefully with liquid-absorbent material. Clean up affected area.

Materials: liquid-absorbent material (e.g. Chemizorb®)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.

Storage

Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition. Recommended storage temperature see product label.

Hygiene

Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact Material: Viton® Minimum layer thickness: 0.70 mm Break through time: > 480 min Material tested: Vitoject® (KCL 890 / Aldrich Z677698, Size M). Splash contact Material: Viton® Minimum layer thickness: 0.70 mm Break through time: > 480 min Material tested: Vitoject® (KCL 890 / Aldrich Z677698, Size M). This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

Flame retardant antistatic protective clothing.

Environmental

Do not let product enter drains. Risk of explosion.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
viscous liquid
Appearance
Form: viscous liquid Color: colorless
Flammability
Not applicable
Solubility
No data available
Softening Point
---
Relative Evaporation Rate
---
Vapor Density
No data available
Upper Explosive Limit
No data available
Auto Ignition Temperature
No data available
Ph
No data available
Metal Corrosion
---
Voc Content
---
Partition Coefficient
No data available
Odor
aromatic
Relative Density
No data available
Melting Point
No data available
State Under Standard Conditions
---
Solubility In Fat
---
Evaporation Rate
No data available
Properties Status
---
Boiling Point
No data available
Physical State Data
liquid
Form
viscous liquid
Flash Point
22.0 °C
Bulk Density
---
Decomposition Temperature
No data available
Crystallisation Point
---
Cloud Point
---
Colour
colorless
Dynamic Viscosity
No data available
Freezing Point
No data available
Vapor Pressure
No data available
Molecular Weight
---
Lower Explosive Limit
No data available
Solubility In Water
No data available
Colour Intensity
---
Solidification Point
---
Density
0.9068 g/cm3 at 20 °C
Explosive Limits
---
Odor Threshold
No data available
Kinematic Viscosity
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature) .

Reactivity

Vapors may form explosive mixture with air.

Hazardous reactions

Violent reactions possible with: Strong oxidizing agents, conc. sulfuric acid, Nitric acid, uranium hexafluoride, sulfur

Avoid

Warming.

Incompatible

Rubber, various plastics, Light metals

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1307
Shipping Name
XYLENES, SOLUTION
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DPX new non-aqueous mounting medium for microscopy?

The signal word is danger.

What is the physical form of DPX new non-aqueous mounting medium for microscopy?

DPX new non-aqueous mounting medium for microscopy is a viscous liquid appearing as form: viscous liquid color: colorless with colorless color. It has aromatic odor.

What is the solubility of DPX new non-aqueous mounting medium for microscopy?

No data available

What is DPX new non-aqueous mounting medium for microscopy used for?

In vitro diagnostic reagent

What are the hazard statements for DPX new non-aqueous mounting medium for microscopy?

This substance has 7 hazard statements:

  • H225: Highly flammable liquid and vapor.
  • H304: May be fatal if swallowed and enters airways.
  • H312 + H332: Harmful in contact with skin or if inhaled.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of DPX new non-aqueous mounting medium for microscopy?

The melting point is No data available and the boiling point is No data available.