Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- DPX new non-aqueous mounting medium for microscopy
- Product Code
- 1.00579
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- This product is a mixture. REACH Registration Number see section 3.
- UFI Code
- RY2Y-J5KR-299H-J1V2
Identified Uses
In vitro diagnostic reagent
Uses advised against
This product is not intended for consumer use.
Manufacturers & Suppliers
Merck Life Science UK Limited
manufacturer
New Road, The Old Brickyard, GILLINGHAM, Dorset, SP8 4XT, UNITED KINGDOM
+44 (0)1747 833-000
Emergency Contacts
CHEMTREC
+44 (0)870 8200418
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
After swallowing: caution if victim vomits. Keep airways free. Call a physician immediately.
Symptoms: Risk of aspiration! Pulmonary failure possible after aspiration of vomit.
Immediate Medical Attention
Consult a physician. Call in ophthalmologist. Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide (CO2) Dry powder Foam
For this substance/mixture no limitations of extinguishing agents are given.
Combustible. Pay attention to flashback. Vapors are heavier than air and may spread along floors. Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains. Risk of explosion.
Take up carefully with liquid-absorbent material. Clean up affected area.
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
DPX new non-aqueous mounting medium for microscopy
---
Neo-Mount® anhydrous mounting medium for microscopy
---
DPX Mountant / DPX 2nd Generation
---
NEUTRAL MOUNTING MEDIUM (DPX)
---
Entellan™ new rapid mounting medium for microscopy
---
Faramount Aqueous Mounting Medium
---
Fluorescence Mounting Medium
---
Fluorescence Mounting Medium
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture. Avoid generation of vapours/aerosols.
Keep container tightly closed in a dry and well-ventilated place. Keep away from heat and sources of ignition. Recommended storage temperature see product label.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Full contact Material: Viton® Minimum layer thickness: 0.70 mm Break through time: > 480 min Material tested: Vitoject® (KCL 890 / Aldrich Z677698, Size M). Splash contact Material: Viton® Minimum layer thickness: 0.70 mm Break through time: > 480 min Material tested: Vitoject® (KCL 890 / Aldrich Z677698, Size M). This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Recommended Filter type: Filter A (acc. to DIN 3181) for vapours of organic compounds. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Flame retardant antistatic protective clothing.
Do not let product enter drains. Risk of explosion.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature) .
Vapors may form explosive mixture with air.
Violent reactions possible with: Strong oxidizing agents, conc. sulfuric acid, Nitric acid, uranium hexafluoride, sulfur
Warming.
Rubber, various plastics, Light metals
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1307
- Shipping Name
- XYLENES, SOLUTION
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for DPX new non-aqueous mounting medium for microscopy?
The signal word is danger.
What is the physical form of DPX new non-aqueous mounting medium for microscopy?
DPX new non-aqueous mounting medium for microscopy is a viscous liquid appearing as form: viscous liquid color: colorless with colorless color. It has aromatic odor.
What is the solubility of DPX new non-aqueous mounting medium for microscopy?
No data available
What is DPX new non-aqueous mounting medium for microscopy used for?
In vitro diagnostic reagent
What are the hazard statements for DPX new non-aqueous mounting medium for microscopy?
This substance has 7 hazard statements:
- H225: Highly flammable liquid and vapor.
- H304: May be fatal if swallowed and enters airways.
- H312 + H332: Harmful in contact with skin or if inhaled.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of DPX new non-aqueous mounting medium for microscopy?
The melting point is No data available and the boiling point is No data available.