Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- F2 0.14 %; He 2.71 %; Ar 4 %; Ne 93.15 %
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial and professional. Perform risk assessment prior to use.
Uses advised against
Consumer use.
Manufacturers & Suppliers
Linde AG, Linde Gas Division
manufacturer
Seitnerstraße 70, D-82049 Pullach
Emergency Contacts
Emergency Contact
+49 (0) 89 7446 0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The concentrations of the components in the SDS header, product name on page one and in section 3.2 are in mol due to regulatory requirements. All concentrations are nominal.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Fluorine EC: 231-954-8 | 7782-41-4 | 0.14% | Yes |
| Helium EC: 231-168-5 | 7440-59-7 | 2.71% | Yes |
| Argon EC: 231-147-0 | 7440-37-1 | 4% | Yes |
| Neon EC: 231-110-9 | 7440-01-9 | 93.15% | Yes |
# This substance has workplace exposure limit(s).
Notes
PBT: persistent, bioaccumulative and toxic substance. vPvB: very persistent and very bioaccumulative substance.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Apply artificial respiration if breathing stopped.
Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.
Immediate Medical Attention
None.
Medical Treatment
None.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Material will not burn. In case of fire in the surroundings: use appropriate extinguishing agent.
None.
None.
In case of fire: Stop leak if safe to do so. Continue water spray from protected position until container stays cool. Use extinguishants to contain the fire. Isolate the source of the fire or let it burn out.
Firefighter Protection
Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA. Guideline: EN 469 Protective clothing for firefighters. Performance requirements for protective clothing for firefighting. EN 15090 Footwear for firefighters. EN 659 Protective gloves for firefighters. EN 443 Helmets for fire fighting in buildings and other structures. EN 137 Respiratory protective devices - Self-contained open-circuit compressed air breathing apparatus with full face mask - Requirements, testing, marking.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate area. Provide adequate ventilation. Prevent from entering sewers, basements and workpits, or any place where its accumulation can be dangerous.
Prevent further leakage or spillage if safe to do so.
Related Products
Similar products with comparable safety profiles
H2 1 %, Ar 99 %
---
CO2 15 %;Ar 85 %
---
Nitrogen (0.0001 - 10%), Helium (Balance)
---
O2 1 %;N2 99 %
---
O2 4%;N2 96%
---
Carbon Monoxide (0.1000% - 0.9999%), Helium (0.0001% - 80.3999%), Oxygen (19.50% - 23.50%) in Nitrogen
---
Oxygen (23.5001 - 60%), Argon (Balance)
---
Carbon Dioxide (0.00001% - 2.9999%), Helium (0.00001% - 2.00%), Hydrogen (0.00001% - 2.00%) in Air
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Only experienced and properly instructed persons should handle gases under pressure. Use only properly specified equipment. Protect containers from physical damage; do not drag, roll, slide or drop. Secure cylinders in an upright position at all times, close all valves when not in use. Suck back of water into the container must be prevented. Do not allow backfeed into the container. Avoid suckback of water, acid and alkalis. Never use direct flame or electrical heating devices to raise the pressure of a container. Leave valve protection caps in place until the container has been secured. Close container valve after each use and when empty. Never attempt to repair or modify container valves or safety relief devices. Replace valve outlet caps or plugs and container caps where supplied as soon as container is disconnected from equipment. Keep container valve outlets clean and free from contaminates. Never attempt to transfer gases from one container to another.
Keep container below 50°C in a well ventilated place. Secure cylinders in an upright position at all times.
The substance must be handled in accordance with good industrial hygiene and safety procedures. When using do not eat, drink or smoke.
Never use direct flame or electrical heating devices to raise the pressure of a container.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Consider a work permit system e.g. for maintenance activities. Ensure adequate air ventilation. Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded. Oxygen detectors should be used when asphyxiating gases may be released. Systems under pressure should be regularly checked for leakages. Preferably use permanent leak tight connections (eg. welded pipes).
Wear working gloves while handling containers Guideline: EN 388 Protective gloves against mechanical risks.
Wear eye protection to EN 166 when using gases. Guideline: EN 166 Personal Eye Protection.
Not required.
No special precautions. Wear safety shoes while handling containers Guideline: ISO 20345 Personal protective equipment - Safety footwear.
For waste disposal, see section 13 of the SDS.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No reactivity hazard other than the effects described in sub- section below.
None.
None.
No reaction with any common materials in dry or wet conditions.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
The product is reported to cause no ecological damage. Specific component data for fluorine is provided for fish, aquatic invertebrates, and algae.
12.2 Persistence and Degradability
12.3 Bioaccumulative Potential Product
The product is expected to biodegrade and is not expected to persist for long periods in an aquatic environment.
12.4 Mobility in Soil Product
The product is unlikely to cause ground or water pollution due to its high volatility. Fluorine reacts with water.
12.5 Results of PBT and vPvB assessment
The substance is not classified as PBT or vPvB.
12.6 Other Adverse Effects
No ecological damage caused by this product.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Do not discharge into any place where its accumulation could be dangerous. Vent to atmosphere in a well ventilated place.
Refer to the EIGA code of practice (Doc.30 "Disposal of Gases", downloadable at http://www.eiga.org) for more guidance on suitable disposal methods. Dispose of container via supplier only.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 1956
- Shipping Name
- COMPRESSED GAS, N.O.S.(Neon, Fluorine)
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This Safety Data Sheet has been produced to comply with Regulation (EU) 453/2010.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for F2 0.14 %; He 2.71 %; Ar 4 %; Ne 93.15 %?
The signal word is warning.
What is the physical form of F2 0.14 %; He 2.71 %; Ar 4 %; Ne 93.15 %?
F2 0.14 %; He 2.71 %; Ar 4 %; Ne 93.15 % is a gas with he: colorless f2: pale yellow ar: colorless color. It has he: odorless f2: pungent irritating odor. ar: odorless odor.
What is F2 0.14 %; He 2.71 %; Ar 4 %; Ne 93.15 % used for?
Industrial and professional. Perform risk assessment prior to use.
What are the hazard statements for F2 0.14 %; He 2.71 %; Ar 4 %; Ne 93.15 %?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of F2 0.14 %; He 2.71 %; Ar 4 %; Ne 93.15 %?
The melting point is No data available. and the boiling point is No data available..