Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ISH Peroxidase Inhibitor
- Product Code
- 07729014001
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals, Refer to product literature for further details.
Manufacturers & Suppliers
Roche Diagnostics Limited
manufacturer
Charles Avenue, Burgess Hill, RH15 9RY West Sussex, United Kingdom
+44 1444 256000
Emergency Contacts
Product Safety / Vigilance (Roche Diagnostics Ltd.)
+44 (0)808 100 1920
Product Safety / Vigilance (Roche Diagnostics Ltd.)
1800 409 564
NPIS
+44 344 892 0111
NHS Direct in Wales
111
NHS Direct in Wales
+44 845 4647
NHS 111 in England
111
NHS 24 in Scotland
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrogen Peroxide EC: 231-765-0 | 7722-84-1 | 3 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
If skin irritation persists, call a physician. If on skin, rinse well with water. If on clothes, remove clothes.
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Continue rinsing eyes during transport to hospital. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Symptoms: Small amounts splashed into eyes can cause irreversible tissue damage and blindness.
Clean mouth with water and drink afterwards plenty of water. Keep respiratory tract clear. Do NOT induce vomiting. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Take victim immediately to hospital. Rinse mouth with water.
Immediate Medical Attention
Take victim immediately to hospital.
Medical Treatment
The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
Do not allow run-off from fire fighting to enter drains or water courses.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.
Prevent product from entering drains. Prevent further leakage or spillage if safe to do so. Local authorities should be advised if significant spillages cannot be contained.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.
Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)
Related Products
Similar products with comparable safety profiles
ImmPACT™ DAB Peroxidase Substrate Kit
---
Peroxidase Blocking Solution
---
Peroxidase Blocking Solution
---
Luperox® DI, tert-Butyl peroxide
CAS: 110-05-4
Dilauroyl peroxide
CAS: 105-74-8
Sodium peroxide
CAS: 1313-60-6
Hydrogen Peroxide (30% in water)
---
Hydrogen Peroxide (30% in water)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe vapours/dust. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.
Keep container tightly closed in a dry and well-ventilated place. See label, package insert or internal guidelines.
When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No data available
In case of contact through splashing: Material: Nitrile rubber, Break through time: > 30 min, Glove thickness: > 0,11 mm. In case of full contact: Material: butyl-rubber, Break through time: > 480 min, Glove thickness: > 0,4 mm. Remarks: The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Eye wash bottle with pure water, Tightly fitting safety goggles, Wear face-shield and protective suit for abnormal processing problems.
Impervious clothing, Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No data available
Reacts with the following substances: Acids, Bases, Oxidizing agents, Reducing agents, Metals, Explosive when dry. No decomposition if stored and applied as directed.
No data available
No data available
No decomposition if stored and applied as directed. In case of fire hazardous decomposition products may be produced such as: Oxygen
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Send to a licensed waste management company. Can be disposed as waste water, when in compliance with local regulations.
Do not contaminate ponds, waterways or ditches with chemical or used container. Send to a licensed waste management company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Chemical Safety Assessments for all substances in this product are either Complete or Not applicable.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ISH Peroxidase Inhibitor?
The signal word is no signal word.
What is the physical form of ISH Peroxidase Inhibitor?
ISH Peroxidase Inhibitor is a liquid appearing as liquid with colourless color. It has slight odor.
What is the solubility of ISH Peroxidase Inhibitor?
No data available
What is ISH Peroxidase Inhibitor used for?
Laboratory chemicals, Refer to product literature for further details.
What is the melting point of ISH Peroxidase Inhibitor?
The melting point is No data available and the boiling point is No data available.