Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CLEARFIL AP-X, CLEARFIL AP-X PLT
- Product Code
- CA017-084
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Dental filling material
Manufacturers & Suppliers
Kuraray Noritake Dental Inc.
manufacturer
1621 Sakazu, Kurashiki, Okayama 710-0801, Japan
Kuraray America, Inc.
distributor
33 Maiden Lane, 6th Floor, New York, NY 10038 U.S.A.
800-879-1676
www.kuraraydental.com
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| bisphenol A diglycidylmethacrylate | 1565-94-2 | 10 - 25% | Yes |
| triethylene glycol dimethacrylate | 109-16-0 | 2.5 - 10% | Yes |
| Silanated barium glass filler | --- | --- | No |
| Silanated silica filler | --- | --- | No |
| Silanated colloidal silica | --- | --- | No |
| dl-Camphorquinone | --- | --- | No |
| Catalysts | --- | --- | No |
| Accelerators | --- | --- | No |
| Pigments | --- | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. Then consult a doctor.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Not required.
No special measures required.
Pick up mechanically.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.
Store in a cool location (2-25 °C). Keep receptacle tightly sealed. Store in cool, dry conditions in well sealed receptacles. Protect from heat and direct sunlight.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Additional information about design of technical systems: No further data; see item 7.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Goggles recommended during refilling.
Not required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No further relevant information available.
Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Smaller quantities can be disposed of with household waste.
Smaller quantities can be disposed of with household waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CLEARFIL AP-X, CLEARFIL AP-X PLT?
The signal word is warning.
What is the physical form of CLEARFIL AP-X, CLEARFIL AP-X PLT?
CLEARFIL AP-X, CLEARFIL AP-X PLT is a pasty with colored color. It has odorless odor.
What is CLEARFIL AP-X, CLEARFIL AP-X PLT used for?
Dental filling material
What are the hazard statements for CLEARFIL AP-X, CLEARFIL AP-X PLT?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
What is the melting point of CLEARFIL AP-X, CLEARFIL AP-X PLT?
The melting point is Undetermined. and the boiling point is Undetermined..