Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Coffeepure Tabs
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Espresso cleaning tablets
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Urnex Brands, Inc.
manufacturer
700 Executive Blvd., Elmsford, NY 10523 USA
+1-914-963-2042
Urnex Brands, Inc.
manufacturer
29 Harley Street, London, W1G 9QR, United Kingdom
+44 (0)20 7927 6881
Emergency Contacts
Emergency Contact
800-424-9300
Emergency Contact
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| sodium carbonate EC: 207-838-8 | 497-19-8 | 35% | Yes |
| disodium carbonate, compound with hydrogenperoxide (2:3) EC: 239-707-6 | 15630-89-4 | 22% | Yes |
| sulphamidic acid EC: 226-218-8 | 5329-14-6 | 20% | Yes |
| Polyethylene glycol EC: 500-038-2 | 25322-68-3 | 12% | Yes |
| Alcohols, C9-11, ethoxylated | 68439-46-3 | 2.5% | Yes |
For the wording of the listed risk phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately rinse with water. If skin irritation continues, consult a doctor.
Rinse opened eye for several minutes under running water. Then consult a doctor. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse out mouth and then drink plenty of water. Seek immediate medical advice.
Immediate Medical Attention
Seek immediate medical advice.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Use fire extinguishing methods suitable to surrounding conditions.
Water with full jet
Formation of toxic gases is possible during heating or in case of fire.
Cool endangered receptacles with water spray.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Dilute with plenty of water.
Pick up mechanically.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Any unavoidable deposit of dust must be regularly removed.
Store only in the original receptacle. Store under lock and key and out of the reach of children. Protect from humidity and water.
Keep respiratory protective device available.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Not necessary if room is well-ventilated.
Protective gloves. Avoid direct contact with the chemical/ the product/ the preparation by organizational measures. To avoid skin problems reduce the wearing of gloves to the required minimum. Check protective gloves prior to each use for their proper condition. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: > 480 min. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact gloves made of the following materials are suitable: Nitrile rubber, NBR. As protection from splashes gloves made of the following materials are suitable: Natural rubber, NR.
Safety glasses
Not necessary if room is well-ventilated.
Protective work clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
Reacts with strong acids and oxidizing agents. Reducing agent
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Smaller quantities can be disposed of with household waste.
Smaller quantities can be disposed of with household waste.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Void
- Shipping Name
- Void
- Transport Class
- Void
- Packing Group
- Void
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No further relevant information available.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Coffeepure Tabs?
The signal word is warning.
What is the physical form of Coffeepure Tabs?
Coffeepure Tabs is a solid appearing as form: solid, colour: white with white color. It has characteristic odor.
What is the solubility of Coffeepure Tabs?
Soluble.
What is Coffeepure Tabs used for?
Espresso cleaning tablets
What are the hazard statements for Coffeepure Tabs?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
What is the melting point of Coffeepure Tabs?