Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Security Check Paint Marker
- Product Form
- Mixture
- Synonyms
- Security Check Paint Marker - Black, Blue, Green, Red, White, Yellow, Orange, Purple
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Marking.
Uses advised against
No additional information available
Manufacturers & Suppliers
LA-CO Industries Europe S.A.S.
manufacturer
Parc Industriel de la Plaine de l'Ain - Allée des Combes. 01150.BLYES.France.
+33 (0)4 74 46 23 23
http://www.markal.com
Emergency Contacts
CHEMTREC- U.S.
1-800-424-9300
CHEMTREC
+1-703-527-3887
Vergiftungsinformationszentrale (Poisons Information Centre)
+43 1 406 43 43
The Belarus Republican Poisons Centre
+375 (0)17 201 9158
Centre Anti-Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid
+32 70 245 245
Национален токсикологичен информационен център National Clinical Toxicology Centre, Emergency Medical Institute "Pirogov"
+359 2 9154 409
Poisons Control Centre Institute of Medical Research & Occupational Health
+385 1 234 8342
Toxikologické informační středisko Clinic For Occupational Medicine, 1st Medical Faculty, Charles University
+42 2 2491 9293
Toxikologické informační středisko Clinic For Occupational Medicine, 1st Medical Faculty, Charles University
+42 2 2491 5402
Giftlinjen Bispetjerg Hospital
+45 82 12 12 12
Giftlinjen Bispetjerg Hospital
+45 35 31 55 55
Mürgistusteabekeskus
+372 626 93 90
Myrkytystietokeskus
+358 9 471 977
ORFILA
+33 1 45 42 59 59
Berliner Betrieb für Zentrale Gesundheitliche Aufgaben
+49 30 19240
Informations und Beratungszentrum für Vergiftungsfälle
+49 6841 19240
Beratungstelle bei Vergiftungen, Klinische Toxikologie und Beratungsstelle bei Vergiftungen
+49 6131 19240
Poisons Information Centre
+30 10 779 3777
Országos Kémiai Biztonsági Intézet (National Institute of Chemical Safety) Egészségügyi Toxikológiai Tájékoztató Szolgálat (Health Toxicological Information Service)
+36 80 20 11 99
Eitrunarmiðstöðin
+354 543 22 22
National Poisons Information Centre
+353 1 809 2166
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Butyl acetate EC: 204-658-1 | 123-86-4 | 25 - 55% | No |
| calcium carbonate EC: 207-439-9 | 471-34-1 | 30 - 40% | No |
| titanium dioxide EC: 236-675-5 | 13463-67-7 | 7% | No |
| Silicon dioxide (cristobalite) EC: 238-878-4 | 14808-60-7 | 0.5 - 1.5% | No |
| Carbon black EC: 215-609-9 | 1333-86-4 | 1% | No |
| Magnesium oxide EC: 215-171-9 | 1309-48-4 | 0.7% | No |
| Benzaldehyde EC: 202-860-4 | 100-52-7 | 0.5% | No |
| 2-methoxy-1-methylethyl acetate EC: 203-603-9 | 108-65-6 | 0.5% | No |
| Aluminum oxide EC: 215-691-6 | 1344-28-1 | 0.1% | No |
| Xylene EC: 215-535-7 | 1330-20-7 | 0.1% | No |
| D-Limonène EC: 227-813-5 | 5989-27-5 | 0.1% | No |
| Iron oxide red EC: 215-168-2 | 1309-37-1 | 0.1% | No |
| 1-Butanol EC: 200-751-6 | 71-36-3 | 0.1% | No |
Notes
Only component with health hazards above the applicable thresholds and/or Exposure Limit values are shown.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell.
Symptoms: May cause drowsiness or dizziness. Inhalation of vapours may cause respiratory irritation.
Take off immediately all contaminated clothing. Rinse skin with water/shower.
Symptoms: Repeated exposure may cause skin dryness or cracking.
In case of contact, immediately flush eyes with plenty of water.
Get medical advice/attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing media appropriate for surrounding fire.
None known.
Flammable liquid and vapour. Burning produces irritating, toxic and noxious fumes. May form flammable/explosive vapour-air mixture.
Use water spray or fog for cooling exposed containers.
Firefighter Protection
Wear a self contained breathing apparatus. Wear fire/flame resistant/retardant clothing. EN469.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Stop leak if safe to do so. Ventilate area.
Avoid release to the environment.
Absorb and/or contain spill with inert material, then place in suitable container. Following recovery, flush area with water. Clean surface thoroughly to remove residual contamination.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No open flames. No smoking. Take precautionary measures against static discharge. Use only non-sparking tools. Avoid all eye and skin contact and do not breathe vapour and mist. Use only outdoors or in a well-ventilated area.
Keep container tightly closed. Store in dry, cool, well-ventilated area. Keep out of direct sunlight. Keep out of reach of children.
Always wash your hands immediately after handling this product, and once again before leaving the workplace. Do not eat, drink or smoke when using this product.
No open flames. No smoking. Take precautionary measures against static discharge. Use only non-sparking tools. Keep away from heat, sparks and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation of the work station.
None under normal use.
None under normal use
In case of inadequate ventilation wear respiratory protection. Wear appropriate mask. EN 12083
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Flammable liquid and vapour. May form flammable/explosive vapour-air mixture.
No dangerous reactions known.
Hazardous polymerization will not occur.
Open flame. Overheating. Direct sunlight. Heat. Sparks.
Strong bases. Strong oxidizers. Strong acids.
May release flammable gases. Burning produces irritating, toxic and noxious fumes.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose in a safe manner in accordance with local/national regulations.
Dispose in a safe manner in accordance with local/national regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Miscibility with water depends upon the composition.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Security Check Paint Marker known by?
Security Check Paint Marker is also known as: Security Check Paint Marker - Black, Blue, Green, Red, White, Yellow, Orange, Purple
What is the hazard signal word for Security Check Paint Marker?
The signal word is warning.
What is the physical form of Security Check Paint Marker?
Security Check Paint Marker is a liquid appearing as solid marker containing liquid colored paint. with variable. color. It has solvent. odor.
What is the solubility of Security Check Paint Marker?
insoluble in water.
What is Security Check Paint Marker used for?
Marking.
What are the hazard statements for Security Check Paint Marker?
This substance has 2 hazard statements:
- H226: Flammable liquid and vapour.
- H336: May cause drowsiness or dizziness.
What is the melting point of Security Check Paint Marker?
The melting point is No data available and the boiling point is > 35 °C.