NextSDS Logo
In

Interflon Grease MP00

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Interflon Grease MP00

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial use, lubricant

Overview

Interflon Grease MP00 is a liquid, yellowish brown substance commonly used industrial use, lubricant.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Interflon BV company logo - Safety Data Sheet supplier organization

Interflon BV

manufacturer

๐Ÿ“

Belder 47 4704 RK Roosendaal Netherlands

๐ŸŒ

NL

๐Ÿ“ž

+31 (0)165 553911

๐ŸŒ www.Interflon.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+31 (0)165 55 39 11

๐ŸŒ

NL

๐Ÿ•’

Monday to Friday from 8:30am to 17:00pm

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mixture of mineral oils, thickener, additives and MicPol

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Dilithiumazelaat
EC: 254-184-4
38900-29-7 1-2.5% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathing is irregular or stopped, immediately seek medical assistance and start first aid actions. Provide fresh air.

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses, if present and easy to do. Continue rinsing. Rinse cautiously with water for several minutes.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth with water (only if the person is conscious). Do NOT induce vomiting. Get medical advice/attention if you feel unwell.

๐Ÿšจ Immediate Medical Attention Required

If breathing is irregular or stopped, immediately seek medical assistance.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquid, yellowish brown
๐ŸŽจ Colour
yellowish brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Like oil
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
not determined
๐ŸงŠ Melting Point
not determined
Critical Property
๐Ÿ’จ Boiling Point
not determined
Critical Property
๐Ÿ”ฅ Flash Point
>250 C
Critical Property
๐Ÿ“Š Freezing Point
not determined
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined
๐Ÿ’จ Vapor Pressure
not determined
๐Ÿ“Š Vapor Density
this information is not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,9 [g] / cm at 20 C
Critical Property
๐Ÿ”ฅ Flammability
not relevant, (fluid)
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
not determined
๐Ÿ“Š Partition Coefficient
this information is not available
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0 % by mass of the contents are flammable
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Not applicable.

๐Ÿ‘๏ธ Eye Protection

Use protective eyewear to guard against splash of liquids.

๐Ÿ˜ท Respiratory Protection

Not required.

๐Ÿฆบ Skin/Body Protection

Take recovery periods for skin regeneration. Preventive skin protection (barrier creams/ointments) is recommended. Wash hands thoroughly after handling.

๐ŸŒ Environmental Exposure Controls

Use appropriate container to avoid environmental contamination. Keep away from drains, surface and ground water.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Interflon Grease MP00?

The signal word for this substance is "no signal word".

What is the physical form of Interflon Grease MP00?

Interflon Grease MP00 is a liquid appearing as liquid, yellowish brown with yellowish brown color. It has like oil odor.

What is the solubility of Interflon Grease MP00?

not determined

What is Interflon Grease MP00 used for?

Industrial use, lubricant

What is the melting point of Interflon Grease MP00?

The melting point is not determined and the boiling point is not determined.