01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Shell Corena S2 P 100
Product Code
001D7779

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Compressor oil.

Manufacturers & Suppliers

V

Viva Energy Australia Pty Ltd

undefined

720 Bourke Street Docklands Victoria 3008 Australia

+61 (0)3 8823 4444

Emergency Contacts

Emergency Contact

1800 651 818

POISONS INFORMATION CENTRE

13 11 26

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture

Highly refined mineral oils and additives. The highly refined mineral oil contains <3% (w/w) DMSOextract, according to IP346. Classification based on DMSO extract content < 3% (Regulation (EC) 1272/2008, Annex VI, Part 3, Note L).

Chemical Name CAS Number Concentration Hazardous
Interchangeable low viscosity base oil (<20,5 cSt @40C) * --- 90% Yes
Alkylphenol EC: 204-279-1 118-82-1 --- Yes

Notes

- contains one or more of the following CAS-numbers: 6474253-6, 64742-54-7, 64742-55-8, 64742-56-9, 64742-65-0, 68037-01-4, 72623-86-0, 72623-87-1, 8042-47-5, 848301-69-9, 68649-12-7, 151006-60-9, 163149-28-8, 64741-88-4, 64741-89-5.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No treatment necessary under normal conditions of use. If symptoms persist, obtain medical advice.

Skin contact

Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention.

Symptoms: Oil acne/folliculitis signs and symptoms may include formation of black pustules and spots on the skin of exposed areas. If persistent irritation occurs.

Eye contact

Flush eye with copious quantities of water. Remove contact lenses, if present and easy to do. Continue rinsing. If persistent irritation occurs, obtain medical attention.

Ingestion

In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.

Symptoms: Ingestion may result in nausea, vomiting and/or diarrhoea.

Medical Treatment

Treat symptomatically.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Select controls based on a risk assessment of local circumstances. Appropriate measures include: Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated.

Hands

Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model.

Eyes

If material is handled such that it could be splashed into eyes, protective eyewear is recommended.

Respiratory

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for the combination of organic gases and vapours and particles [Type A/Type P boiling point >65C (149F)].

Skin/Body

Skin protection is not ordinarily required beyond standard work clothes. It is good practice to wear chemical resistant gloves.

Environmental

Take appropriate measures to fulfill the requirements of relevant environmental protection legislation. Avoid contamination of the environment by following advice given in Section 6. If necessary, prevent undissolved material from being discharged to waste water. Waste water should be treated in a municipal or industrial waste water treatment plant before discharge to surface water. Local guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing vapour.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Decomposition Temperature
Data not available
Odor
Data not available
Explosive Limits
---
Solidification Point
---
Colour
light brown
Melting Point
Data not available
Properties Status
---
Vapor Pressure
< 0.5 Pa (20 C / 68 F)
Density
899 kg/m3 (15.0 C / 59.0 F)
Crystallisation Point
---
Boiling Point
> 280 C / 536 F
Metal Corrosion
---
Vapor Density
---
Voc Content
---
Softening Point
---
Molecular Weight
---
Physical State
Liquid at room temperature.
Lower Explosive Limit
Typical 1 %(V)
Cloud Point
---
Ph
Not applicable
Relative Evaporation Rate
---
Auto Ignition Temperature
> 320 C / 608 F
State Under Standard Conditions
---
Solubility In Fat
---
Odor Threshold
Data not available
Colour Intensity
---
Relative Density
0.899 (15 C / 59 F)
Physical State Data
liquid
Flammability
Not classified as flammable but will burn.
Solubility
---
Kinematic Viscosity
100 mm2/s (40.0 C / 104.0 F) 9.2 mm2/s (100 C / 212 F)
Flash Point
>= 205 C / >= 401 F
Upper Explosive Limit
Typical 10 %(V)
Partition Coefficient
log Pow: > 6
Form
---
Appearance
Liquid at room temperature.
Dynamic Viscosity
Data not available
Solubility In Water
negligible
Evaporation Rate
Data not available
Bulk Density
---
Freezing Point
-33 C / -27 F
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Shell Corena S2 P 100?

The signal word is no signal word.

What is the physical form of Shell Corena S2 P 100?

Shell Corena S2 P 100 is a liquid at room temperature. appearing as liquid at room temperature. with light brown color. It has data not available odor.

What is Shell Corena S2 P 100 used for?

Compressor oil.

What is the melting point of Shell Corena S2 P 100?

The melting point is Data not available and the boiling point is > 280 C / 536 F.