Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SHELL TELLUS S3 M 100
- Product Code
- 16080845, 16080851
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hydraulic oil.
Uses advised against
No specific uses advised against are identified. (*)
Manufacturers & Suppliers
Struers ApS
manufacturer
Pederstrupvej 84, DK-2750 Ballerup
+45 44 600 800
DHI
Emergency Contacts
National Capital Poison Center
1-800-222-1222
Infotrac
1-800-535-5053
Struers US
1-440-871-0071
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The product contains: Highly refined mineral oil and additives. DMSO < 3% (IP 346)
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Highly refined mineral oil and additives | --- | --- | No |
| DMSO | --- | 3% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move into fresh air and keep at rest. Seek medical attention and bring along these instructions.
Symptoms: persistent throat irritation or coughing
Remove contaminated clothing immediately and wash skin with soap and water. Seek medical attention and bring along these instructions.
Symptoms: rashes, wounds or other skin disorders
Immediately flush with plenty of water for at least 15 minutes. Remove any contact lenses and open eyelids widely. Seek medical attention and bring along these instructions.
Symptoms: irritation
Immediately rinse mouth and drink plenty of water. Keep person under observation. Do not induce vomiting. Seek hospital and bring these instructions.
Symptoms: uncomfortable
Immediate Medical Attention
Seek medical attention and bring along these instructions if symptoms persist or if the person becomes uncomfortable.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire-extinguishing media appropriate for surrounding materials.
Do not use water jet as an extinguisher, as this will spread the fire.
When heated and in case of fire, toxic vapors/gases may be formed.
Firefighter Protection
Selection of respiratory protection for fire fighting: follow the general fire precautions indicated in the workplace.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For non-emergency personnel: Avoid inhalation of oil mist and contact with skin and eyes. In case of spills, beware of slippery floors and surfaces. For personal protection, see section 8. For emergency responders: No specific recommendations. For personal protection, see section 8.
Do not discharge into drains, water courses or onto the ground.
Absorb spillage with oil-absorbing material.
Materials: oil-absorbing material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid inhalation of oil mist and contact with skin and eyes. Always remove oil with soap and water or skin cleaning agent, never use organic solvents. Do not use oil-contaminated clothing or shoes, and do not put rags moistened with oil into pockets. Observe good chemical hygiene practices.
Store in tightly closed original container in a dry, cool and well-ventilated place.
Observe good chemical hygiene practices.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation. Observe Occupational Exposure Limits and minimize the risk of inhalation of vapors and oil mist. Provide access to washing facilities incl. soap, skin cleanser and fatty cream.
Risk of contact: Wear protective gloves. Nitrile gloves are recommended. The most suitable glove must be chosen in consultation with the gloves supplier, who can inform about the breakthrough time of the glove material. Breakthrough time: >480 min Thickness: >0.35 mm (*)
Risk of contact: Wear goggles/face shield.
In case of inadequate ventilation or risk of inhalation of oil mist, suitable respiratory equipment with combination filter (type A2/P3) can be used.
No special precautions.
Not available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal temperature conditions.
None known.
None known.
Extremes of temperatures. Direct sunlight. Heat, sparks, flames.
Strong oxidizing substances.
None known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SHELL TELLUS S3 M 100?
The signal word is no signal word.
What is the physical form of SHELL TELLUS S3 M 100?
SHELL TELLUS S3 M 100 is a liquid. with amber. color. It has hydrocarbon. odor.
What is the solubility of SHELL TELLUS S3 M 100?
insoluble in water
What is SHELL TELLUS S3 M 100 used for?
Hydraulic oil.
What is the melting point of SHELL TELLUS S3 M 100?
The melting point is Not available. and the boiling point is >536°F.