Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Shell Corena Oil D 46
- Product Code
- 001A9777
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Compressor oil.
Manufacturers & Suppliers
Shell Deutschland Oil GmbH
manufacturer
Suhrenkamp 71-77, D-22335 Hamburg
(+49) 40 6324-6255
Emergency Contacts
Emergency Contact
+49 (0)40 6324-5110
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Highly refined mineral oils and additives.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Calcium dinonyInaphthalene sulphonate EC: 260-991-2 | 57855-77-3 | 0.1 - 0.5% | Yes |
The highly refined mineral oil contains <3% (w/w) DMSO-extract, according to IP346. Refer to chapter 16 for full text of EC R-phrases.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention.
Flush eye with copious quantities of water. If persistent irritation occurs, obtain medical attention.
In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only.
Do not use water in a jet.
Hazardous combustion products may include: A complex mixture of airborne solid and liquid particulates and gases (smoke). Carbon monoxide. Unidentified organic and inorganic compounds.
Firefighter Protection
Proper protective equipment including breathing apparatus must be worn when approaching a fire in a confined space.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with spilled or released material. Avoid contact with skin and eyes.
Use appropriate containment to avoid environmental contamination. Prevent from spreading or entering drains, ditches or rivers by using sand, earth, or other appropriate barriers.
Slippery when spilt. Avoid accidents, clean up immediately. Reclaim liquid directly or in an absorbent. Soak up residue with an absorbent such as clay, sand or other suitable material and dispose of properly.
Materials: clay, sand or other suitable material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid prolonged or repeated contact with skin. Avoid inhaling vapour and/or mists. When handling product in drums, safety footwear should be worn and proper handling equipment should be used.
Keep container tightly closed and in a cool, well-ventilated place. Use properly labelled and closeable containers.
Avoid prolonged or repeated contact with skin.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated.
Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection: PVC, neoprene or nitrile rubber gloves. Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, glove thickness, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced.
Wear safety glasses or full face shield if splashes are likely to occur. Approved to EU Standard EN166.
No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [boiling point >65 °C (149 °F)] meeting EN141.
Skin protection not ordinarily required beyond standard issue work clothes.
Minimise release to the environment. An environmental assessment must be made to ensure compliance with local environmental legislation.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable.
Extremes of temperature and direct sunlight.
Strong oxidising agents.
Hazardous decomposition products are not expected to form during normal storage.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Recover or recycle if possible.
It is the responsibility of the waste generator to determine the toxicity and physical properties of the material generated to determine the proper waste classification and disposal methods in compliance with applicable regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Not classified as dangerous under EC criteria.
Sensitiser not sufficient to classify: Contains calcium sulphonate. May produce an allergic reaction.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Shell Corena Oil D 46?
The signal word is no signal word.
What is the physical form of Shell Corena Oil D 46?
Shell Corena Oil D 46 is a clear light brown. liquid. appearing as clear light brown. with light brown color. It has slight hydrocarbon. odor.
What is Shell Corena Oil D 46 used for?
Compressor oil.