NextSDS Logo
Safety Data Sheet EN

SCL-500

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SCL-500
Product Code
SCL-500

Regulatory Identifiers

CAS Number
N/A
UFI Code
ED40-R0NP-U009-D21N

Identified Uses

Neutralising fluid for neutralising electrolytic cleaning fluids and degreasing stainless steel surfaces.

Uses advised against

Do not use for purposes other than those listed.

Manufacturers & Suppliers

Core Industrial B.V. logo

Core Industrial B.V.

manufacturer

Oud Camp 22, 3155 DL Maasland, Nederland

+31886972520

https://www.core-industrial.nl

Emergency Contacts

Emergency Contact

+31886972520

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319
Skin Irrit. Cat. 2 H315

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H319 Causes serious eye irritation.

Precautionary Statements

P280 Wear protective gloves / protective clothing / eye protection / face protection.
P337 + P313 If eye irritation persists: Get medical advice / attention.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture
Chemical Name CAS Number Concentration Hazardous
BUTYLGLYKOL EC: 203-905-0 111-76-2 1 - 3% Yes
NATRIUMHYDROXID EC: 215-185-5 1310-73-2 0.1 - 1% Yes

Notes

The full wording of hazard (H) phrases is given in section 16 of the sheet.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to open air. In the event of breathing difficulties, get medical advice/attention immediately.

Symptoms: breathing difficulties

Skin contact

Remove contaminated clothing. Wash immediately with plenty of water. If irritation persists, get medical advice/attention. Wash contaminated clothing before using it again.

Symptoms: irritation

Eye contact

Remove contact lenses, if present. Wash immediately with plenty of water for at least 15 minutes, opening the eyelids fully. If problem persists, seek medical advice.

Ingestion

Get medical advice/attention. Induce vomiting only if indicated by the doctor. Never give anything by mouth to an unconscious person, unless authorised by a doctor.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Make sure that the workplace is well aired through effective local aspiration.

Hands

Protect hands with category III work gloves (see standard EN 374). The following should be considered when choosing work glove material: compatibility, degradation, failure time and permeability. The work gloves' resistance to chemical agents should be checked before use, as it can be unpredictable. The gloves' wear time depends on the duration and type of use.

Eyes

Wear airtight protective goggles (see standard EN 166).

Respiratory

If the threshold value (e.g. TLV-TWA) is exceeded for the substance or one of the substances present in the product, use a mask with a type A filter whose class (1, 2 or 3) must be chosen according to the limit of use concentration. (see standard EN 14387). In the presence of gases or vapours of various kinds and/or gases or vapours containing particulate (aerosol sprays, fumes, mists, etc.) combined filters are required. Respiratory protection devices must be used if the technical measures adopted are not suitable for restricting the worker's exposure to the threshold values considered. The protection provided by masks is in any case limited. If the substance considered is odourless or its olfactory threshold is higher than the corresponding TLV-TWA and in the case of an emergency, wear open-circuit compressed air breathing apparatus (in compliance with standard EN 137) or external air-intake breathing apparatus (in compliance with standard EN 138). For a correct choice of respiratory protection device, see standard EN 529.

Skin/Body

Wear category II professional long-sleeved overalls and safety footwear (see Regulation 2016/425 and standard EN ISO 20344).

Environmental

The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with environmental standards.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
colourless
Colour Intensity
---
Form
---
Odor
typical
Odor Threshold
Not available
Ph
10,9 (sol. 1%)
Melting Point
Not available
Boiling Point
100C
Flash Point
nonflammable
Freezing Point
Not available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available
Vapor Pressure
Not available
Vapor Density
Not available
Relative Density
1 kg/dm3
Bulk Density
---
Density
---
Flammability
Not available
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
---
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
completely soluble in water
Partition Coefficient
Not available
Solubility In Water
completely soluble in water
Solubility In Fat
---
Molecular Weight
---
Voc Content
5.00 %
Metal Corrosion
---
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SCL-500?

The signal word is warning.

What is the physical form of SCL-500?

SCL-500 is a liquid appearing as liquid with colourless color. It has typical odor.

What is the solubility of SCL-500?

completely soluble in water

What is SCL-500 used for?

Neutralising fluid for neutralising electrolytic cleaning fluids and degreasing stainless steel surfaces.

What are the hazard statements for SCL-500?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

What is the melting point of SCL-500?

The melting point is Not available and the boiling point is 100C.