NextSDS Logo
Safety Data Sheet EN

MONOLUX-500

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MONOLUX-500
Product Form
Self-supporting calcium silicate board

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Fire protection in buildings.

Manufacturers & Suppliers

P

Promat International NV

manufacturer

Bormstraat 24, 2830 Tisselt BELGIUM

Emergency Contacts

Emergency Contact

+32 15 71 81 00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

This article is classified as not hazardous. This product is a manufactured article, not a substance nor a preparation.

Chemical Name CAS Number Concentration Hazardous
Cellulose fibers EC: 265-995-8 65996-61-4 --- No
Quartz (SiO2) EC: 238-878-4 14808-60-7 --- No
Crystalline calcium silicate hydrate EC: 215-710-8 1344-95-2 --- No
Vermiculite 1318-00-9 --- No
Wollastonite EC: 237-772-5 13983-17-0 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air and drink water.

Skin contact

Rinse the skin with water.

Eye contact

Do not rub the eye. Rinse the eye out with plenty of clean water for at least 15 minutes. If eye irritation or inflammation persists, seek medical advice.

Ingestion

Drink water.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

All extinguishing media can be used.

Specific hazards

Nothing to report.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Minimize generation of dust. Avoid breathing dusts. Avoid eye and skin contact. Use recommended respiratory protection.

Small spill

Shovel up small pieces. Dampen down any dust before putting into appropriate skips.

Environmental

Prevent spread of dust.

Cleanup methods

Shovel up small pieces. Dampen down any dust before putting into appropriate skips.

Materials: appropriate skips

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Dust, generated during machining and processing must be exhausted and the regulatory occupational exposure limits (workplace exposure limits in UK) for total and respirable dust and respirable quartz dust must be respected. Use always respiratory protective equipment when exposures are likely or can be foreseen to exceed the Occupational Exposure Limits or Workplace Exposure Limits in UK (refer to local regulations). Collect dust with a vacuum cleaner or soak with water before sweeping up.

Storage

Store in dry, covered and frost proof area.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure vacuum dust exhaust with correct filter when using motorised machining tools.

Hands

Use working clothes and gloves to protect against mechanical injury and direct skin contact.

Eyes

Use safety glasses whenever tools are used and dusts are produced.

Respiratory

Avoid breathing dusts. Use appropriate respiratory equipment when exposures are likely or can be foreseen to exceed the Occupational Exposure Limits or Workplace Exposure Limits for the UK (e.g. for exposures up to 10 times the OEL (WEL) use at least a P2 type duct mask. For higher exposure, use a P3 type mask).

Skin/Body

Use working clothes and gloves to protect against mechanical injury and direct skin contact.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solidification Point
---
Dynamic Viscosity
---
Vapor Pressure
---
Odor Threshold
---
Physical State
Solid
Cloud Point
---
Softening Point
---
Vapor Density
---
Evaporation Rate
---
Solubility
---
Colour Intensity
---
Upper Explosive Limit
---
Solubility In Water
Insoluble
Solubility In Fat
---
Voc Content
---
Melting Point
---
Freezing Point
---
Boiling Point
---
Relative Density
---
Form
---
Density
ca. 770 kg/m3
Ph
ca. 10
Partition Coefficient
---
State Under Standard Conditions
---
Odor
---
Explosive Limits
---
Flammability
Non flammable
Bulk Density
---
Physical State Data
solid
Molecular Weight
---
Metal Corrosion
---
Auto Ignition Temperature
---
Appearance
Board (solid)
Relative Evaporation Rate
---
Kinematic Viscosity
---
Crystallisation Point
---
Properties Status
---
Lower Explosive Limit
---
Decomposition Temperature
---
Flash Point
---
Colour
Off-white
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions of storage, handling and use.

Reactivity

Stable under normal conditions.

Hazardous reactions

None.

Avoid

None known.

Incompatible

Strong acids.

Decomposition

None known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Handle as construction industry waste.

Disposal

Dispose in a safe manner in accordance with local/national regulations.

Waste Codes

170107 European Waste Catalogue EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Symbol(s): None. R Phrase(s): None. S Phrase(s): None.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MONOLUX-500?

The signal word is no signal word.

What is the physical form of MONOLUX-500?

MONOLUX-500 is a solid appearing as board (solid) with off-white color.

What is MONOLUX-500 used for?

Fire protection in buildings.