Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SCL-255
- Product Code
- SCL-255
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Electrolyte to remove weld discoloration, clean, polish and passivate stainless steel with an electrolytic weld cleaner.
Uses advised against
Do not use for purposes other than those listed.
Manufacturers & Suppliers
Core Industrial B.V.
national supplier
Oud Camp 22, 3155 DL Maasland
http://www.core-industrial.nl
Emergency Contacts
Emergency Contact
+31886972520
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Contains: PHOSPHORIC ACID
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| PHOSPHORIC ACID EC: 231-633-2 | 7664-38-2 | 70 - 80% | Yes |
Notes
The full wording of hazard (H) phrases is given in section 16 of the sheet.
First Aid Measures
Emergency procedures for chemical exposure incidents
Get medical advice/attention immediately. Remove victim to fresh air, away from the accident scene. If the subject stops breathing, administer artificial respiration. Take suitable precautions for rescue workers.
Remove contaminated clothing. Rinse skin with a shower immediately. Get medical advice/attention.
Remove contact lenses, if present. Wash immediately with plenty of water for at least 30-60 minutes, opening the eyelids fully. Get medical advice/attention.
Have the subject drink as much water as possible. Get medical advice/attention. Do not induce vomiting unless explicitly authorised by a doctor.
Immediate Medical Attention
Get medical advice/attention.
Medical Treatment
Information not available
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
carbon dioxide, foam, powder and water spray.
None in particular.
Do not breathe combustion products.
Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health.
Firefighter Protection
Always wear full fire prevention gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Block the leakage if there is no hazard.
The product must not penetrate into the sewer system or come into contact with surface water or ground water.
Absorb the remainder with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
SCL-500
---
ECL 215
---
CERECLOR™ S40/S45/S50 /S52/S52HV/ S52SS/51L/S54/S55/S56/S58/S60/S63
---
CERECLOR™ S40 / S45 / S50 / S52 / S52HV / S52SS / 51L / S54 / S55 / S56 / S58 / S60 / S63
---
CERECLOR™ S40/S45/S45SS/S50/S52/S52HV/S52SS/51L/S54/S55/S56/S58/S60/S63
CAS: 085535-85-9
SAS591
---
SU5614
CAS: 1055412-47-9
LCH 05
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Before handling the product, consult all the other sections of this material safety data sheet. Avoid leakage of the product into the environment. Do not eat, drink or smoke during use. Remove any contaminated clothes and personal protective equipment before entering places in which people eat.
Store only in the original container. Store the containers sealed, in a well ventilated place, away from direct sunlight.
Do not eat, drink or smoke during use. Remove any contaminated clothes and personal protective equipment before entering places in which people eat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
As the use of adequate technical equipment must always take priority over personal protective equipment, make sure that the workplace is well aired through effective local aspiration.
Protect hands with category III work gloves (see standard EN 374). The following should be considered when choosing work glove material: compatibility, degradation, failure time and permeability. The work gloves' resistance to chemical agents should be checked before use, as it can be unpredictable. The gloves' wear time depends on the duration and type of use.
Wear a hood visor or protective visor combined with airtight goggles (see standard EN 166).
If the threshold value (e.g. TLV-TWA) is exceeded for the substance or one of the substances present in the product, use a mask with a type B filter whose class (1, 2 or 3) must be chosen according to the limit of use concentration. (see standard EN 14387). In the presence of gases or vapours of various kinds and/or gases or vapours containing particulate (aerosol sprays, fumes, mists, etc.) combined filters are required. Respiratory protection devices must be used if the technical measures adopted are not suitable for restricting the worker's exposure to the threshold values considered. The protection provided by masks is in any case limited. If the substance considered is odourless or its olfactory threshold is higher than the corresponding TLV-TWA and in the case of an emergency, wear open-circuit compressed air breathing apparatus (in compliance with standard EN 137) or external air-intake breathing apparatus (in compliance with standard EN 138). For a correct choice of respiratory protection device, see standard EN 529.
Wear category III professional long-sleeved overalls and safety footwear (see Regulation 2016/425 and standard EN ISO 20344). Wash body with soap and water after removing protective clothing.
The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with environmental standards.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable in normal conditions of use and storage.
There are no particular risks of reaction with other substances in normal conditions of use. PHOSPHORIC ACID: Decomposes at temperatures above 200°C/392°F.
No hazardous reactions are foreseeable in normal conditions of use and storage. PHOSPHORIC ACID: Risk of explosion on contact with: nitromethane. May react dangerously with: alkalis, sodium borohydride.
None in particular. However the usual precautions used for chemical products should be respected.
PHOSPHORIC ACID: Incompatible with: metals, strong alkalis, aldehydes, organic sulphides, peroxides.
PHOSPHORIC ACID: May develop: phosphoryl oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal must be performed through an authorised waste management firm, in compliance with national and local regulations.
Reuse, when possible. Product residues should be considered special hazardous waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1805
- Shipping Name
- PHOSPHORIC ACID, SOLUTION
- Transport Class
- 8
- Packing Group
- III
Limited Quantities: 5 L
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SCL-255?
The signal word is danger.
What is the physical form of SCL-255?
SCL-255 is a liquid appearing as liquid with not available color. It has odourless odor.
What is the solubility of SCL-255?
completely soluble in water
What is SCL-255 used for?
Electrolyte to remove weld discoloration, clean, polish and passivate stainless steel with an electrolytic weld cleaner.
What are the hazard statements for SCL-255?
This substance has 1 hazard statement:
- H314: Causes severe skin burns and eye damage.
What is the melting point of SCL-255?
The melting point is Not available and the boiling point is Not available.