NextSDS Logo
Safety Data Sheet EN

Accelerator 748

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Accelerator 748

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial refractory application

Uses advised against

No information available

Manufacturers & Suppliers

G

Gouda Refractories

manufacturer

Goudkade 16 2802 AA Gouda The Netherlands

Emergency Contacts

Gouda Refractories

+31 (0)1825 91400

8.00- 17.00 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapors/spray
P280 Wear eye protection/ face protection
P285 In case of inadequate ventilation wear respiratory protection
P302 + P352 IF ON SKIN: Wash with plenty of soap and water
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Chemical Name CAS Number Concentration Hazardous
Aluminium orthophosphate EC: 232-056-9 --- 99% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh and dust free area

Skin contact

Wash skin with soap and water. Get medical attention if symptoms occur.

Symptoms: symptoms occur

Eye contact

Dust should be flushed with clean water. Contact lenses should not be worn with dust in the air IF IN EYES: Rinse cautiously with water for several minutes. Continue rinsing.

Ingestion

Rinse mouth. Not a normal way of entry. Drink large quantities of water and consult a doctor.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. If user operations generate dust, fumes or mist, use ventilation to keep exposure to airborne contaminants below the exposure limits.

Hands

No special protective equipment required. Protective gloves are recommended.

Eyes

Safety glasses with side-shields or goggles to prevent dust and particles from entering the eyes.

Respiratory

When workers are facing concentrations above the exposure limit (dust) they must use appropriate certified respirators.

Skin/Body

No special protective equipment required.

Environmental

Avoid dust formation

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Decomposition Temperature
---
State Under Standard Conditions
---
Odor
no smell
Form
Powder
Relative Density
---
Physical State Data
solid
Flammability
---
Lower Explosive Limit
---
Kinematic Viscosity
---
Partition Coefficient
---
Colour Intensity
---
Colour
White
Density
---
Appearance
White Powder with no smell
Molecular Weight
---
Physical State
White Powder
Vapor Density
---
Melting Point
>1500 C
Upper Explosive Limit
---
Ph
3 (10% solution 100 gram/l)
Crystallisation Point
---
Flash Point
Not applicable
Solubility
Soluble
Metal Corrosion
---
Dynamic Viscosity
---
Odor Threshold
---
Cloud Point
---
Properties Status
---
Softening Point
---
Auto Ignition Temperature
Not applicable
Evaporation Rate
---
Relative Evaporation Rate
---
Freezing Point
---
Bulk Density
800 kg/m³
Solubility In Water
Soluble
Solubility In Fat
---
Voc Content
---
Boiling Point
Not determine
Solidification Point
---
Vapor Pressure
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not regulated.
Shipping Name
Not regulated.
Transport Class
Not regulated.
Packing Group
Not regulated.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Accelerator 748?

The signal word is no signal word.

What is the physical form of Accelerator 748?

Accelerator 748 is a white powder appearing as white powder with no smell with white color. It has no smell odor.

What is the solubility of Accelerator 748?

Soluble

What is Accelerator 748 used for?

Industrial refractory application

What is the melting point of Accelerator 748?

The melting point is >1500 C and the boiling point is Not determine.