Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Pieri Top 01
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 0811-M0XH-K00D-V95P
Identified Uses
Construction Chemical.
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
GCP Produits de Construction SAS
manufacturer
ZA des Foulletons, 39140 Larnaud
+(33) 3 84 48 48 60
http://www.gcpat.com
Emergency Contacts
CHEMTREC
800-424-9300
CHEMTREC
+1 703-741-5970
CHEMTREC UK
+(44)-870-8200418
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
For further information, please refer to the product technical data sheet.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Glycerol EC: 200-289-5 | 56-81-5 | 10 - 20% | Yes |
| (+)-tartaric acid EC: 201-766-0 | 87-69-4 | 5 - 10% | Yes |
| Titanium dioxide EC: 236-675-5 | 13463-67-7 | 1 - 3% | Yes |
| Sodium 2-ethylhexyl sulphate | 126-92-1 | 1 - 3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
No special measures required.
Wash with plenty of soap and water.
Rinse cautiously with water for several minutes.
Rinse mouth. Do NOT induce vomiting.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Carbon dioxide. Fire-extinguishing powder.
No further relevant information available.
Firefighter Protection
Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Wear protective equipment. Keep unprotected persons away.
Inform respective authorities in case of seepage into water course or sewage system.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not eat, drink or smoke when using this product. Use only outdoors or in a well-ventilated area.
Store in a well-ventilated place. Keep container tightly closed. Protect from frost. Store in a dry place. Keep cool.
Do not eat, drink or smoke when using this product.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Protective gloves. EN 374. Material of gloves: Nitrile rubber. Nitrile rubber, NBR. Penetration time of glove material: The exact breakthrough time has to be determined by the manufacturer of the protective gloves and has to be observed.
Safety glasses with side shield protection. EN 166.
Control exposure to ingredients with workplace control parameters if mentioned above. If no ingredients are listed, respiratory protection is generally not required. If exposure limits are listed and may be exceeded, use approved respiratory protective equipment and filter type appropriate for the listed ingredients. (NIOSH, CEN, etc.). EN 143.
Use personal protective equipment as required. Take off contaminated clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
Stable under normal conditions. No further relevant information available.
No dangerous reactions known. No further relevant information available.
No further relevant information available.
No further relevant information available.
Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
Must not be disposed together with household garbage.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not Regulated
- Shipping Name
- Not Regulated
- Transport Class
- Not Regulated
- Packing Group
- Not Regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Pieri Top 01?
The signal word is danger.
What is the physical form of Pieri Top 01?
Pieri Top 01 is a liquid. with according to product specification. color. It has odourless. odor.
What is Pieri Top 01 used for?
Construction Chemical.
What are the hazard statements for Pieri Top 01?
This substance has 1 hazard statement:
- H318: Causes serious eye damage.
What is the melting point of Pieri Top 01?